Enter the Installer Screens by pressing and holding
+
simultaneously for for
3-5 seconds.
Once the display changes, press until you reach the “Regeneration Time” display.
When on the “Regeneration Time” display, use or to adjust the hour. The hours will
cycle through AM and PM.
Press to move the cursor to adjust the minutes. Use or to adjust the minutes.
Advance to the next Installer Screen by pressing OR you can return to the home display
by pressing
3
STARTING UP THE SYSTEM
STEP 1.
Make sure the system is in the “Bypass” position before turning the main water
back on. See page 9.
Make sure the drain line provided is connected securely to the control valve and is properly
located over a drain.
Make sure the control valve is plugged into an operating outlet with the correct voltage and is
properly grounded.
STEP 2.
Press and hold the REGEN button on the Triton Valve until you hear the motor
engage. This will initiate an immediate manual regeneration of the system. Turn the bypass
valve to "diagnostic" mode position (see figure 3 on page 9). The screen will indicate
“BACKWASH”. You should hear water entering the system. Wait a few minutes to ensure the
control valve can draw water and does not leak. Let the tank fill and begin to push water out
the drainline. Allow the system to backwash until the water going to drain is clear. If
everything is working, press and release the REGEN button. You will hear the motor engage
and move the piston into the “RINSE” position. Again, check for leaks anywhere on the
tank/valve or connections. Allow valve to continue pushing water to the drainline until the
water coming out of drainline is clear. After a few minutes, you will hear the motor engage
and move the piston into the “SERVICE” position. If the water coming out of the drainline is not
clear by the end of the above cycles, repeat Step 2 above with bypass in “diagnostic” position.
STEP 3.
If water to drain is completely clear, turn bypass valve to "normal" operation
position (see figure 1 on page 9). Let the water in the taps of the building run for several
minutes to purge the unconditioned water out of the pipes.
FLUSHING AND CONDITIONING
Did you connect the drain
line securely to the valve?
YOUR SYSTEM IS READY FOR OPERATION