WL100
Manual Page 62 Revision: 1‐14‐2019
6.
Allow descaling solution to remain in the Hot Tank for 15 minutes (length of time may vary
depending on water conditions).
7.
Place a pitcher, catch basin or other container under the faucet of the
WL100 Water Treatment
System
.
8.
Flush the Hot Tank until water runs clear.
9.
Once clear Water dispenses from the Faucet, the Hot Tank has been descaled. Always ensure
unit is performing to the customer’s satisfaction.
10.
Replace Filters.
WARNING!
HOT WATER. Unit produces Hot Water up to 87
o
C (189
o
F).
Water above 52
o
C
(125
o
F) can cause severe burns or scalding. Hot water should be dispensed carefully into
insulated container to avoid injury.
CAUTION
!
MUST
REPLACE HOT TANK EVERY 3‐5 YEARS DEPENDING ON USAGE
. The Hot
Tank and its controls must be replaced a minimum of every 3‐5 years depending on usage to
ensure efficient and dependable operation.
WARNING!
REINSTALL ALL PANELS AND COVERS.
Always reinstall all Panels, Protective
Covers, and Fasteners after servicing equipment. Failure to do so could result in severe
personal injury and will void the certifications and warranty of the equipment
.