WaterTech INF-GUARD1 Скачать руководство пользователя страница 10

WATER FILTER SYSTEMS

 

NAME AND  

PART NUMBER

SIZE &  

MICRON RATING

CHLORINE/CHLORAMINE  

TASTE AND ODOR REDUCTION CAPACITY (*)

PRESSURE DROP SPEC

Infinity Sentinel

INF-SEN1

8” x 40”, 3.0

Nominal 3 micron rated filter to treat >250,000 gallons (946,353 Liters) of water @ 15 gpm (56.78 

LPM) with greater than 90% reduction, estimated capacity using 2ppm of free chlorine.

5 psid @ 15 GPM

Infinity Guardian

INF-GUARD1

8” x 40”, 3.0

 Nominal 3 micron Chloramine rated filter to treat >50,000 gallons (189,271 Liters) of water @ 7 

gpm (26.50 LPM) with greater than 85% reduction, estimated capacity.

5 psid @ 15 GPM

*Claims are not performance tested by IAPMO or NSF. Performance claims are based on independent laboratory and manufacturer’s internal test data.

Actual performance is dependent on influent water quality, flow rates, system design and application. Results may vary.

This pressure vessel is tested and certified  

by NSF International against NSF/ANSI 

Standard 44 and 61 for materials and 

structural integrity requirements

SPECIFICATIONS

IMPORTANT

 

DO NOT USE extra lubricants, unapproved sealants and tools to 

tighten hand tightened only parts. Use of tools other than hand 

tighten only parts voids warranty. Flush the system and change the 

filter as suggested. The contaminants or other substances removed 

or reduced by this water filter are not necessarily in all users’ water. 

 

Filter Replacement Operating Instructions: New cartridges must 

be flushed for a minimum of 10 minutes prior to use. System and 

installation to comply with state and local laws and regulations. 

Do not use with water that is microbiologically unsafe or unknown 

quality without adequate disinfection before or after the system. 

Manufactured from NSF/ANSI standard 61 and California Prop 65 

Compliant certified coconut shell carbon and raw materials.

Содержание INF-GUARD1

Страница 1: ...INSTALLATION OPERATION MANUAL MODEL INF GUARD1 MODEL INF SEN1...

Страница 2: ...d to be used on municipally treated water sources Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or after the system Filter usa...

Страница 3: ...INSTALLATION OF INFINITY WHERE TO INSTALL 1 CITY WATER INLET WATER METER SERVICE SERVICE WELL INLET RELIEF VALVE MUST BE INSTALLED PRESSURE TANK PUMP WELL WATER CITY WATER...

Страница 4: ...ilter INF SEN1 FX OR INF GUARD1 FX DRAIN VALVE IMPORTANT Bypass Orientation INLET OUTLET Flow direction arrows on bypass are incorrect for this filter application Plumb unit opposite of arrows 6 10 11...

Страница 5: ...n NOT PROVIDED STEP 4 OPTION B Use 7 90 degree Angled In Out 1 MNPT for connecting your plumbing to the system HAND TIGHTEN ONLY STEP 5 Install part 4 into 3 using the threaded connection Teflon tape...

Страница 6: ...g should slide completely out of the groove STEP 5 Remove packaging from filter cartridge then place the filter cartridge into the tank with the double O ring facing down STEP 8 Reposition the Top Cap...

Страница 7: ...OTE Due to unknown water quality and water usage it is recommended to replace filter annually for a household of 4 people 1 SENTINEL Filter Replacement Part Number INF SEN1 FX GUARDIAN Filter Replacem...

Страница 8: ...d John Guest fitting and shut off that connects to the inlet side of the filtration system Run the hose to a floor drain or bucket and use to drain sediment or to aid in filter removal during change o...

Страница 9: ...down until all the air pressure is completely released and water comes out of the red depressurization button STEP 21 Check for leaks STEP 13 Reposition the Top Cap into its original location STEP 16...

Страница 10: ...design and application Results may vary This pressure vessel is tested and certified by NSF International against NSF ANSI Standard 44 and 61 for materials and structural integrity requirements SPECI...

Страница 11: ...onal users 7 THIS WARRANTY EXCLUDES THE FOLLOWING a Damage caused by improper installation operation or care b Damage caused by chemical attack environment accident fire flood freezing Act of God misu...

Страница 12: ...WaterTech 800 Freeport Pkwy 150 Coppell TX 75019 469 521 1180 CustomerSupport WaterTech com www WaterTech com...

Отзывы: