BATHTUB AND DRAIN INSTALLATION:
(continued)
➢
Pre-drill the tile flange on the centers of each framing stud. Secure the
tub to the wall using drywall screws or galvanized roofing nails.
(DO NOT OVERTIGHTEN)
➢
Fill the tub with water to the overflow and then drain while inspecting the
waste connections below the floor for leaks. Access from below the floor
will be necessary for this step.
➢
Run a bead of tub and tile caulk around the bottom edge of the bathtub
where it meets the finished floor. Wipe away any excess caulk with a wet
paper towel.
➢
Cover the bathtub surface with a bathtub liner or other form of
protection until construction is completed.
➢
If further assistance is required, please contact Product Support at1-800-
927-2120 (8am-7pm EST).
ELECTRICAL REQUIREMENTS:
➢
Airtub Blower: 120 volt / 15 amp GFCI protected, dedicated line.
➢
To test the GFCI, do the following: (1) Plug power cord(s) into electrical
outlet (2) Push the test button; check that the power has been
interrupted, and (3) Push to reset button; check that the power has been
restored.
➢
IF THE GFCI DOES NOT OPERATE PROPERLY DURING THE TEST,
THERE IS A GROUND CURRENT FLOWING, WHICH INDICATES
THE RISK OF ELECTRICAL SHOCK.
DO NOT USE THE BATHTUB, DISCONNECT THE BATHTUB
IMMEDIATELY AND HAVE THE POWER SOURCE SERVICED BY
QUALIFIED PERSONNE.L.
CLEAN-UP AFTER INSTALLATION:
➢
When cleaning up after installation, do not use abrasive cleaners as they
may scratch and dull the surface. Use warm water and a liquid non-
abrasive detergent to clean the surface.
➢
Stubborn stains, paint, or tar can be removed with turpentine based
cleaner such as “Goof Off ”. Do not allow cleaners containing petroleum
distillates to remain in contact with the bathtub surface for long periods
of time. Plaster can be removed by scraping with a wood edge. Do not
use metal scrapers, wire brushes, or other metal tools. One of the
powder-type detergents may be used on a damp cloth to provide mild
abrasive action to remove the residual plaster.
TESTING SYSTEM OPERATION:
➢
Remove all debris and residue before filling th tub with water.
➢
Fill the tub with water approximately halfway and examine the tub and
system carefully for leaks.
➢
Check all three functions of the airtub system in accordance with the
operating instructions.
➢
Allow water to sit for 10 minutes and check for leaks.
➢
Open drain, empty tub, and wipe up excess water with a soft damp
sponge.
TECHNICAL SERVICE:
➢
Read the product identification tag (located on bathtub near blower).
This tag includes all pertinent information specific to your product,
including the model, size, date of manufacture and ID number.
➢
Have information available when contacting Waterworks Product
Support at 1-800-927-2120 (8am - 7pm EST).
OPERATING INSTRUCTIONS:
Controlled by 3-function control pad.
➢
On/off function, first touch turns on the system, second touch turns off
the system.
➢
Speed function, first touch increases the rate of bubbles, second touch
decreases the rate of bubbles.
➢
Pulsating function, first touch starts slow pulsating cycle, second touch
starts quick pulsating cycle, third touch turns off pulsating cycle.
A 30 second dying cycle will automatically start 20 minutes after the air system
is turned off or the sensor has detected that there is no more water
remaining in the bathtub.
WARNINGS:
The following basic safety precautions should always be followed when
using your bathtub.
➢
CAREFULLY READ AND FOLLOW ALL INSTRUCTIONS BEFORE
ATTEMPTING TO OPERATE YOUR BATHTUB.
➢
Caution should always be exercised when entering or leaving the
bathtub.
➢
DANGER:To reduce the risk of injury, do not permit children or persons
with a disability to use this unit unless they are closely supervised at all
times.
➢
This product is intended for indoor use only. Use the bathtub only for its
intended purpose and do not use attachments or accessories that are
not recommended by the manufacturer.
➢
Never drop or insert any objects into any openings.
➢
The bathtub must be connected to an electrical supply circuit that is
protected by a ground fault circuit interrupter (GFCI), which is provided
by the installer.The GFCI should be tested periodically to ensure that it is
working properly.
➢
Keep all electrical appliances, such as radios and hairdryers, a safe distance
from the bathtub.
➢
Failure to comply with all instructions, requirement, and warnings
contained in this manual create a serious hazard to the bathtub user and
may result in serious personal injury.
➢
Do not use the bathtub when sleepy or drowsy, under the influence of
alcohol or prescription medications, or when overheated. Pregnant
women and persons with medical conditions should consult their
physicians for advice before use.
Care and Warranty
W A T E R W O R K S
Empire Corner Air tub And Drain Assembly
Save These Instructions.