background image

640-231X V  MAIN DRAIN OWNER’S MANUAL

WARNING - SUCTION ENTRAPMENT HAZARD

Suction in suction outlets and/or suction outlet 
covers which are damaged, broken, cracked, 
missing, or unsecured can cause severe injury and/

or death due to the following entrapment hazards:

Hair Entrapment:

  Hair can become entangled in suction outlet cover.

Limb Entrapment:

  A limb inserted into an opening of a suction outlet 

sump or suction outlet cover that is damaged, broken, cracked, missing, 
or not securely attached can result in a mechanical bind or swelling of 
the limb.

Body Suction Entrapment:

  A negative pressure applied to a large 

portion of the body or limbs can result in an entrapment.

Evisceration / Disembowelment Entrapment:

  A negative pressure 

applied directly to the intestines through an unprotected suction 
outlet sump or suction outlet cover which is damaged, broken, cracked, 
missing, or unsecured can result in evisceration / disembowelment 
entrapment.

Mechanical Entrapment:

  There is potential for jewelry, swimsuit, 

hair decorations, finger, toe, or knuckle to be caught in an opening of a 
suction outlet cover resulting in mechanical entrapment.

USE ONLY GENUINE WATERWAY REPLACEMENT PARTS.

IMPORTANT SAFETY INSTRUCTIONS

For Part Numbers:   640-2310 • 640-2311 • 640-2312 • 640-2317 • 640-2319-DKG • 640-2319-BEI • 640-2319-DKB

810-0046.0121

©2021 Waterway Plastics

2200 East Sturgis Road, Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403

www.waterwayplastics.com • [email protected]

Designed,

Engineered & 

Manufactured 

in the USA.

Read and follow all instructions in this owner’s manual and on the equipment. Failure to follow instructions can cause 

severe injury and/or death.

WARNING:

VGBA

2017

IMPORTANT SAFETY INSTRUCTIONS. READ, UNDERSTAND, AND FOLLOW ALL WARNINGS  

AND INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

SOFA INSTRUCTIONS

When installing and using this equipment, basic safety precautions shall always be followed, including the following: IMPORTANT 
SAFETY INSTRUCTIONS. READ, FOLLOW, AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS.

Any modification that increases the flow rate of the circulation system shall require re-evaluation of the cover/grate and sump to 

ensure that the flow rating of the Suction Outlet Fitting Assembly (SOFA) is not exceeded.

Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA component shall be replaced before bathers are 

allowed to use the pool.

Loose cover/grates shall be reattached before bathers are allowed to use the pool.

SAVE THESE INSTRUCTIONS.

Содержание 640-231 V Series

Страница 1: ...ENUINE WATERWAY REPLACEMENT PARTS IMPORTANT SAFETY INSTRUCTIONS For Part Numbers 640 2310 640 2311 640 2312 640 2317 640 2319 DKG 640 2319 BEI 640 2319 DKB 810 0046 0121 2021 Waterway Plastics 2200 Ea...

Страница 2: ...tion cover for service or winterization using a Phillips head screw driver remove the screws Inspect both the suction cover and suction fitting for any cracks or damages Any and all broken or missing...

Страница 3: ...ter For winterization remove the cover and plug the inlet Use screw driver for service and removal of fasteners Observe cover grate fasteners for damage each operational day During installation ensure...

Страница 4: ...2 3 1 819 00801 642 215x V 642 214x 2 3 1 819 00801 642 215x V SG642 214x 640 2310V SG6402310...

Страница 5: ...SUMP DUAL PORT 3 1 2 672 2510 642 215x V 819 00801 4 715 9910 GRATED ANTI VORTEX CONCRETE ASSEMBLY 1 Align cover holes with brass inserts 2 Hand tighten supplied screws DO NOT USE POWERTOOLS 3 A mini...

Страница 6: ...COLLAR SUMP DUAL PORT 5 4 3 1 2 819 00801 642 215x V 642 2240 715 9910 672 2550 GRATED ANTI VORTEX CONCRETE ASSEMBLY 1 Align cover holes with brass inserts 2 Hand tighten supplied screws DO NOT USE PO...

Страница 7: ...RATED ANTI VORTEXVINYL LINER ASSEMBLY 1 Install rubber gasket to body by pushing in raised alignment cups into slots in body see Diagram A 2 Lay vinyl liner over main drain 3 Put fiber gasket and moun...

Страница 8: ...DEEP SUMP DUAL PORT 3 4 1 2 819 00801 642 215x V 715 9930 672 2610 GRATED ANTI VORTEX CONCRETE ASSEMBLY 1 Align cover holes with brass inserts 2 Hand tighten supplied screws DO NOT USE POWERTOOLS 3 A...

Страница 9: ...LLAR DEEP SUMP DUAL PORT 4 5 3 1 2 819 00801 642 215x V 642 2240 715 9930 672 2650 GRATED ANTI VORTEX CONCRETE ASSEMBLY 1 Align cover holes with brass inserts 2 Hand tighten supplied screws DO NOT USE...

Страница 10: ...642 2150 V 4 FLOW PATH 8 FLOW PATH POOL STRUCTURE FINISH SURFACE OF THE POOL FIELD BUILT DEEP SUMP WITH 2 5 PIPE SECTION A A A A SECTION A A 2 SOC 2 SOC 642 215X V 5 25 FLOW PATH 4 FLOW PATH FINISH S...

Отзывы: