Waterous K Series Скачать руководство пользователя страница 3

F-1031, Section 2206 

Page 2 of 4 

 

 

CAUTION

 

Oil temperature hazard.

 

May cause premature seal wear and

damage.

 

Oil temperature should not exceed 250° for an extended period 
of time in order to prevent seal wear and damage. 

CAUTION

 

If oil level is low, locate the source of the leak and repair. If the 
oil  level  is  high,  loosen  the  drain  plug  until  the  oil  drops  to  the 
proper  level.  If  excessive  water  drains  out,  change  the  oil  and 
determine the source of the water leakage and repair. 

 

 

 

 

 

 

IL2155

 

Operating Instructions for K, T, TK & TA Series Transmissions

 

 

Since the K, T, TK and TA gear cases are designed to be driven by a PTO, 
power divider, or directly by the engine crankshaft, refer to the instruction 

manual supplied with the unit or to the apparatus manufacturer's manual for 
specific information. 

 

 

Lubrication

 

Maintenance

 

An oil splash system, within the gear case, lubricates the gears and other 
moving parts. Check oil level monthly by removing the square head pipe plug 
on side of gear case marked OIL LEVEL. The oil should be level with the bot- 
tom of the hole. 

 
 

 

 

To add  oil, remove filler plug or breather at top  of gear case, and  pour oil 
through  opening until oil comes  out the oil  level hole.  DO NOT OVERFILL. 
Use a SAE 80W-90 gear oil. 

Drain gear case by removing magnetic drain plug from bottom, and refill with 
new  lubricant  annually  or  after  each  100  hours  of  operation,  whichever 
comes  first.  (Under  severe  service  conditions,  where  pump  has  been 
used continuously at high output, change oil more frequently.) The  capacity 
is approximately one quart. Be sure to clean drain plug and breather. 

 

Figure 1. K Series Transmission 

Figure 2. T Series Transmission

 

(Vertical Mounting Position) 

(Vertical Mounting Position)

 

 

           

IL1529

 

Figure 3. TK Series Power Take-Off

 

(Vertical Mounting Position)

 

 
 
 
 
 
 
 
 
 
 

 

IL3885 

Figure 4. TA Series Transmission

 

(Vertical Mounting Position)

 

 

NOTE: Location of oil level plug, drain plug and breather will vary depending on the transmission mounting position. See the Service Parts List drawing 
for further details.

 

NOTICE 

NOTICE 

Отзывы: