Installing Jumpers for a 2-Speed Pump
To install a 2 speed pump you must use the left two relays. Three
jumpers need to be installed:
Jumper 1 – Line 1 from Relay 1 to Line 1 of Relay 2.
Jumper 2 – Line 2 from Relay 1 to Line 2 of Relay 2.
Jumper 3 – Load 2 from Relay 1 to Load 2 of Relay 2.
5.3.3
Installing Variable Speed
Filter Pump
Connect power to the “Filter Pump” relay 1 (see Figure 10.2)
NOTE:
Variable Speed Pumps not manufactured by Waterway
Plastics should be connected directly to the breaker.
12
5.3
Install Filter Pump
5.3.1
Installing a 1-Speed Filter Pump
Install Single Speed Pump – relay 1 plug into the connector labeled
“Filter Pump” (see Figure 9)
- For 240V from power source
connect “Lines” to Relay 1 Line 1
and Relay 1 Line 2.
- Connect “Load” to Relay 1 Load 1
and Relay 1 Load 2 (see Figure 3).
For wiring diagram refer to Figure 10)
Figure 10. Relay Sequence & Plug-In
Figure 9. Relay Connections
5.3.3.1
Installing Communication Cable
for Variable Speed Pump
Select the correct pump manufacturer and model from Installer
Setup. Connect the Communication cable to the OASIS variable
speed connection terminal as shown below. (Figure 10.3)
When using Installer Setup to configure the OASIS Pool Controller
for a Variable Speed pump it is important to select the correct pump.
WWVSP = Power Defender 165 & Power Defender 270
WWVSP2 = Power Defender 300
Intel VSP = Pentair IntelliFlo pumps
Hayward VSP = select Hayward EcoStar VS pumps
Jandy VSP = select Jandy Pro Series VS pumps
Refer to Figure 11- Figure 13 for specific wiring information
The color code and order of connections varies based on the pump
manufacturer and model as shown in the following pictures.
RELAY PLUG-IN
FILTER PUMP
AUX 1
AUX 2
AUX 3
AUX 4
AUX 5
RELAY SEQUENCE AND PLUG-IN
RELAY 1
FILTER
RELAY 2
RELAY 3
RELAY 4
RELAY 5 RELAY 6
PUMP
AUX 1
AUX 2
AUX 3
AUX 4
AUX 5
Filter Pump
Breaker Box
VARIABLE SPEED CONNECTION
Left to Right Wiring
1
2
3
4
Figure 10.3
Figure 10.2. Relay Sequence & Plug-In
RELAY SEQUENCE AND PLUG-IN
RELAY 1
FILTER
RELAY 2
RELAY 3
RELAY 4
RELAY 5 RELAY 6
PUMP
AUX 1
AUX 2
AUX 3
AUX 4
AUX 5
Filter Pump
Breaker Box
LINE 1
LO
AD 1
LINE 2
LO
AD 2
5.3.2
Installing a 2-Speed Filter Pump
Install Two Speed pump – Pump High needs to plug into relay
connector label “Filter Pump” and Low needs to plug relay into
connector labeled “Aux 1”
- For 240V from power source connect “Lines” to Relay 1, Line 1
and Relay 1, Line 2 on. Aux 1 relay connect power source to line 1
(see Figure 3 and Figure 10.1 – page 11)
RELAY SEQUENCE AND PLUG-IN
NOTE:
Waterway does not assume responsibility for software changes by other pump
manufacturers.