• Your spa uses ground fault circuit interrupters in the electrical subpanel. Before each use of the spa and with the unit operating, push the

TEST button on each breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset each GFCI breaker by
switching it completely off and then completely on. The switch should then stay on. If either of the interrupters does not perform in this
manner, it is an indication of an electrical malfunction and the possibility of an electric shock. Disconnect the power until the fault has
been identified and corrected.
N

NO

OT

TE

E:: Failure to wait 30 seconds before resetting the GFCI may cause the spa’s Power Indicator (on the control panel) to blink. If this

occurs, repeat the GFCI test procedure.

DANGER: RISK OF ELECTRICAL SHOCK

• Install at least 5 feet (1.5 m) from all metal surfaces. A spa may be installed within 5 feet of a metal surface if each metal surface is

permanently connected by a minimum No. 10 AWG (6 mm

2

) solid copper conductor attached to the wire ground connector on the

terminal box that is provided for this purpose if in accordance with National Electrical Code ANSI/NMFPA70-1993.

• Do not permit any electrical appliances, such as a light, telephone, radio, or television within 5 feet (1.5 m) of a spa. Failure to maintain a

safe distance may result in death, or serious personal injury due to electrocution, if the appliance should fall into the spa.

• Install your spa is such a way that drainage is away from the electrical compartment and from all electrical components.

DO:

• Be sure your spa is connected to the power supply correctly - use a licensed electrical contractor.
• Disconnect the spa from the power supply before draining the spa or servicing the electrical components.
• Test the Ground Fault Circuit Interrupter(s) before each use.

DON’T:

• Use the spa with the equipment compartment door removed.
• Place electrical appliances within 5 feet (1.5m) of the spa.
• Use an extension cord to connect the spa to its power source. The cord may not be properly grounded and the connection is a shock

hazard. An extension cord may cause a voltage drop, which will cause overheating of the jet pump motor and motor damage.

• Attempt to open the electrical control box. There are no user serviceable parts inside.

RISKS TO AVOID

DANGER: RISK OF INJURY

• To reduce the risk of injury to persons, DO NOT remove suction fittings (filter standpipes) located in the filter compartment. 
• The suction fittings in the spa are sized to match the specific water flow created by the pump. Never replace a suction fitting with one

rated less than the flow rate marked on the original suction fitting.

• There is a danger of slipping and falling. Remember that wet surfaces can be very slippery. Take care when entering or exiting the spa.
• Never operate spa if the suction fittings are broken or missing.
• People with infectious diseases should not use the spa.
• Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving components. 

Increased side effects of medication

• The use of drugs, alcohol, or medication before or during spa use may lead to unconsciousness with the possibility of drowning.
• Persons using medications should consult a physician before using a spa; some medication may cause a user to become drowsy, while

other medication may affect heart rate, blood pressure, and circulation.

• Persons taking medications which induce drowsiness, such as tranquilizers, antihistamines or anticoagulants should not use the spa.

Health problems affected by spa use

• Pregnant women should consult a physician before using spa.
• Persons suffering from obesity, or with a medical history of heart disease, low or high blood pressure, circulatory system problems, or

diabetes should consult a physician before using spa.

Unclean water

• Keep the water clean and sanitized with correct chemical care. The recommended levels for your Hot Spring

®

spa are:

-  Free Available Chlorine (FAC):

3.0-5.0 ppm

-  Total Alkalinity:

125-150 ppm

-  Water pH:

7.4-7.6

-  Calcium Hardness: 150-200 ppm

(Refer to Water Quality and Maintenance section for complete instructions.)
IIM

MP

PO

OR

RT

TA

AN

NT

T::  Turn on the jet pump for a least ten minutes after adding ANY spa water chemicals into the filter compartment.

• Clean the filter cartridges monthly to remove debris and mineral buildup which may affect the performance of the hydromassage jets, limit

the flow, or trip the high limit thermostat, which will turn off the entire spa.

Safety Information

Содержание Hot Spring

Страница 1: ...Owner sManual...

Страница 2: ...____________ TELEPHONE ________________________________________________________________________________________________________________ SPA MODEL SERIAL NUMBER ________________________________________...

Страница 3: ...del AC 41 PRODIGY Model H 42 JETSETTER Model JJ 43 JETSETTER Model J 44 CONTROL PANEL OPERATIONS Control Panels 44 Main Control Panels 45 Indicator Lights 45 Locking Features 45 Main Control Panel But...

Страница 4: ...o reduce the risk of electrical shock replace a damaged cord immediately Failure to do so may result in death or serious personal injury due to electrocution Your spa is provided with a Ground Fault C...

Страница 5: ...verheating of the jet pump motor and motor damage Attempt to open the electrical control box There are no user serviceable parts inside RISKS TO AVOID DANGER RISK OF INJURY To reduce the risk of injur...

Страница 6: ...uch as 5 F 2 C Test the water with your hand before entering the spa to be sure it s comfortable SAFETY SIGN Each Hot Spring spa is shipped with a SAFETY SIGN in the owner s package The sign which is...

Страница 7: ...olt 50 amp Single phase GFCI protected circuit Jetsetter Model JJ 29 74 m 90 square feet 1 500 or 6 000 225 gallons 851 litres 450 lbs 204 kg 2 828 lbs 1 283 kg 90 lbs per square foot 115 volt 20 amp...

Страница 8: ...the spa on the ground even temporarily place stepping stones under the leveling areas see Spa Leveling Instructions The stones should be at least two inches thick and twelve inches square Even with st...

Страница 9: ...osite end resting on the lowest corner gently raise the lower end of the level by placing shims between the spa shell and the level until the level itself is level This will tell you how many shims ar...

Страница 10: ...sure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edge then center middle shims 21 1 4 54 cm 20 50 8 cm 20 50 8 cm 20 1 4 56 5 cm 89 226...

Страница 11: ...making critical design or pathway decisions 18 45 7cm 18 45 7cm 43 1 2 110 5cm 43 1 2 110 5cm 87 221cm 20 3 4 52 7cm 20 3 4 52 7cm 20 50 8cm 20 50 8cm 87 221cm 15 leveling points place shims approx 18...

Страница 12: ...Page 9 SOVEREIGN MODEL I II Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edg...

Страница 13: ...measure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edge then center middle shims 20 1 4 51 4 cm 16 5 8 42 3 cm 16 5 8 42 3 cm 20 1 4 5...

Страница 14: ...Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 10 leveling points place shims approx 15 in from edge then center middle shims I...

Страница 15: ...critical design or pathway decisions 10 leveling points place shims approx 15 in from edge then center middle shims Installation Instructions 84 2 13 m 80 2 03 m U P S I D E D O W N V I E W O F S P A...

Страница 16: ...Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 10 leveling points place shims approx 15 in from edge then center middle shims...

Страница 17: ...system lever B Moto Massage jet Comfort Control system lever C Precision jets Comfort Control system lever D Water feature lever E Hydromassage jet with directional nozzle F Hydromassage jet with rot...

Страница 18: ...ion jets K Soothing Seven jets L JetStream jet M Heater return and spa drain N Light lens O Filter compartment P Main control panel Q Auxiliary control panel R Water Feature Model GG only S Water Feat...

Страница 19: ...Precision jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary nozzle G Moto Massage DX jet H Precision jets I Soothing Seven jets J Je...

Страница 20: ...n jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary nozzle G Moto Massage jet H Moto Massage DX Jet I Precision jets J Soothing Seven...

Страница 21: ...ol system lever C Precision jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary nozzle G Moto Massage jet H Precision jets I Soothing S...

Страница 22: ...JetStream jet J Heater return and spa drain K Light lens L Filter compartment M Main control panel N Auxiliary control panel O Cup holder P Water feature Q Water feature lever 1 Wavemaster jet pump 2...

Страница 23: ...system lever B JetStream jet Comfort Control system lever C Precision jets Comfort Control system lever D Hydromassage jet with directional nozzle E Hydromassage jet with rotary nozzle F Precision jet...

Страница 24: ...JetStream jet Comfort Control system lever C Moto Massage DX jet Comfort Control system lever D Precision jets Comfort Control system lever E Pillow F Hydromassage jet with directional nozzle G Hydro...

Страница 25: ...jet Comfort Control system lever C Moto Massage jet Comfort Control system lever D Precision jets Comfort Control system lever E Pillow F Hydromassage jet with directional nozzle G Hydromassage jet w...

Страница 26: ...t of the control box Remove the screws and the control box cover 3 Route the electrical service from the subpanel into the spa equipment compartment Position the conduit in the recess provided between...

Страница 27: ...UE wire from the subpanel 20 amp breaker terminal L1 to TB 1 terminal 1 3 Connect the 12 AWG RED wire from the subpanel 20 amp breaker terminal L2 to TB 1 terminal 3 N NO OT TE E The WHITE neutral wir...

Страница 28: ...breaker switch to the ON up position If you don t wait 30 seconds the spa s control panel may flash four lines on and off try again If any of the GFCI breakers fails to operate in this manner your spa...

Страница 29: ...rs to place the program jumpers as shown in Figure 2 use Watkins P N 36021 N NO OT TE E The program jumpers JP 1 JP 2 and JP 3 must be set correctly for the spa to operate Figure 2 illustrates the cor...

Страница 30: ...tested prior to each use Here s how 1 Push the TEST button on each GFCI breaker and observe it click off 2 Wait 30 seconds then push the breaker switch to the OFF down position to ensure that it has c...

Страница 31: ...d the National Electric Code When the spa is installed the power cord will come out of the bottom of the equipment compartment door For your safety when the electrician is installing the 20 amp single...

Страница 32: ...ster 7000 jet pumps The Grandee GG uses one 2 0 HP Wavemaster 8000 and one 2 5HP Wavemaster 9000 single speed jet pump and the Envoy uses one 2 0 HP Wavemaster 8000 single speed and one 2 0 HP Wavemas...

Страница 33: ...et system and to purge any remaining air from the heating system push the JETS button for the Vista Grandee and Envoy push the JETS 1 and JETS 2 buttons push the JETS 2 button a second time on the Vis...

Страница 34: ...stem allows you to control the intensity of the massage at each jet by adjusting the mixture of air and water Jets with an adjustable faceplate are controlled by turning the faceplate clockwise for a...

Страница 35: ...jets located in the FootWell are not adjustable HYDROSTREAM JET VISTA ENVOY ACCOLADE JETSETTER JJ SPAS ONLY The Hydrostream jet is a mid size hydromassage jet that delivers a great massage to the feet...

Страница 36: ...onal Precision jets on right back wall 1 Moto Massage DX jet on right front 2 JetStream jets in FootWell system Jet Pump 2 Jet System 1 Right SmartJet lever in the 3 o clock position 6 HydroStream jet...

Страница 37: ...s on back wall 1 JetStream jet in FootWell System 2 directional Precision jets on left seat calf area Jet Pump 2 Jet System 2 Right SmartJet lever in the 9 o clock position 1 Moto Massage jet on right...

Страница 38: ...cision jets on left seat calf area 1 Moto Massage DX jet on right rear 4 directional Precision jets above right Moto Massage jet 2 directional Precision jets on right seat calf area Jet Pump 2 Jet Sys...

Страница 39: ...n left seat calf area 4 HydroStream jets on right back wall 1 Moto Massage DX jet on right front wall 1 JetStream jet in FootWell System Jet Pump 2 Jet System 1 Right SmartJet lever in the 3 o clock p...

Отзывы: