WARNING!

  

DO NOT OPERATE IF DAMAGED.

  Unplug and isolate water supply if abnormal 

conditions exist. Contact Waterlogic or authorized dealer for repair, service, and installation 

to avoid hazards.  

WARNING! 

CONNECT TO POTABLE WATER SUPPLY.

  This system is to be used for water only 

and is not intended for use where water is microbiologically unsafe or with water of unknown 

quality without adequate disinfection before or after the system. 

 

WARNING!  

TIP HAZARD.  

Dispenser could tip or fall causing serious injury.  Always install 

unit on a firm, flat, and level surface and secure unit to cabinet, wall, or floor if needed.  

Never place heavy items on top of unit and never climb, stand, or hang on unit or storage 

cabinet to prevent injury and damage. 

 

WARNING!

  

UNIT IS HEAVY.  TWO PERSON LIFT REQUIRED.  

Transport unit empty and 

always use material handling equipment or two people with proper lifting technique to 

reduce injury risk. 

 

 

       WARNING!

  

STORE AND TRANSPORT UNIT EMPTY. 

  

ALWAYS SANITIZE BEFORE USE. 

The unit must be 

completely drained 

before storing to avoid stagnation and reduce 

microbiological contamination (potential bacterial growth).  Always sanitize before use to 

eliminate any potential microbiological contaminates.

 

 

CAUTION!

  

INDOOR USE ONLY.   

Intended for Household Use.

  

Never expose to direct 

sunlight, heat sources, or ambient air temperature above 37°C (100°F) or below 2°C (35°F).  

Install indoors and keep unit away from excessive humidity.  Never expose to freezing 

temperatures.  Ensure there is adequate clearance around the unit to allow refrigeration 

system condenser to dissipate heat.  Warmer environments require more clearance around 

the unit.  Minimum clearance around all surfaces of the machine is 2-inches.  Installs where 

the ambient temperature exceeds 27°C (80°F), require a minimum of 4-inches clearance for 

proper heat dissipation and efficient operation.    

 

CAUTION!

  

USE A WATER PRESSURE REGULATOR. Waterlogic

 will not be responsible for 

injury or damage caused by excessive water pressure.  Input or feed pressure must be 40 psi 

to 60 psi.  Be aware of any potential pressure surges caused by building/municipal pumping 

stations.   

 

CAUTION!

  

USE UV STABILIZED SUPPLY LINES.  

Feed the unit with a potable ambient or cold 

water supply only.

  

Feed water over 37°C (100°F) can damage the treatment components.  

Water block devices and external leak detectors are strongly recommended. Locate the unit 

as close to the water supply and the electrical connections as possible.  Locate the unit as 

close to the water supply and the electrical connections as possible.  Immediately isolate or 

close water supply valve and contact service representative if leak is noticed. 

 

Contact Waterlogic for assistance or help finding an Authorized Service Representative. 

Содержание WLH2 Classe

Страница 1: ...operated installed or maintained The installation maintenance sanitizing and any repair must be performed by qualified persons trained by Waterlogic International or their approved distributors only D...

Страница 2: ...r Household Use Never expose to direct sunlight heat sources or ambient air temperature above 37 C 100 F or below 2 C 35 F Install indoors and keep unit away from excessive humidity Never expose to fr...

Страница 3: ...int of dispense This point of dispense purification keeps the dispense nozzle free from external contamination as well as purifying the water making the freshest water possible Ice Bath Drain Port The...

Страница 4: ...no harmful BPA plastics NSF ANSI 55 Class A Ultraviolet Microbiological Water Treatment System NSF ANSI 372 Drinking Water System Components Lead Content This Firewall System conforms to NSF ANSI 55...

Страница 5: ...et Point 5 C 41 F Sparkling Tank Capacity 1 Liter Ice Bath Capacity 21 Liters Recommended Service Pressure 43 60 psi 275 414 kPa Use Pressure Regulator Recommended CO2 Service Pressure 50 60 psi 345 4...

Страница 6: ...65 Width Depth Height w Wheels 401mm W x 590mm D x 607mm H 15 79 x 23 25 x 23 9 Weight dry 48 kg 106 pounds ELECTRICAL SPECIFICATIONS ELECTRICAL SUPPLY 120V 60Hz 15 Amp Service COMPONENT POWER approxi...

Страница 7: ...med to dispense a preset volume of water and can be reprogrammed if desired One quick push Initiates dispensing of the preset volume of water Will automatically shut off once preset volume is dispense...

Страница 8: ...ll be flashing With a container in the dispense ready to contain the water dispensed give a short press and release of the dispense button you wish to preset Water will begin to be dispensed Once the...

Страница 9: ...gic for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting installation a...

Отзывы: