13

 

 

                                                                                                                                                   

                                                                                                                                         

 

 

                                                                                                                                                   

                                                                                                                                         

Normal Operation

1. 

Home Display

       

a. 

Time Clock Softeners -

Alternates between the display of Time of Day and Number of  Days until the

                 Next Regeneration. 
 

 

- Days Remaining until the Next Regeneration will count down from the entered value until it 

                            reaches 1 day remaining.
 

 

- A Regeneration Cycle will then be initiated at the next designated regeneration time.

 b. 

Metered

 models alternate the Time of Day and Gallons left until the next regeneration. The meter will 

                 count down to zero (0000) and then regenerate at the scheduled time set.

2. 

Battery Back-Up

 (Uses a standard 9-volt alkaline battery.)

  

 

 

Features of Battery Back-Up:

 

 

• During power failures, the battery will maintain the time of day as long as the battery has power.

                            The display is turned off to conserve battery power during this time. To confirm that the battery 
                            is working, press either button and the display will turn on for five (5) seconds.

 

 

• If power failure occurs while system is regenerating, the will motor to a shut off position to pre

                            vent constant flow to drain. Depending upon system pressure and other factors, it is possible to 
                            observe a reduced flow to drain during this step. After power is restored, the valve will return 
                            and finish the cycle where it left off prior to the power interruption.
   
 

 

• When used without battery back-up, during a power failure, the unit stops at its current point in 

                            the regeneration position and then restarts at that point when the power is restored. The time 
                            will be offset by the increment of time the unit was

  

without power, so it is necessary to reset the 

                            time of day on the unit. No other system will be affected.

    

Starting Extra Regeneration Cycle

1. To Start 

Delayed Extra Cycle

     Example 

 

1

  ]

 

If Gallons Remaining Until Next Regeneration does not read ‘0000’, press and hold the 

Set/

                          Change 

button for 3 seconds until the display reads ‘0000’ on metered models.

 

Regeneration cycle will initiate at the next designated regeneration time.

2. To start 

Immediate Extra Cycle 

First complete above step. 

 

With Days Remaining Until Next Regeneration at ‘0000’,

 

Press and hold the 

Set/Change

 button.

 

After 3 seconds, the regeneration cycle will begin.

3. To 

Fast Cycle 

thru regeneration 

First complete above 2 steps.

 

Note

:

 Press and hold the 

Set/Change

 button for 3 seconds to advance to the next cycle step.

 

Fast Cycle is not necessary unless desired to manually step through each cycle step.

 

(Repeat until valve returns to the home display)

             
       
 

Softeners

                                                 Default (Min)

Step 1

Backwash

10

Step 2

Brine & Rinse

60

Step 3

Rapid Rinse

10

Step 4

Brine Refill 

15 lbs/ cu ft

  

Programming the Control Valve

Содержание HD33-3

Страница 1: ...High Capacity Softener Manual Installation Operation Manual...

Страница 2: ...Page 19 Bypass Assembly ISO III Page 21 Service Instructions Page 22 Troubleshooting Page 24 Error Codes Page 26 Warranty Information Page 28 FCC Compliance Statement http www chandlersystemsinc com f...

Страница 3: ...ials It is recom mended that Teflon tape be used to seal plastic Noryl threaded fittings Softener Specifications General Specifications General Specifications HD33 3 HD51 3 HD68 3 Grains Capacity Rege...

Страница 4: ...ft water The surfaces of these beads are covered with sodium ions As hard water enters the mineral tank and comes into contact with the resin an exchange of ions takes place as dissolved Calcium and M...

Страница 5: ...tallation Requirements A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the inlet to a water heater to prevent damage due to back up of hot water DO...

Страница 6: ...ded All plumbing lines not requiring soft water should be connected upstream of the softener The brine tank drain line is gravity flow and must discharge below the overflow fitting The brine overflow...

Страница 7: ...e pressure 3 Cut main line and install appropriate elbows and extensions Caution Raised arrows located on the sides of control valve body and bypass valve indicate proper direc tion of water flow Inst...

Страница 8: ...gs must be kept at a bare minimum Note Where the drain line is elevated above the control valve or exceeds 20 feet in length 3 4 I D drain line tubing should be used Brine Line and Overflow Connection...

Страница 9: ...leaking from bottom of bypass close and open bypass lever several times to seat o rings Exercise bypass valve 5 After air is evacuated from plumbing lines close bypass position of bypass lever is perp...

Страница 10: ...ain for 3 4 minutes 5 Advance control valve to BRINE TANK REFILL cycle 4 position and allow the control valve to automatical ly fill the brine tank Note Control valve will advance to service position...

Страница 11: ...2 Servicing the water softener 3 A water leak from the water softener is evident 4 Shock treating water well and piping with chlorine or other disinfectant Extra Regeneration If soft water demands ar...

Страница 12: ...the digit value press the Menu Enter button Once A M or P M is accepted the next menu item will flash 4 A To set Hardness an H will appear to enter Compensated Hardness in grains per gallon gpg Defaul...

Страница 13: ...return and finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position...

Страница 14: ...neration will begin at the scheduled time A setting of zero will cancel this feature Example Override every 7 days A 07 default setting or cancel setting A 00 Maximum is 29 3 Regeneration Cycle Step T...

Страница 15: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Страница 16: ...s in ORANGE with a set button can be changed For Filters Set Backwash Frequency This sets the amount of day between backwash cycles Change Time of Day Press SET to set time automatically based on devi...

Страница 17: ...p Option 2 Touch any graph to enlarge and see details Enlarged graphs are able to be zoomed in by pinching with two fingers Enlarged graph shown below Regenerate Unit at Next Regen Time button This wi...

Страница 18: ...heel 20001X007 1 5 Main Gear 21001X120 1 6 Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Legacy View Motor Assy 20016X006 1 10 Lower Back Base for Cover...

Страница 19: ...19 Valve Body Assy Softener Version 2 9 1 3 13 14 12 16 17 18 19 10 11 4 5 6 8 15 20 7 6A...

Страница 20: ...4 GPM 20251X268 1 6 DLFC Assy 20017X100 1 7 90 Degree Hose Barb Elbow 20017X266 1 8 Drain Retainer 20017X214 1 9 Brine Valve 20561X225 1 10 DLFC Assembly 20001X228 1 11 DLFC Ferrule 3 8 20251X305 1 12...

Страница 21: ...ll units 20017X284 3 1 Female Straight Slip Set optional 20017X288 4 1 NPT Straight Set optional 20017X289 5 3 4 NPT Straight Set optional 20017X307 6 3 4 Female Straight Slip Set optional 20017X290 7...

Страница 22: ...cover C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer...

Страница 23: ...move meter from valve body and clean or replace as necessary 5 Reinstall meter nut and cable G To Replace Brine Valve 1 Follow Piston Replacement instructions After the piston is removed pull the brin...

Страница 24: ...all times Clean it yearly Salt may be bridged If using a salt grid plate ensure refill water is over it Resin fouling Call dealer Find out how to con firm it Clean the resin and prevent future foulin...

Страница 25: ...oper control valve program ming Check and reset programming Plugged restrict drain line Clean drain line and or flow control button Injector and or screen is plugged Clean or replace injector and scre...

Страница 26: ...oder connection If the encoder is plugged in and snapped into place skip to step 2 below If encoder is disconnected reconnect it and cycle power to clear the error 2 Disconnect powerhead from valve bo...

Страница 27: ...e following factors The electrical outlet is not powered or is switched off The power cable has come unplugged from the circuit board The power supply has come unplugged from your electrical outlet Th...

Страница 28: ...ty does not cover labor costs shipping charges service charges delivery expenses property damage administrative fees or any costs incurred by the purchaser in removing or reinstalling the water treatm...

Отзывы: