Run On 

 

“Run On” or “Carry On” is present in all Waterlogic pressure fed units without outlet solenoids. 

 

“Run On” is defined as the amount of water that continues to dispense out of the faucet after 
releasing the dispense button.  Run On exists because the tanks pressurize as water is being 
dispensed.  Every Waterlogic tank has an outlet restrictor to ensure the tanks remain full of water 
and water is controlled as it is released to the faucet.  The inlet solenoid controls flow into the tanks.  
The tanks will “depressurize” once the dispense button is released the inlet solenoid closes.  A small 
amount of water will “Run On” through the faucet as the tank depressurizes to atmospheric 
conditions.  Typical “Run On” is 2‐3 seconds.  “Run On” can be reduced by installing a pressure 
limiting device.   

 

The amount of inlet or supply pressure directly impacts the amount of “Run On” as quantified 
below. 

 

WLCP Lab Testing of Rn On 7‐31‐2013 

Pressure 

Pressure 

Time 

Flow Rate 

Run On 

Static PSI 

Dynamic PSI 

4 Liters 

I/min 

Seconds 

68 

40 

61 

2.9508197 

50 

30 

72 

2.5 

2.5 

32 

20 

92 

1.956217 

Pressure measured at inlet line to unit.  Static with unit closed.  Dynamic with unit dispensing cold‐
water. 
No Filters were installed in unit. 

 

3.

 

Low Flow of Water – Rated Service Flow is 1.89 Liters (0.5 gallons) per Minute  

 

Possible Reason 

Solution 

Determine Flow of 
Water  

Rated Flow Rate is 1.89 Liters (0.5 gallons) per minute

.  Check flow 

rate by dispensing into a container to measure for one minute and 
measure the amount of water that was dispensed.   

Feed Lines too small 

Feed lines can restrict flow if run long distances from the supply.  It 
may be necessary to increase the supply line (e.g., use 3/8” feed line 
vs. ¼”. 

Elbows and turns in 
the feed line 

Minimize elbows and turns in the feed line. 

Filters 

Filters with high pressure drop due to fouling or just by design.  
Change filters more frequently or go to higher micron size filter for 
local water conditions. 

Restrictions 

Follow flow path to ensure there are no undiscovered restrictions due 
to debris or malfunctioning valves, including the supply valve at the 
source. 

Booster Pump 

Add a booster pump to the supply line if the feed is slower than 
needed. 

 