810-4800.1017
©2017 Waterway Plastics
To ensure proper water flow:
• Use rigid PVC pipe with a minimum diameter of 3/4”, (1-1/2” is recommended) for the dedicated return line. Flexible PVC piping is not
recommended as it can be damaged by expansion and movement caused by the surge of pump pressure.
• The booster pump inlet connection line should be at least 3/4” pipe. The supplied 3/4” barb fitting is designed to work with the Waterway
supplied reinforced hose.
• Do not tap into the top of a horizontal line.
Installing the Pump
1. Mount the pump using two concrete expansion anchors to ensure stability.
2. Install supplied 3/4” barb fitting onto pump discharge and supply ports using Teflon® tape as sealant.
3. Measure and cut reinforced hose ensuring cut is clean, with no more than a 30º off straight edge.
4. Push the hose onto the hose barbed fitting until it is flush against the hose barb base. Secure the hose with supplied hose clamps.
Typical Installation
Pool Pump
From
Pool
To
Pool
Filter
Heater
To Spa
Booster
Pump
Solar
System
Plumbing
Options
1, 2 or 3
Chlorinator
Cleaner
Minimum of 3 Feet
Note:
Plumb the Booster Pump upstream
of all air inducing equipment
Recommended Configurations
A.
(Preferred)
B.
Horizontal
Leg
Pool Return
Ground Level
From Filter or Heater
Option 1
Street Ell
Waterway
Reinforced
Hose
To Booster
Pump
To Spa
Pool Return
To Spa
Leave
6”
Ground Level
Option 2
Option 3
From Filter or Heater
Barb Fitting, Hose Clamp and Hose - Assembly
Complete Installation