10.
Remove the Filter Cartridge from the filter head by turning the base in
a clockwise direction.
11.
Remove the Hot Drain Valve Cap at the back of the
CUBE
until all
water has been removed.
12.
Add Descaling Solution (minimum 2 ounces of descaling powder) to Empty Filter Body.
13.
Screw the Filter Body to the filter head in a counter‐clockwise motion,
it must be securely tightened.
14.
a.
Insert the Filter
Assembly back into
its cradle, aligning
the two male ports
with the female holes
in the cradle
b.
Push it firmly until
the Filter is securely
in place and is flush
with the cradle top
surface.
c.
Lock the filter by
closing the locking
lever until it ‘clicks’
into place.
15.
Turn on the water supply at the isolation point