background image

22

23

WL Max Technical Manual - Version 1 - May 2013

Technical Specifications 

and Warranties

SaFETY

Subject to the standard terms and conditions of sale (a copy of which has been 

provided to you), neither Waterlogic International Limited (“Waterlogic”), nor any 

affiliated companies shall be liable for any damage which could affect, directly or 

indirectly, any person or property.  

Please be aware that any warranties accompanying the sale of our products will 

be invalidated by any of the following:

• Incorrect installation

• Incorrect use of the WL Max

• Unsuitable electrical and water supply

• Major short-coming of maintenance

• Technical interventions or alterations of an unauthorized nature

• Adoption and use of unapproved spare parts

• Engagement of untrained personnel 

Waterlogic has a policy of constant and continual improvement and therefore 

reserves the right to change specifications without prior notice, other than in the 

case of significant changes.

Description

WL Max 1 Water Distribution WL Max 2 Water Distributions

Machine Size

W 321 mm, H 1413.5 mm, 

D 335 mm

W 321 mm, H 1413.5 mm, 

D 335 mm

Machine Weight 

34.5Kg

36Kg

Power Supply

220-240 Volt / 50Hz

220-240 Volt / 50Hz

Dispense Area Height

330mm

330mm

Fan    

N/A

N/A

Compressor     

230V/50Hz  (R134a) 

230V/50Hz  (R134a) 

UV Lamp 

13W

2 x 13W

Unit Total    

300W

313W

Refrigeration Gas R134a 

165g

165g

Cold Tank Capacity 

 Direct Chill

Direct Chill 

Water Connection 

1/4” Hose

1/4” Hose

Minimum Water Pressure 

Megapascal (Bar) 

0.26 (2.6) 

0.26 (2.6) 

Maximum Water Pressure 

Megapascal (Bar) 

0.32 (3.2)

0.32 (3.2)

Recommended Water 

Pressure Megapascal (Bar) 

0.3 (3.0)

0.3 (3.0)

Minimum Incoming Flow 

Rate (litres per minute) 

1.2 lpm

1.2 lpm

Cold Water Dispensing 

Capacity

65lph

65lph

Cold Water Temperature 

5 - 8°C 

5 - 8°C 

Содержание WL Max

Страница 1: ...WL Max Technical Manual Version 1 May 2013 WL Max Technical Manual...

Страница 2: ...ures PDI 11 Installation Procedures 12 Installation Kit 14 Operating Instructions 15 Maintenance and Servicing 16 Sanitizing 18 Fault Finding 20 Technical Specifications and Warranties 22 End of Life...

Страница 3: ...ne and pesticides It is important for the UV sterilization system to be supplied with clean water in order to achieve maximum efficiency There are many kinds of different filter combinations available...

Страница 4: ...all the mechanical and electrical parts 24V DC including the solenoid valves COMPRESSOR The compressor operates at 220 240V at 50Hz or 120V at 60Hz It uses 165g of R134a non Ozone depleting refrigera...

Страница 5: ...et Flow Diagram Double Faucet DRAIN VALVE FILTER IN Water COLD WATER OUT FILTER DRYER ICE BANK COMPRESSOR CONDENSER COLD SENSOR SOLENOID VALVE DRAIN VALVE FILTER IN Water COLD WATER OUT FILTER DRYER I...

Страница 6: ...top cover from the Firewall Housing and inspect the quartz spiral for damage If all is ok then re assemble 7 Connect to a potable drinking water supply via a 1 4 John Guest tube the sup ply must be li...

Страница 7: ...away from the top 8 Replace the cap on the top of the reservoir 9 Make the water connection using an installation kit Waterlogic recommends the use of a pressure reducing valve a shut off valve and a...

Страница 8: ...water 3 Adjustable Pressure Reducing Valve 4 Integral Isolator 5 Pressure Gauge Port 6 Waterblock 7 1 4 Pushfit Outlet The part number for the installation kit shown below is P KIT INSTALLATION Your...

Страница 9: ...directly into the inlet side of the filter and attach another length of pipe to the outlet side and direct this into a bucket large container or drain then allow 10 litres of water to pass through the...

Страница 10: ...itisation fluid leaves the faucet Whilst you are dispensing the cold water hold a peroxide test strip under the dispense area and test the flow of water to check that the sanitisation fluid is present...

Страница 11: ...sconnect power supply for one hour to allow the tank to defrost and then flush the cold water system Check the temperature settings are correct If the cold reservoir is not frozen then check the solen...

Страница 12: ...erlogic has a policy of constant and continual improvement and therefore reserves the right to change specifications without prior notice other than in the case of significant changes Description WL M...

Страница 13: ...r technology is manufactured into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory to show...

Страница 14: ...26 27 WL Max Technical Manual Version 1 May 2013 Electrical Wiring Diagram 230V DANGER HIGH VOLTAGES PRESENT ON THIS PCB CARE MUST BE TAKEN WHEN LIVE TESTING...

Страница 15: ...No Part Description 1 PU 4031 JG 1 4 PE Pipe 2 PU 4028 JG Bulkhead Connector Union 1 4 1 4 3 PU 4031 JG 1 4 PE Pipe 4 FT 0034 10 Inline CBC Filter 1 Micron 5 PU 4008 JG Equal Elbow Connector 1 4 6 St...

Страница 16: ...rt Description 1 PU 4031 JG 1 4 PE Pipe 2 PU 4028 JG Bulkhead Connector Union 1 4 1 4 3 PU 4031 JG 1 4 PE Pipe 4 FT 0034 10 Inline CBC Filter 1 Micron 5 PU 4008 JG Equal Elbow Connector 1 4 6 Stainles...

Страница 17: ...1 4 Elbow 13 Quartz Spiral 14 JG 1 4 Straight Connector 15 Firewall Housing 16 Solenoid Valve 24V DC 17 Back Cover 18 JG 1 4 Straight Connector 19 JG 1 4 Divider 20 Ballast 15W 220 V 21 Firewall displ...

Страница 18: ...0 Inline CBC Filter 31 JG 1 4 Bulkhead Connector 32 Filter Clip 33 JG 1 4 Elbow 34 JG 1 4 Straight Connector 35 Drain Hose 36 Reservoir Tank Lid 37 Pump 38 Reservoir 39 Thermostat 40 Drain Connection...

Страница 19: ...Beacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 4141 N 156th Street Omaha NE 68116 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA Ca...

Отзывы: