Warranty Information

RM1500-2 and RM1600-2

 warranty for Australia and New 

Zealand

The 

RM1500-2  and  RM1600-2

  valve  is  guaranteed  for  a  period  of  2  years  from  the  date  of  original 

purchase  to  be  free  of  material  or  manufacturing  defects.  Should  any  part  fail  as  a  result  of  such 

defects  within  this  period,  the 

RM1500-2  and  RM1600-2

  valve  will  be  repaired  or  replaced

  by  the 

manufacturer,

 free of charge. The 

RM1500-2 and RM1600-2

 valve also has a LIMITED LIFETIME WARRANTY 

on  all  brass  components,  any  brass  component  will  be  replaced  free  of charge  if  it  fails  in  normal use during 

its life.

This warranty applies in all states and territories in Australia and New Zealand. The warranty period commences 

on the day of the original purchase of the 

RM1500-2 and RM1600-2

 valve. Evidence of this purchase must be 

provided when claiming repairs or replacement, it is recommended you retain all receipts.

Both warranties are subject to conditions by the original purchaser with all conditions set out in the installation 

and operating instructions. Failure to comply with these instructions, damage or breakdown caused by fair wear 

and  tear,  negligence,  misuse,  incorrect  installation,  chemical  or  additives  in  the  water,  corrosive  or  abrasive 

water, inadequate conditions, attempting repairs or accidents, are not covered by this warranty.

Our  goods  come  with  guarantees  that  cannot  be  excluded  under  the  Australian  Consumer  Law.  If  you  are  a 

consumer as defined by the Australian Consumer Law, you are entitled to a replacement or refund for a major 

failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have 

the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a 

major failure. The 

above

 conditions form part of the instructions and do not over-ride your statutory rights. 

37 Export Street

Lytton  Qld  4178

+61 7 3893 5000

Fax

    

1

800 807 604

 

Email

    

[email protected]

 

globe

    

www.reefe.com.au

Содержание Reefe rainpro RM1500-2

Страница 1: ...1 Installation and Operating Instructions RM1500 2 and RM1600 2 RAIN TO MAINS CHANGEOVER VALVES ...

Страница 2: ...tive when rainwater is being drawn from the water tank it does not operate when the RM1500 2 and RM1600 2 Valve has switched to mains position The pump controller starts and stops the pump when it detects a demand for example flushing a toilet or using a washing machine The operating mechanism of the RM1500 2 and RM1600 2 Valves are a unique patent design it works by hydraulic water pressure creat...

Страница 3: ...Flow Rate L min Pressure drop verssus flow rate between the mains water inlet side and the outlet of the device Pressure drop verssus flow rate between the rainwater inlet side and the outlet of the device 40 35 30 25 20 15 10 5 Pressure drop kPa 0 10 15 20 25 Pressure drop vs flow rate Pump inlet side 35 40 50 45 30 Flow Rate L min ...

Страница 4: ...ROL To House Mains Water In Fig 2 Rainwater Tank 1 Pipe Submersible Pump with built in controller Mains Water In Fig 3 To House Bracket Fig 4 WARNING See also IMPORTANT INSTALLATION WARRANTY CONDITIONS on page 5 WARNING See also IMPORTANT INSTALLATION WARRANTY CONDITIONS on page 5 RM1500 2 or RM1600 2 valve RM1500 2 or RM1600 2 valve ...

Страница 5: ...in buildings is 500 KPa Ensure proper protection against freezing weather Complies to AS NZS 3500 1 when installed by a licenced plumber IMPORTANT INSTALLATION WARRANTY CONDITIONS EXTERNAL PUMPS 1 The mains supply must not exceed 500kPa refer AS NZS 3500 1 2 The pump must have flooded suction gravity feed of tank water with an inlet pipe not less than the size of the pump inlet typically 25mm 3 Th...

Страница 6: ...aterial 1 RM1500 2 RM1600 2 Body 1 DZR Brass 2 End Cap 1 DZR Brass 3 DN25 Nut 2 Brass 4 Brass Tail 1 DZR Brass 5 1 8 BSP Plug 1 Stainless Steel 6 Dual Check Valve 1 N A 7 Additional Outlet Port RM1500 2 only 1 N A RM1600 2 148 0 210 0 3 1 5 4 2 6 7 RM1500 2 ...

Страница 7: ...ng pump Clean Y Strainer No water is delivered from mains No water from mains Debris in valve Check isolation valve on water meter Open bleed plug Pump continually runs Leak in the plumbing system E g Toilet or tap leaking Faulty pump Repair Leak Contact pump manufacturer Maintenance The RM1500 2 or RM1600 2 Valve does not require any regular maintenance however there are things you can do to ensu...

Страница 8: ...eipts Both warranties are subject to conditions by the original purchaser with all conditions set out in the installation and operating instructions Failure to comply with these instructions damage or breakdown caused by fair wear and tear negligence misuse incorrect installation chemical or additives in the water corrosive or abrasive water inadequate conditions attempting repairs or accidents ar...