background image

Waterlogic 4 Firewall User Manual- Issue 1, January 2011 

10

Waterlogic 4 Firewall User Manual- Issue 1, January 2011 

11

CLEANING, MAINTENANCE AND SERVICING 

Weekly Cleaning 

It is recommended that you clean your Waterlogic water dispenser at least once per week. 
Please follow the cleaning procedure below:

  Before  starting,  please  turn  off  the  power  at  the  wall  socket  and  remove  the 

power cord.

  Please put on clean rubber gloves before commencing with the cleaning procedure. 

  Remove and empty the drip tray assembly. 

  Clean  drip  tray  assembly  and  all  machine  surfaces  with  non-abrasive  vending 

machine cleaner/sanitizer. 

  Using an Anti Bacterial Wipe, thoroughly clean the water dispense buttons and 

water dispense areas.

  Reconnect mains power and check for correct operation. 

  If you should notice any damage or detect any leakage, turn off the water supply

and  disconnect  the  power  cord  from  the  wall  plug.  If  it  is  deemed  safe  then 
contact your authorised service agent. 

Your service agent will also be able to supply suitable cleaning/sanitising products for use  
on your water dispenser as recommended by Waterlogic International Ltd.

Maintenance and servicing

To ensure that your Waterlogic water dispenser is always working to its optimum level, we 
recommend that it is serviced by a trained technician every six months.
During  these  maintenance  service  visits,  the  filter(s)  and  UV  lamp  will  be  replaced.  The 
technician will also clean and sanitise the machine and ensure that it is operating correctly.
Models dispensing hot water will also be de-scaled as required (Hard water areas).
Please contact your authorised service agent to arrange your six monthly services.

TECHNICAL SPECIFICATIONS

DESCRIPTION

WL4 HCS WL4 HC

WL4 CS

WL4 CA

WL4 C 

Machine Size

417mm(W) x 439mm(D) x 470mm(H)

Base Cabinet Size

418mm(W) x 803.4mm(D) x 467.3mm(H)

Mini & BC Size

418mm(W) x 1238mm(D) x 470mm(H)

Machine Weight

35kg

27kg

34kg

26kg

26kg

Base Cabinet Weight

18kg

Power Supply

230 Volt / 50Hz

Heater

800W

800W

N/A

N/A

N/A

Fan

16W

16W

16W

16W

16W

Compressor

114W

114W

114W

114W

114W

PCB

6W

6W

6W

6W

6W

Pump

12W

N/A

12W

N/A

N/A

UV Lamp

11W

11W

11W

11W

11W

Others

27W

27W

27W

27W

18W

Unit Total

986W

974W

186W

174W

165W

Refrigeration Gas R134a

75g

75g

75g

75g

75g

Cold Tank Capacity

4.5 Litre

4.5 Litre

4.5 Litre

4.5 Litre

4.5 Litre

Hot Tank Capacity

1.2 Litre

1.2 Litre

N/A

N/A

N/A

CO2 Bottle (Max)

10kg

N/A

10kg

N/A

N/A

Water Connection

1/4” Hose 1/4” Hose 1/4” Hose 1/4” Hose 1/4” Hose

Minimum Water Pressure 

Megapascal (Bar)

0.15 (1.5) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5) 0.15 (1.5)

Maximum Water Pressure 

Megapascal (Bar)

0.35 (3.5) 0.35 (3.5) 0.35 (3.5) 0.35 (3.5) 0.35 (3.5)

Recommended Water Pressure

Megapascal (Bar)

0.30 (3.0) 0.30 (3.0) 0.30 (3.0) 0.30 (3.0) 0.30 (3.0)

Extra Hot Water Temperature

93°C

93°C

N/A

N/A

N/A

Hot Water Temperature

87°C

87°C

N/A

N/A

N/A

Cold Water Temperature

6°C

6°C

6°C

6°C

6°C

Sparkling Water Temperature

6°C

N/A

6°C

N/A

N/A

Your authorised service agent is:

Содержание 4 Firewall

Страница 1: ...User Manual...

Страница 2: ...pliance YOUR WATERLOGIC WATER DISPENSER The Waterlogic 4 Firewall The Waterlogic 4 Firewall is a state of the art mains fed drinking water dispenser With its advanced filtration system impurities such...

Страница 3: ...tton continuously until cup is full n Never try to fill more than one vessel at a time OPERATING INSTRUCTIONS HOT water Press the hot water and extra hot water buttons together for 3 seconds safety de...

Страница 4: ...ater Press the extra hot button for 3 seconds The symbols for hot and extra hot water in the display light up to indicate that the water is heating Once the icons disappear the water has reached the r...

Страница 5: ...chine out of sleep mode Extra hot water has been selected The Waterlogic 4 Firewall is heating up No water supply check the water supply is turned on if fault persists please call your authorised serv...

Страница 6: ...ter s and UV lamp will be replaced The technician will also clean and sanitise the machine and ensure that it is operating correctly Models dispensing hot water will also be de scaled as required Hard...

Страница 7: ...re parts Repair or servicing by untrained personnel Waterlogic has a policy of constant and continual improvement and therefore reserves the right to change specifications without prior notice other t...

Страница 8: ...and that the red power switch is turned on Check that the power cord is securely fitted to the socket at the rear of the machine All icons flashining and audible alarm An overheat fault has been dete...

Страница 9: ...For further information on Waterlogic and our products please contact your local distributor or visit www waterlogic com ENG0021 13 04 11...

Отзывы: