Troubleshooting 

Malfunction 

Cause  

Remedy 

Cannot regulate temperature  Dirt in check valves 

 

Water supply reversed 

 

Valve installed upside down 

Remove and clean check valves 

 

Reverse hot and cold supply lines 

 

Reverse valve 

Hot and cold water do not mix  Lack of water pressure at  one 

of the inlets 

 

Blocked shower head 

Correct water pressure at source 

 

Remove shower head and clean debris.  

If necessary, soak in a 50/50 mix of 

white vinegar/ water or a de-scaling 

agent until all dirt is dissolved. 

Water not hot enough /   

Water too hot 

Debris in check valves 

 

 

Valve not properly calibrated 

 

Water heater setting incorrect 

Remove and clean check valves 

 

Calibrate valve following instructions on 

previous page 

 

Adjust water heater temperature setting 

Temperature selected on 

handle is different than actual 

water temperature 

Debris in check valves 

 

Valve not properly calibrated 

 

 

Uneven hot & cold water 

pressure 

Remove and clean check valves 

 

Calibrate valve following instructions on 

previous page 

 

Check and adjust water pressure for 

both hot & cold supply lines 

Handle does not turn 

Mineral build up 

Remove and clean cartridge following 

instructions above 

Low water pressure 

Low water pressure 

 

 

Debris in cartridge 

 

 

Debris in check valves 

 

Blocked shower head 

Check and adjust water pressure at 

source 

 

Remove and clean cartridge following 

instructions above 

 

Remove and clean check valves 

 

Remove shower head and clean debris.  

If necessary, soak in a 50/50 mix of 

white vinegar/ water or a de-scaling 

agent until all dirt is dissolved. 

Leaking shower head 

Fault cartridge in wall stop/ 

volume control 

Repair or replace cartridge in wall stop/ 

volume control 

Valve body too deep into wall  The measured rough in or 

finished wall surface is incorrect 

Install the proper extension kit: 

SS-EXT50 (need to specify finish) 

Содержание SS-THVD2

Страница 1: ...sure is 2 PSI to 72 PSI o When pressure is higher than 72 PSI a pressure reducer fitted before the valve is required o Temperature range is 50 F to 180 F o Recommended setting is 29 PSI and 149ºF Note USE TEFLON TAPE OR PIPE SEALANT FOR THREADED CONNECTIONS DO NOT USE PLUMBER S PUTTY ON ANY OF THE BRASS COMPONENTS This will cause the finish to tarnish and void the warranty A non corrosive Alkoxy S...

Страница 2: ... of the valve HOT marked with RED paint and cold supply to the right inlet COLD marked with BLUE paint 4 Use the plastic mud guard template part of the package to position the valve on the wall This is done by checking the label on the outer template for the minimum maximum settings which is 1 to 2 1 8 from the center of the valve inlets to the finished wall 5 Connect the outlet pipe s Refer to Di...

Страница 3: ... 6 has a larger opening than the Volume Control Dome 7 b Secure the Thermostatic Face Plate 1 onto the valve by sliding over the Temperature Control Dome 6 and Volume Control Dome 7 c Screw Dome Sleeve 13 onto Temperature Control Dome 6 and Volume Control Dome 7 d Lock the Thermostatic Face Plate 1 securely against the wall using the Thermostatic Face Plate Lock Ring 2 e Ensure Temperature Stop ri...

Страница 4: ...ermostatic valve has screens to prevent dirt and unwanted particles from damaging the valve Clogged screens can cause reduced flow and inefficient temperature mixture by the valve You can easily clean the screens by following the instructions below 1 Unscrew the two screws on the cover faceplate and remove the plate 2 Shut off the water inlets by tightening the two screws at the two check stop val...

Страница 5: ...should be included Description Qty 1 Face plate 1 2 Lock Ring 2 4 Temperature control handle post 1 5 Volume control handle post 1 6 Temperature control dome 1 Representative Trim Parts Checklist 7 Volume control dome 1 9 Volume Control handle 1 10 Temperature Control handle 1 11 Temperature control set screw for some models 1 12 set screw for some models 2 13 Dome sleeve raw brass 2 Representativ...

Страница 6: ...setting Temperature selected on handle is different than actual water temperature Debris in check valves Valve not properly calibrated Uneven hot cold water pressure Remove and clean check valves Calibrate valve following instructions on previous page Check and adjust water pressure for both hot cold supply lines Handle does not turn Mineral build up Remove and clean cartridge following instructio...

Страница 7: ...Thermostatic Shower with Built in Volume Control Diverter Thermostatic Shower Trim w Built in Volume Control Diverter P a g e 7 SS THVD2 SS THVD3 Rev 2 2014 ...

Страница 8: ......

Отзывы: