WL100
Operating,
Installation,
and
Service
Manual
Page
22
Revision:
5
‐
20
‐
2016
Pre
‐
installation
and
sanitization
procedures
as
prescribed
in
this
manual
must
be
performed
before
installing
the
WL100
Water
Treatment
System
.
Always
install
indoors
and
place
the
Waterlogic
WL100
Water
Treatment
System
on
a
firm,
flat
and
stable
surface.
1.
Attach
the
water
supply
line
to
the
1/4”
feed
water
inlet
bulkhead
fitting
on
the
back
of
the
unit.
Waterlogic
requires
the
use
of
a
water
pressure
regulator.
Water
feed
pressure
must
be
between
40
‐
60
psi.
Turn
on
the
water
supply
and
check
for
leaks.
2.
Check
to
ensure
that
the
Red
Heater
and
Compressor
Switch
is
the
O=OFF
position.
NOTE:
Switches
have
internal
LED
that
illuminates
when
placed
in
I=ON
position
3.
Connect
the
power
cord
to
the
back
of
the
Waterlogic
WL100
Water
Treatment
System
and
to
a
120
Volt
supply.
4.
Fill
the
Cold
Tank.
Hold
a
container
under
the
dispensing
faucet,
press
and
hold
Cold
(Blue)
dispensing
button
until
a
continuous
flow
of
water
is
obtained.
Once
a
continuous
flow
is
obtained,
release
the
dispensing
button.
Cold
tank
is
now
full.
5.
Fill
the
Hot
Tank.
Hold
a
container
under
the
dispensing
faucet.
Press
both
of
the
Hot
(Red)
Dispensing
buttons
until
a
continuous
flow
of
water
is
obtained.
Once
a
continuous
flow
is
obtained,
the
Hot
Tank
is
full.
CAUTION!
NEVER
TURN
ON
HEATER
BEFORE
FILLING
HOT
TANK.
Red
Heater
and
Compressor
Switch
must
be
in
the
O=OFF
position
while
the
hot
tank
is
empty.
Damage
could
occur
within
one
minute
and
the
overload
(high
limit)
will
require
manual
reset
if
heater
is
turned
on
with
an
empty
hot
tank.
6.
Move
the
Waterlogic
WL100
Water
Treatment
System
into
its
final
operating
position.
Be
sure
that
a
minimum
of
2”
clearance
is
maintained
around
both
the
sides
and
the
back
of
the
unit.
This
is
important
to
allow
proper
airflow
and
heat
exchange
of
refrigeration
system.
7.
Level
unit
using
the
adjustable
feet
to
level
if
necessary.
Never
install
on
incline.
8.
Turn
the
Red
Heater
and
Compressor
Switch
on
I=ON
position
.
9.
When
the
unit
has
reached
its
Hot
Temp
Set
Point,
the
heater
will
cycle
off.
When
the
unit
has
reached
its
Cold
Temp
Set
Point
Temperature,
the
compressor
will
cycle
off.
10.
Once
the
unit
is
at
the
target
temperature(s),
sample
the
water
to
ensure
water
meets
expectations
and
additional
rinsing
or
adjustment
is
not
required.
11.
Check
the
WL100
Water
Treatment
System
for
any
leaks.
External
Leak
Protection
is
always
recommended.