P o w e r   D e f e n d e r   1 4 0   f o r   W a t e r w a y   P o o l   P u m p   M o t o r  

 

I n s t a l l a t i o n   a n d   O p e r a t i o n   M a n u a l

 

22

 

Timers 1 

 7 

One of the key advantages of the Power Defender 140 for Waterway is the flexibility of customizing 
up to seven Timers. The Timers control when the pump switches on and off throughout the day. You 
can customize the 

Start Time

Duration

, and 

Speed

 for each. Control logic begins at the speed with 

the earliest start time of the day and continues running that speed until the next start time of day is 
reached. If the timer schedule is configured in such a way that run times overlap, the timers run in 
priority from Timer 1 (highest) through Timer 7 (lowest). The default schedule is as follows: 

Timer # 

Start Time 

Duration 

Speed 

Timer 1 

8:00 AM 

2 Hours 

3450 RPM 

Timer 2 

10:00 AM 

10 Hours 

1400 RPM 

Timer 3 

8:00 PM 

2 Hours 

2200 RPM 

Timer 4* 

12:00 AM 

0 Hours 

1000 RPM 

Timer 5* 

12:00 AM 

0 Hours 

1000 RPM 

Timer 6* 

12:00 AM 

0 Hours 

1000 RPM 

Timer 7* 

12:00 AM 

0 Hours 

1000 RPM 

*By default, Timers 4 

 7 are deactivated. A 

Duration

  

of 

0

 deactivates a Timer. 

To program a Timer, press the 

MENU/ENTER

 button once to enter 

Navigation Mode

. Press 

Scroll 

Up

 or 

Scroll Down

 to select the 

Custom Settings

 menu tree. Press 

MENU/ENTER

 to enter the 

menu tree. Press 

Scroll Down

 until you reach the Timer you want to program. Press 

MENU/ENTER

 

again to enter 

Input Mode

. The following example uses 

Timer 1

. The process is the same for each. 

 

On the Timer Start screen, press the 

MENU/ENTER

 button to enter 

Input Mode

. Press 

Scroll Up

 to 

increase the hour or 

Scroll Down

 to decrease the hour. Press

 MENU/ENTER

 to cycle the edit field 

to the right. Press 

Scroll Up

 to increase the minutes or 

Scroll Down

 to decrease the minutes. Press 

MENU/ENTER

 to save the changes. Press 

START/PAUSE

 to exit the menu option and return to the 

menu tree in 

Navigation Mode

. Press 

START/PAUSE

 again to return to normal operations. 

 

Press 

Scroll Down

 until you reach the screen for the Timer Duration. Press the 

MENU/ENTER

 

button to enter 

Input Mode

. Press 

Scroll Up

 to increase the hour or 

Scroll Down

 to decrease the 

hour. Press 

MENU/ENTER

 to cycle the edit field to right. Press 

Scroll Up

 to increase the minutes or 

Scroll Down

 to decrease the minutes. Press 

MENU/ENTER

 to save the changes. Press 

START/PAUSE

 to exit the menu option and return to the menu tree in 

Navigation Mode

. Press 

START/PAUSE

 again to return to normal operations. 

 

Press 

Scroll Down

 until you reach the Timer Speed screen. Press the 

MENU/ENTER

 button to 

enter 

Input Mode

. Each press of the 

Scroll Up

 button increases the RPM in increments of 10. 

Likewise, each press of the 

Scroll Down

 button decreases the RPM in increments of 10. Press and 

hold the 

Scroll Up

 button continuously increases the RPM in increments of 100. Press and hold the 

Scroll Down

 button continuously decreases the RPM in increments of 100. Press 

MENU/ENTER

 to 

save the changes. Press 

START/PAUSE

 to exit the menu option and return to the menu tree in 

Navigation Mode

. Press 

START/PAUSE

 again to return to normal operations. 

Содержание Power Defender 140

Страница 1: ...l Power Defender 140 for Waterway Programmable Pool Pump Motor Control This product does NOT provide a Safety Vacuum Release System SVRS Save this instruction manual for future reference Part M0183168...

Страница 2: ...9 Motor Protections 11 Low Temperature Monitor 11 Motor Stalled 11 Open Output Phase 11 Output Over Current 11 Output Over Power 11 Power Module Temperature 11 Under Voltage 11 Hardware Protection 12...

Страница 3: ...rotect personnel from possible injury Personnel should be instructed for handling each of the following Only apply nameplate voltage 115 or 230 with the Voltage Selection Switch in the correct positio...

Страница 4: ...to the motor terminal block Care must be taken to assure connections are made to the proper terminals and adequate electrical clearances are maintained The control unit on the motor contains hazardous...

Страница 5: ...ariable speed Voltage Hertz Single phase 115 and 230 Vac 50 or 60 Hz Speed Range 600 3450 RPM Efficiency 80 at 3450 RPM Enclosure Finned Aluminum enclosure providing a Water Ingress Protection level o...

Страница 6: ...n d e r 1 4 0 f o r W a t e r w a y P o o l P u m p M o t o r I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l 4 Dimensions Square Flange All dimensions are for reference only Side View Fa...

Страница 7: ...d e r 1 4 0 f o r W a t e r w a y P o o l P u m p M o t o r I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l 5 Dimensions Thru Bolt with Base All dimensions are for reference only Side View...

Страница 8: ...tions up to 10 percent of the nominal value Line Input 1 Minimum Operating Voltage Minimum Full Performance Voltage Maximum Operating Voltage 115 Vac 104 Vac 104 Vac 127 Vac 230 Vac 207 Vac 207 Vac 26...

Страница 9: ...ed motor UL1081 approvable Standard for Safety Swimming Pool Pumps Filters and Chlorinators UL 1004 1 Standard for Rotating Electrical Machines General Requirements UL 1004 7 Standard for Electronical...

Страница 10: ...control from the sun Provide ample cross ventilation Protect the motor control from lint etc which can clog the ventilation openings Protect against Dirt Keep the motor control and the surrounding ar...

Страница 11: ...the motor contains hazardous voltage 1 Remove the four 4 slotted head hex washer screws securing the Wiring Compartment Cover Set the cover aside 2 Remove the three 3 slotted head hex washer screws s...

Страница 12: ...ment 6 Insert the power cable and use a water tight connector to seal the conduit hole 1 2 NPT thread 7 Install the AC and Ground input wires as specified on the motor nameplate You must connect Line...

Страница 13: ...he three phase lines between the motor and control is not connected well the output voltage in the control is not able to reach the motor The motor cycles through the shutdown restart sequence the num...

Страница 14: ...Voltage input power Low Voltage control inputs The High Voltage Compartment has a separate cover The High Voltage Compartment is supplied with a threaded hole for 1 2 NPT conduit connection for use wi...

Страница 15: ...Mode there is no response Likewise in Input Mode there is no response In Run Mode force an override using the pre assigned Speed 2 default RPM MENU ENTER When the UI is unlocked in Navigation Mode ent...

Страница 16: ...o t o r I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l 14 Quick Start Guide The Power Defender 140 for Waterway Variable Speed Pool Pump Motor ships with a Quick Start Guide on the insid...

Страница 17: ...ations In Run Mode or Standby Mode the three Speed buttons and Clean execute as follows Button Description Speed 1 Force an override speed of 1350 RPM 40 Speed 2 Force an override speed of 1725 RPM 50...

Страница 18: ...tion The LCD screen displays the following message for two 2 seconds and then returns to normal operation Operational States The table below describes the operational states for the motor State Descri...

Страница 19: ...Press Scroll Up or Scroll Down to cycle between Standard Settings and Custom Settings Press the MENU ENTER button a second time to enter the top level menu you selected Press the START PAUSE button to...

Страница 20: ...p e r a t i o n M a n u a l 18 Custom Settings Configuration options under Custom Settings allow you to program the Start Time Duration and Speed of each Timer You can program up to seven The followin...

Страница 21: ...the 24H or AM PM screen Press MENU ENTER again to enter Input Mode Press Scroll Up or Scroll Down to toggle the selection Press MENU ENTER to save the changes Press START PAUSE to exit the menu optio...

Страница 22: ...for 30 minutes at 30 of the rated speed of the motor The pump then idles for 30 minutes If at the end of 30 minutes the temperature is still below the low temperature threshold the cycle repeats itse...

Страница 23: ...he operation of the motor Note This option is not available unless the Remote Control setting above is Enabled The Node ID can be set to any number between 1 and 247 The default number is 240 Also a D...

Страница 24: ...process is the same for each On the Timer Start screen press the MENU ENTER button to enter Input Mode Press Scroll Up to increase the hour or Scroll Down to decrease the hour Press MENU ENTER to cyc...

Страница 25: ...pre programmed RPM assigned to the button for the remaining duration of the flow Note Pressing the START PAUSE button will pause the motor This action also cancels the override Pressing START PAUSE ag...

Страница 26: ...rtment 3 Attach the cable to the RS485 Connector to the interface board The 3 position DIP Switch on the interface board can be used to identify a specific MODBUS ID A DIP Switch ID other than zero 0...

Страница 27: ...s in accordance with the applicable codes and ordinances in your area and in accordance with the NEC All electrical connections should be made and maintained by a qualified or licensed electrician Alw...

Страница 28: ...verify that the pump rotates freely Low voltage Verify that the motor voltage under load to the conduit box connection terminals matches the nameplate voltage requirements Breaker trip The interruptio...

Страница 29: ...the fault has not corrected itself the motor will not restart The fault condition can be triggered by the motor the control or the pump system Press the Start Pause button to clear the fault from the...

Страница 30: ...ifying the wire connections contact your pool professional or a qualified electrician for service E 8 MC EE Error Self Clearing No Retry Count 50 Retry Delay 12 Seconds User Reset Yes This fault indic...

Страница 31: ...a qualified electrician for service E 16 Motor Stalled Self Clearing No Retry Count 50 Retry Delay 12 Seconds User Reset Yes This fault indicates that the rotor is locked When the software detects a l...

Страница 32: ...osts Your electric bill is based on the number of Kilowatts used in a typical billing cycle Each Kilowatt is 1 000 watts To calculate how much energy your current pool motor is using and to calculate...

Страница 33: ...Minutes Priming Speed 2850 RPM Temp Unit F Low Temp Monitor Disable Low Temp Monitor 37 F Remote Control Disable Node ID 240 Numeric Reset To Factory Custom Settings Value Units Timer 1 Start 8 00 AM...

Страница 34: ...P o w e r D e f e n d e r 1 4 0 f o r W a t e r w a y P o o l P u m p M o t o r I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l 32...

Страница 35: ...ctions or applicable codes If within thirty 30 days after Purchaser s discovery of any warranty defects within the above stated warranty period Purchaser notifies NMC or the dealer from whom the motor...

Страница 36: ...rway Plastics All rights reserved Waterway is a trademark of Waterway Plastics For more information 2200 East Sturgis Road Oxnard California 93030 Phone 805 981 0262 FAX 805 981 9403 https waterwaypla...

Отзывы: