Watermaid WM10LED Скачать руководство пользователя страница 12

11

For 

On settings

, slide the pins away from the centre of the timeclock. 

For 

Off settings

, slide the pins towards the centre of the timeclock.

3) Position the small white switch to the clock setting.

N.B. If the timeclock on the WATERMAID is different to the one pictured and has just 

two settings, only the "I" and "clock" settings will be applicable.

7. THE CELL

 

When replacing the Cell, only use replacement Cells which have a label that clearly states that it 

is  a  replacement  Cell  for  the  chlorine  generating  device  WATERMAID  electrolytic  chlorinator 

model WM10LED, Registration 28114, Pest Control Products Act.

(i) CHLORINE PRODUCTION

The  WATERMAID  QT300  and  EZ300  Cells  are  capable  of  chlorinating  pools  up  to  150,000  litres 

(approx.  40,000  gal).  The  WATERMAID  chlorinator  should  produce  a  chlorine  level  in  a  pool 

between 1 and 3 ppm, and in a spa between 3 and 5 ppm.  

Chlorine production

 can be tested 

by  taking  a  sample  of  water  directly  from  the  outlet  flow.  This  reading  should  be 

greater  than 

elsewhere in the pool by approximately 0.5 ppm

.

If the WATERMAID shows no green lights, then one or more of the following may be the cause:

* the calcium level may be excessive (i.e. above 200ppm) in which case the Cell will need to be 

cleaned manually [refer to section 7(iii)] and the calcium level remedied.

* the Cell may need replacing.

(ii) SCALE FORMATION

If the pool or spa surface is fibreglass, fibreglassed concrete, painted concrete, vinyl-lined, epoxy 

coated  or  some  similar  inert  surface,  then  scale  can  originate  only  from  the  water  supply  or 

chemicals which have been added to the water and is therefore usually insignificant. 

If the pool 

or spa surface is marblesheen, pebbled, quartzon or tiled, then scale can originate from 

either the pool/spa water, chemicals added to the water or minerals that leach out of 

the walls.

Scale  is  usually  calcium  carbonate,  but  can  also  include  traces  of  silicon,  magnesium,  copper, 

iron, fats, oils and lotions.  As a guide, the calcium level of sea water is about 1700 ppm, some 

bore waters 400 ppm and city water supplies can range from 60 ppm to 200 ppm. 

 It is best to 

keep the calcium level in the water not more than 120 ppm.  A calcium level above 200 

ppm is considered excessive.

The  addition  of  chemicals  containing  calcium  is  not  recommended  with  WATERMAID  WM10 

chlorinators.  Please note: Powdered chlorine contains approximately 40% calcium. Adding pool 

acid  to  a  marblesheen,  pebbled,  quartzon  or  tiled  pool  will  cause  calcium  salts  to  be  released 

from the pool or spa surface.

Watermaid recommends the addition of up to 25Kg per year of Magnesium (Chloride or 

Sulphate) to the water.

If scale is allowed to engulf the centre cathode and outer mesh electrode, any or all of 

the following may result:

* Restricted water flow

* Interference to the electrical current

* Nil chlorine production

* Cell damage which may be beyond repair, voiding warranty.

(iii) MANUALLY CLEANING THE CELL

1.

 Turn OFF the power to the chlorinator and pump. There is no need to disconnect the Cell from 

the Power Supply when cleaning. 

2a)  For  QT  SERIES  Cells,

  unscrew  the  white  barrel  union  at  the  top  anticlockwise  and  the 

10

5. AUTO CELL CLEANING

Unique  Auto  Cell  Cleaning  circuitry  is  contained  within  the  WATERMAID  Power  Supply  (patent 

pending) and is programmed to:

1.

 Start producing chlorine for about 5 minutes once water is flowing through the Cell.

2.

 Begin its Auto Cell Clean phase for approximately 10 minutes, indicated by a 

blue 

light.

3. 

Revert back to chlorine production mode. The 

red

 light may light up for a few seconds while 

the unit checks the water flow and Cell connection.

4.

 Resume normal chlorine production until it cycles to Auto Cell Clean again.

As each pool and spa environment is different, the amount of build-up that is generated will differ 

from  one  environment  to  another.  For  example,  pools  or  spas  using  sea  water  will  experience 

higher levels of calcium in the water and so more build-up.

For  best  results,  it  is

 

recommended

 

that  the  WATERMAID  chlorinator  be  used  in 

conjunction  with  a  1HP  (or  greater)  pump  AND  the  addition  of  up  to  25Kg/Year  of 

Magnesium  [Magnesium  Sulphate

 

("Epsom  Salts")  or  Magnesium  Chloride]  to  the 

water.

It is important for the pool or spa owner to maintain water balance 

(refer to section 11). 

If there is an excessive amount of calcium (i.e. levels above 200 ppm), it may be necessary to 

clean the Cell manually [refer to section 7(iii)].  

The  use  of  chemicals  containing  calcium

 

are  NOT  recommended  for  use  with 

WATERMAID WM10 units. 

These include:

X Calcium chloride or "calcium hardness"

X Calcium hypochlorite or "powdered chlorine"

6. THE TIMECLOCK

"clock"  setting

  (in  the  middle)  -  the  chlorinator  will  operate  according  to  the  timeclock's 

programmed settings.

"O" setting

 - the timeclock is on standby.

1) The current time can be set by turning the clock face so that the arrowhead is aligned with the 

time on the clockface.

2)  The  times  for  the  chlorinator  and  pump  to  switch  on  and  off  (refer  to  section  9  "Running 

Times") can be set by aligning the pins as follows:

It is recommended that a timeclock be used to 

control  the  pump,  filter  and  WATERMAID 

chlorinator, and this may be internal or external 

to  the  WATERMAID.  Internal  timeclocks  may 

vary depending on availability.

HOW TO SET THE ANALOGUE TIMECLOCK 

ON THE WATERMAID

The first step is to turn OFF the power to both 

the WATERMAID Power Supply and pump.  This 

is  so  both  devices  do  not  start  and  stop 

erratically  whilst  the  timeclock  is  being 

adjusted.

THE 3 SETTINGS ON THE SWITCH:

"I"  setting

  -  chlorinator  will  be  ON 

permanently.

 

"I" Setting

"Clock" 

Setting

"O" Setting

Arrowhead

*One revolution equals a 24-hour cycle.
*The time is in 24 hour time (e.g. 18=6pm).
*Each pin equates to a 15 minute interval.

Содержание WM10LED

Страница 1: ...170 Bernie St Kya Sand Ph 27 11 794 1770 U S A FLORIDA Watermaid USA Inc Suite 404 7361 International Pl Sarasota 34240 Ph 800 737 3390 or 1 941 907 8982 HAWAII Aloha Salt Pools Ph 1 808 262 7258 AUST...

Страница 2: ...T SAFETY INSTRUCTIONS WATERMAID ELECTROLYTIC CHLORINATOR MODEL WM10LED CHLORINE GENERATING DEVICE DOMESTIC FOR RESIDENTIAL POOLS SPAS REGISTRATION NUMBER 28114 PEST CONTROL PRODUCTS ACT When installin...

Страница 3: ...orizontal Installation Diagram 4 The Power Supply 5 Auto Cell Cleaning 6 The Timeclock 7 The Cell 8 Salt Level 9 Running Times 10 Chlorine Depletion 11 The Langlier Index 12 Algae 13 Electricity Costs...

Страница 4: ...o pass water through a filter to remove debris A standard sized pool pump with normal filter pressures will pump about 10 000 litres 2 642 gal an hour so an average 60 000 litre 15 850 gal pool then r...

Страница 5: ...een pebbled quartzon and tiled pools and spas stabilise naturally between pH 7 6 and 8 2 so the effects of chlorine are disadvantaged For these pools and spas it is recommended that pH buffer sodium b...

Страница 6: ...TERMAID hydrometer or reading from a pool shop and align this value with the column that represents the size of the pool e g an 80 000 litre pool with a salt reading of 4000 ppm would need 160 Kg appr...

Страница 7: ...LUME IN LITRES LOWER ppm 10 20 30 40 50 60 70 80 90 100 U S Measurements Coversion Formulae To convert from Litres to Gallons x 0 2642 To convert from Kilograms to Pounds x 2 205 A microscopic photo o...

Страница 8: ...function of pH and water temperature and will then find its own equilibrium The ideal water balance is Water temperature of 15oC 30oC 59oF 86oF Calcium level of 60 120 ppm Magnesium level of greater t...

Страница 9: ...ing bather hours should produce a chlorine reading of 3 5 ppm 10 CHLORINE DEPLETION There are two main causes of chlorine depletion a The recent use of an algacide Most algacides contain ammonium comp...

Страница 10: ...0 ppm is isotonic with body tissue and in the case of accidental immersion will cause less damage to lungs and other body organs than water without salt Water at the recommended 6000 ppm is near isoto...

Страница 11: ...r outlet Unscrew the cover of the black junction box located at the base of the WATERMAID Power Supply Unscrew the single screw holding the Cell Cable as well as the 3 brass screws holding the 3 wires...

Страница 12: ...d water flow Interference to the electrical current Nil chlorine production Cell damage which may be beyond repair voiding warranty iii MANUALLY CLEANING THE CELL 1 Turn OFF the power to the chlorinat...

Отзывы: