background image

 

WL350

 Manual 

                                                                   Page 13 – Revision 11‐21‐2018 

SERVICE REQUIREMENTS 

 

WARNING!

  

Read and understand the contents of this manual before attempting to service 

WL350 Water Treatment System. Failure to follow the instructions in this manual could 
result in death, serious personal injury, or severe property damage.  Only trained and 
qualified technicians should attempt to install, maintain, or service Waterlogic Equipment.

 

 

1.

 

Visually inspect all electrical and water connections for signs of wear or damage.  
 

DANGER!  

HIGH VOLTAGE ELECTRICAL HAZARD.  

Unplug before inspection and service. 

 

2.

 

Waterlogic

 recommends changing the UV Lamp every 6 months. 

 

WARNING!  

ULTRAVIOLET RADIATION.  

Protect your skin and eyes against ultraviolet rays.  

Never look directly at an operating UV light.  Disconnect before removing UV Lamp. 

 

CAUTION!  

UV LAMPS ARE HAZARDOUS.  

Lamps are considered Hazardous Waste and must 

be disposed of accordingly.   Refer to Product MSDS sheet for details. 

 

3.

 

Clean the Spiral Quartz Sleeve that surrounds the UV Lamp with a non‐abrasive cloth, descaling 
solution, or ultrasonic bath if needed when changing UV Lamps. 
 

CAUTION!

  

UV SYSTEM IS FRAGILE.  

Never handle the UV lamp or Quartz Sleeve with bare 

hands.  UV Lamp and quartz sleeve must be free of oils and contaminants to ensure proper 
operation.  Use a soft non‐abrasive cloth to clean.

 

 

4.

 

Sanitize the Cold Tank per instructions in the pre‐installation procedures. 

 

5.

 

Clean and sanitize external surfaces of the unit.  Use soap and water or chemicals that are 
compatible with ABS plastic and will not damage or degrade the product surfaces.  

 

6.

 

 Remove and clean the Faucet.  Replace as needed. 

 

WARNING!  

SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS. 

 Use of proper personal 

protective equipment such as rubber gloves and eye protection is required.   

 

 

Содержание WL350

Страница 1: ...ing UV Lamp CAUTION UV LAMPS ARE HAZARDOUS Lamps are considered Hazardous Waste and must be disposed of accordingly Refer to Product MSDS sheet for details 3 Clean the Spiral Quartz Sleeve that surrou...

Страница 2: ...is a small hole in the side of the tank outlet tube that allows air and water to pass into the vent chamber as it is heated Water in the vent chamber is suctioned back through the outlet tube vent ho...

Страница 3: ...WL350 Manual Page 15 Revision 11 21 2018 HEATER CIRCUIT HOT TANK WIRING...

Страница 4: ...n the rear of the hot tank As you look through the condenser coils on the rear of the unit you will see the hot tank located on the right hand side 5 From the front of the Water Treatment System reach...

Страница 5: ...top flap of the Protective Metal Box so it snaps back into its original position on the Hot Tank 8 Replace the Lower Front Panel 9 Plug in the Power Cord 10 Turn on the Red Compressor Heater Switch I...

Страница 6: ...Hot Tank is made from stainless steel Ensure descaling solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Materials Needed Personal Pr...

Страница 7: ...faction WARNING HOT WATER The WL350 Water Treatment System produces Hot Water up to 86 C 187 F Water above 52 C 125 F can cause severe burns or scalding Hot water should be dispensed carefully into in...

Страница 8: ...WL350 Manual Page 20 Revision 11 21 2018 FIREWALL OUTLET SOLENOID REVERSE FLOW ORIENTATION...

Страница 9: ...tor External Capacitor New LG CSB035 LJCM Compressor Repair Replacement Parts for are not interchangeable with older other compressors Older version of LG compressor is obsolete and no longer availabl...

Страница 10: ...ew under the decal at the rear of the unit Remove the red portion of the Cold Tank Temperature label to access the adjustment screw The factory set point is 41 F and is indicated by the dot on sheet m...

Страница 11: ...ny button wakes up the WL350 Water Treatment System and turns the heater circuit back on The hot tank will typically take less than 10 minutes to heat the water from ambient to the 85 C 185 F set poin...

Страница 12: ...istor Control is for a future Hot Tank design Do not change to Thermistor or it will disable the Hot Tank Unplug Power Cord and remove Top Cover to access Heater Control PCB Thermostat Heater Control...

Страница 13: ...0 Water Treatment Systems comes defaulted with Hot Cold water which can be changed to Ambient Cold settings DF1 settings default is to Hot Cold Unplug Power Cord and remove Top Cover to access Energy...

Страница 14: ...ctory Part No FT 0063 IL Assembly containing FT 0064 Filter Element One pre installed One required for NSF 42 NSF 53 Certification Replacement parts can be obtained from Waterlogic or an Authorized Wa...

Страница 15: ...WL350 Manual Page 27 Revision 11 21 2018 WL350 COUNTER TOP DRAWING AND PARTS LIST Yellow Consumables Green Recommended spare parts Wetted Parts...

Страница 16: ...ended Spare Parts 4 1 12 6900 Thermostat and Overload Metal Cover Recommend stocking 2 each for every 10 units purchased ST 8290 Yes 4 2 12 1360 Overload with Manual reset 105 C 221 F Recommend stocki...

Страница 17: ...12 8056 Silicon Button Key Mat Recommend stocking 2 each for every 10 units purchased PL 1153 Yes 13 12 8057 Button Label Recommend stocking 2 each for every 10 units purchased LP 7084 Yes 14 12 8150...

Страница 18: ...r PU 4064 L00 00 Yes 23 ST 0049 L00 00 Metal Cover Counter Top Only ST 0049 L00 00 Yes 24 12 8375 Transformer 1 6A 120 V for Firewall Counter Top Only EL 5147 Yes 25 12 3165 Upper Shelf Counter Top On...

Страница 19: ...n Label PL 1359 Yes 34 Purchase from John Guest JG 3 8 x 1 4 Reducing Fitting PI211208S PU 4137 No 35 NA Firewall Solenoid Valve Fixing Bracket Counter Top Only ST 8297 No 36 NA Filter Bracket Counter...

Страница 20: ...itor CO 0019 L00 00 Yes 41A 3 ST 0216 L00 00 Capacitor Bracket ST 0216 L00 00 Yes 41A 4 CO 0017 L00 00 PTC Relay CO 0017 L00 00 Yes 41A 5 CO 0018 L00 00 Overload Protector CO 0018 L00 00 Yes CO 9001 A...

Страница 21: ...Thermostat CT 2070 A Yes 45 1 LP 0326 Cold Thermostat Cover Label LP 0326 L00 00 Yes 46 10 4013 Power Socket EL 5016 Yes 47 10 3014 Fuse Holder and Fuse 120V 15A with One Wire EL 5053 Yes 47 1 10 3013...

Страница 22: ...WL350 Manual Page 34 Revision 11 21 2018 WL350 TOWER LAYOUT DRAWING AND PARTS LIST Yellow Consumables Green Recommended spare parts Wetted Parts...

Страница 23: ...rts 3 1 12 6900 Thermostat and Overload Metal Cover Recommend stocking 2 each for every 10 units purchased ST 0045 L00 00 Yes 3 2 12 1360 Overload with Manual Reset 105 C 221 F Recommend stocking 2 ea...

Страница 24: ...urchased EN 6126 L00 00 Yes 11 12 8056 Silicon Button Key Mat Recommend stocking 2 each for every 10 units purchased PL 1153 Yes 12 12 8057 Button Label Recommend stocking 2 each for every 10 units pu...

Страница 25: ...Tank Assembly No UV holder No sub tank Tower Only CT 2017 A No 21 Purchase from John Guest Union Tee John Guest P N P10208S PU 4011 No 22 12 5673 Silver Back Panel ST 8135 A No 23 19 1069 Cold Tank Th...

Страница 26: ...6A 120 V for Firewall Tower Only EL 5003 A Yes 31 ST 0059 L00 00 Electric Ballast Bracket NA No 32 12 8000 Silver Side Panel with Hole for Handle Tower Only ST 8157 Yes 33 12 8058 Side Panel Plastic H...

Страница 27: ...2 Front Bottom Panel Tower Only PL 1148 Yes 41 12 8053 Front Bottom Insert Panel Tower Only PL 1149 Yes 42 12 8005 Filter Bracket Tower Only ST 8138 Yes 43 20 1010 2 8 Filter Clip PU 4161 Yes 44 10 30...

Страница 28: ...L00 00 Yes 48A 2 CO 0019 L00 00 Compressor Capacitor CO 0019 L00 00 Yes 48A 3 ST 0216 L00 00 Capacitor Bracket ST 0216 L00 00 Yes 48A 4 CO 0017 L00 00 PTC Relay CO 0017 L00 00 Yes 48A 5 CO 0018 L00 0...

Страница 29: ...WL350 Manual Page 41 Revision 11 21 2018 WL350 COUNTER TOP WATER FLOW DIAGRAM...

Страница 30: ...WL350 Manual Page 42 Revision 11 21 2018 WL350 TOWER WATER FLOW DIAGRAM...

Страница 31: ...ual Page 43 Revision 11 21 2018 WL350 ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technicians should attempt liv...