Color Coded Tubing-Standard Faucets

Tubing

Directions

1/4” Green

Feed water supply line to inlet. Feed ball valve labeled “TO FEED”

3/8” Blue

Carbon post filter elbow labeled “TO FAUCET” to center threaded shank of faucet

3/8” Yellow

Carbon post filter tee labeled “TO TANK” to ball valve on storage tank

1/4” Red

Flow restrictor labeled “TO DRAIN” to DS-EZW4 drain clamp.

INSTALLATION DIAGRAM FOR MILLENNIUM® RO SYSTEM 

(shown with standard faucet)

CONNECT YOUR SYSTEM TO THE COLD WATER SUPPLY ONLY. DO NOT USE A WATER 

SUPPLY THAT IS MICRO-BIOLOGICALLY UNSAFE, OR OF UNKNOWN SOURCE WITHOUT 

ADEQUATE DISINFECTION BEFORE OR AFTER THE MILLENNIUM® RO SYSTEM.

WARNING:

Cold Water

Feed Supply

JGV-ASVPP1LF

(Angled Stop Valve)

Sink

3/8” Blue Tubing

to Faucet

DS-EZW4

(Drain Saddle)

JGF-PP3212U7W

(Faucet Connector)

1/4” Green Tubing

Storage Tank

Stage 5: Carbon

Post Filter

Stage 4: TFC

Membrane

Stage 3: Carbon Block

Stage 2: Carbon Block

Stage 1: Sediment Pre�lter

1/4” Red Rubing

from Flow Restrict

to Drain Clamp

3/8” Yellow Tubing

to Tank

Содержание New Millennium

Страница 1: ...5 Stage Reverse Osmosis Drinking Water System with Booster Pump Installation Service Manual Assembled in USA...

Страница 2: ...phisticated machine We strongly recommend using only licensed experienced technicians for installation and troubleshooting To locate the closest authorised service technician contact your dealer or vi...

Страница 3: ...EM shown with standard faucet CONNECT YOUR SYSTEM TO THE COLD WATER SUPPLY ONLY DO NOT USE A WATER SUPPLY THAT IS MICRO BIOLOGICALLY UNSAFE OR OF UNKNOWN SOURCE WITHOUT ADEQUATE DISINFECTION BEFORE OR...

Страница 4: ...ILLENNIUM RO SYSTEM shown with optional air gap faucet CONNECT YOUR SYSTEM TO THE COLD WATER SUPPLY ONLY DO NOT USE A WATER SUPPLY THAT IS MICRO BIOLOGICALLY UNSAFE OR OF UNKNOWN SOURCE WITHOUT ADEQUA...

Страница 5: ...EFLON 5 Teflon Tape Used on all threaded fittings to prevent water leakage Eight rotations layers are adequate when using Teflon tape to secure any threaded fittings The Millennium RO already has Tefl...

Страница 6: ...he 3 8 flex line from the base of cold water basin supply angle stop valve 4 Re connect the 3 8 JGV ASVPP1LF Angle Stop Valve to the basin supply angle stop valve 5 Re connect flex line to the JGV ASV...

Страница 7: ...t stud will be accessible from below once the whole is completed 8 For Porcelain Sink Before starting the drill motor apply firm downward pressure on the bit until a crunching occurs This will help ke...

Страница 8: ...cet connector MOUNTING THE FAUCET Standard Faucet 1 Drill a hole in the sink or the counter top or use an existing hole 2 Slide chrome cover plate and rubber gasket on to stem of faucet and place fauc...

Страница 9: ...ng on screws 2 The storage tank may be laid on its side The bladder tank will function in both a horizontal or vertical position 3 The head assembly and or storage tank may be placed up to 10 feet fro...

Страница 10: ...le the o ring provides a permanent leak proof seal 3 Push up to tube stop Fitting grips before it seals Ensure tube is pushed into the tube stop 2 Insert tube Cut the tube square It is essential that...

Страница 11: ...available 8 During this initial fill period you will hear water being discharged through the red drain line This is normal as the contaminated water is being rejected by the reverse osmosis membrane T...

Страница 12: ...supply to the system 2 Close storage tank ball valve 3 Open the dispensing faucet to depressurize the system Allow 2 to 3 minutes 4 Remove the filter housings by turning counter clockwise 5 Remove old...

Страница 13: ...thoughTFCmembranesaredesignedfornonchlorinatedfeedsupply yourMillennium ROsystemis equippedwithdoublecarbonpre filtrationforchlorinereductionpriortotheTFCmembrane Stage 5 Carbon filter This Post filte...

Страница 14: ...BLADDER IN TANK IS RUPTURED TANK MUST BE RE PLACED WITH NEW ONE 5 CHECK VALVE ON PRODUCT SIDE NOT HOLDING 1 REPLACE CHECK VALVE ON UNIT SLOW PRODUCTION 1 LOW WATER PRESSURE 1 MAKE SURE PUMP IS WORKIN...

Страница 15: ...h the use inability to use or performance of the Millennium system Millennium is not responsible or liable for damage to any part of the Millennium system because of misuse misapplication negligence a...

Страница 16: ...Assembled in USA...

Отзывы: