Waterous CX Series Скачать руководство пользователя страница 6

Page 5 of 7

F−1031, Section 4209

Rev: 01/03/07

Packing  − Braided Flexible Graphite (BFG)

Waterous uses a braided graphite fiber, with reinforced flexible graphite yarns
and high purity graphite filament yarns that appear on the corners as well as
throughout the body of the packing. The graphite reinforcement allows the
flexible graphite yarns to provide greater tensile strength.

This type of packing reduces the frictional heat created between the shaft and
the I.D. of the packing. By dissipating the heat through the cross section of the
packing, the heat is transferred to the packing gland and the seal housing.

 WARNING

!

Packing Gland and Pump Body Temperature Hazard. May result in
serious burns.

Heat is dissipated through the cross−section of the packing, transferring
the heat to the packing gland and pump body.

Packing Removal

 WARNING

!

Truck movement hazard.
May cause serious personal injury.

Stop engine, set the parking brake and chock the wheels before going
under truck to remove packing.

1.

Remove the unbalanced nuts, flat washers and packing gland halves
from one end of the pump.

2.

Engage the pump per appropriate operating instructions. Operate the
pump gradually increasing the discharge pressure until the packing is
forced out of the seal housing. Pressure in excess of 300 psi (20.7 bar)
may be required.

CAUTION

Pump overheating hazard. 
May cause damage to the pump.

Circulate enough water through the pump to prevent overheating. Do not
pressurize the pump over 600 psi (41.4 bar).

3.

If all the packing is not forced out, it may be necessary to remove the re-
maining packing by hand, using a pick or similar device. Waterous has a
packing removal tool (P/N 5782) available for this purpose, see Figure 1.

4.

Replace packing per instructions below, repeating the procedure for the
opposite end of the pump.

Figure 2. Packing Removal Tool

IL1931

Packing Installation

1.

Before installing the new packing, be sure that all of the old packing is
removed from the seal housing.

2.

Be sure that the seal housing and the shaft are clean and free of any
packing residue.

3.

Lightly lubricate the packing ring I.D. and O.D. with mineral oil, automo-
tive grease or engine oil for installation purposes.

4.

Make sure packing is clean.

5.

Carefully install one ring of packing. With the aid of packing glands, push
the packing into the seal housing as far as possible. Repeat this opera-
tion with each ring, staggering the joints at least 90

_

 apart. Install the

packing rings until the top of the last ring is about 1/4 inch from the end
of the seal housing (at least 1/8 inch is required for the packing gland
nose entrance into the stuffing box), see Figure 3.

Содержание CX Series

Страница 1: ...tructions subject to change without notice Table of Contents Introduction 1 General Overhaul Information 1 Tools and Equipment 1 Preliminary Testing 1 Cleaning 1 Pump Bodies and Impellers 1 Bearings G...

Страница 2: ...ic pump troubles Excessive speed for instance indicates that impellers and or wear rings are probably worn Cleaning The continued satisfactory operation of a pump depends to a great extent upon the cl...

Страница 3: ...e CX provides easy access to water supply when drafting and in hydrant operation In addition front mounted pumps allow easy maintenance and repair Disassembly A CX Series pump may be disassembled in s...

Страница 4: ...r rings Examine lock nut and key for corrosion and other damage and replace if condition is doubtful Installing Undersize Wear Rings If inspection shows that the wear ring clearances are excessive or...

Страница 5: ...the end of the impeller shaft with the finish lapped face of the ring facing up the opposite side of a new seal ring has a mark on it Slide it along the shaft and push it into and seat it in the bore...

Страница 6: ...acking is forced out of the seal housing Pressure in excess of 300 psi 20 7 bar may be required CAUTION Pump overheating hazard May cause damage to the pump Circulate enough water through the pump to...

Страница 7: ...eakage rate of 10 to 120 drops per minute when operating at a discharge pressure of 150 psi 10 3 bar Leakage through the braided flexible graphite BFG packing may be at zero or diminish to zero leakag...

Страница 8: ...Hg 334 atmospheres in five 5 minutes listen for air leaks around the packing gland gaskets valves etc 3 Replace gaskets re adjust packing repack or otherwise repair source of trouble 4 Repeat test Te...

Отзывы: