50
|
53
Display Messages
Display
Display
Description
Description
PSI MODE
This displays when the pressure governor is in pressure mode.
RPM MODE
This displays when the pressure governor is in speed mode.
IDLE
This displays when the pressure governor is in idle mode.
HIGH
IDLE
This displays when the pressure governor is in high-idle mode.
NO J1939
ENGINE COMM
This displays when the J1939 network cannot establish communication over the engine.
NO J1939
ENGINE CONT
This displays when the J1936 network cannot establish control over the engine.
CHECK
ENGINE
This displays when a check engine code is received from the engine over the J1939 network.
STOP
ENGINE
This displays when a stop engine code is received from the engine over the J1939 network.
BATTERY
WARNING
This displays when the battery voltage is within the warning range.
BATTERY
CRITICAL
This displays when the battery voltage is within the critical range.
ENGINE
TEMP
This displays when the engine temperature is within the warning or critical range.
ENGINE
OIL
This displays when the engine oil pressure is within the warning or critical range.
TRANSMISSION
TEMP
This displays when the transmission temperature is within the warning or critical range.
CHECK
TRANSMISSION
This displays when a transmission error message sent over J1939 network.
NO MODE
SELECTED
This displays when you press the increment (+) or decrement (–) buttons, or turn the rotary knob before you select speed or pressure mode.
THROTTLE
NOT READY
This displays when you press the RPM button to enter speed mode and the throttle ready interlock input is inactive.