3) Cut 1-3/8˝ section out of tubing a minimum of 2˝ above the
existing cold water stop valve and removes any burrs.
4) Mark both sections 3/4˝ from the ends as a guide for inserting into
the new supply valve quick connect fittings.
5) Insert tubing into bottom & top of this valve to insertion line.
6) For Flexible hose installation from step 2.
7) Disconnect cold water line from existing 3/8˝ NPS stop valve
8) Apply 3-4 wraps of Teflon tape onto Male threads of the existing
3/8˝ NPS stop valve.
9) Connect the faucet female adapter to existing stop valve. Do not
over tighten.
10) Push tube end of Faucet female adapter into bottom of the new
supply valve to insertion line.
11) Apply 3-4 wraps of Teflon tape onto male threads of Faucet male
adapter.
12) Using the supply line flexible hose previously connecting the cold
water line connect the Faucet male adapter. Do not over tighten.
13) Push tube end of faucet male adapter into top of the new supply
valve to insertion line.
B
B:: LLo
occa
attiio
on
n d
deetta
aiills
s ffo
orr:: N
Neew
w S
Seep
pa
arra
attee D
Diissp
peen
nssiin
ng
g T
Ta
ap
p
1) This tap should be positioned with function, convenience, and
appearance in mind. An adequate flat area is required to allow
faucet base to rest securely. Most sinks have pre-drilled 1-3/8˝ or
1-1/2˝ diameter holes that may be used for this tap installation. If
these holes cannot be used or are in an inconvenient location, it
will be necessary to drill a new hole. A 1-1/4˝ hole is recommended.
a. Waterline has hole saws available for porcelain over cast iron
and for stainless or fiberglass type sinks.
b. The stainless hole saw has also worked effectively for hard
surface counter tops which use a carbide tip for drilling.
c. Do not use either of these saws for marble, granite or other
surfaces without consulting the manufacturer or dealer where
purchased.
d. Drilling may result in damage to your sink or countertop and
Waterline is not responsible for any such damage. Consult a
plumber, countertop manufacturer or sink manufacturer for
instructions.
NOTE:
You may wish to use the existing cold water sink faucet installation
section in lieu of a separate dispensing tap if this become a problem.
C
C:: M
Mo
ou
un
nttiin
ng
g tth
hee D
Diis
sp
peen
ns
siin
ng
g T
Ta
ap
p
Consult the dispensing tap instructions.
NOTE:
A 3/8˝ tube x 7/16˝
faucet adapter fitting is supplied with this system to make a quick
connection to this faucet and outlet of filter using the union fitting
connected to filter outlet 3/8˝ tubing.
NOTE:
Install the filter to thread
shank on faucet.
D: Connecting the water supply to Filter
IIN
NLLE
ET
T F
Fiittttiin
ng
g::
1) Determine the length of plastic tubing (3/8˝ tubing 5´ supplied with
system) needed to connect the inlet (left side) of the filter with the
supply stop valve.
a. Be sure to allow enough tubing to prevent kinking and cut the
tubing squarely and remove all burrs. Place a mark 3/4˝ from
end of tubing.
b. Wet tubing with water and insert into outlet (side fitting) of
supply valve 3/4˝until mark is flush with fitting.
c. Place a mark 3/4˝ from other end of tubing.
d. Insert tubing into fitting inlet of system to insertion mark.
O
OU
UT
TLLE
ET
T F
Fiittttiin
ng
g::
1) Insert union connector into faucet adapter fitting 3/4˝.
2) Determine the length of tubing (3/8˝ tubing supplied) with system
to make the connection from the outlet fitting of filter to 3/8˝
union connection which is also connected to the faucet adapter
fitting on bottom of dispensing tap.
A 3´ minimum length is
suggested to connect accessories to this line.
a. Place a mark 3/4˝ from end of tubing.
b. Wet tubing with water and insert into union connecter until
mark (3/4˝) is flush with this fitting.
3) Double check that the water supply is directed to the filter inlet
and the outlet is directed to the sink cold faucet line.
PLACING FILTER IN OPERATION
Turn on water supply valve and check for leaks.
1) Leave the cold water faucet at the sink turned off to allow system to
come up to pressure. Recheck for leaks after 3 minutes.
2) Turn on filter water dispensing faucet and allow water to run until
clear. Normally 2-3 minutes is adequate.
CONNECTING ADDITIONAL WATER USING
APPLIANCES TO THIS FILTERING SYSTEM
You can readily connect your refrigerator ice / water dispensing sys-
tem to this filter. Connect a 3/8˝ reducing tee in the line between the
filter and faucet (see instruction example)
1) If your refrigerator is equipped with a built-in filter already consult
your instruction manual for by-pass instructions.
There will be no need to use both and one does not want to leave in
the refrigerator filter without replacing it periodically so you will want
to bypass it at this time.
2) Multiple tees can be inserted to service other appliances and
locations. Consult the appliance instructions for inlet tube size!
a. Built-in coffee makers
b. Instant Hot taps/under counter chillers
c. Prep sink, other sink locations that you can conveniently run a
3/8˝ line to service the existing sink faucet
R
Reep
plla
acceem
meen
ntt C
Ca
arrttrriid
dg
gee P
Prro
og
grra
am
mss::
Waterline offers several
programs that are designed to insure your system is properly main-
tained.
R
RC
CR
RS
S::
Replacement Cartridge Reminder Service, You can enroll to
be notified every 11 months that it is time to change your cartridge. Go
to
www.waterlinetechnology.com
click on Cartridge Replacement
icon and then click “Register your product” icon to enroll.
A
AC
CD
DP
P::
Automatic Cartridge Delivery Program, Waterline will send
you a new replacement cartridge of your choice every 12 months.
i. Save 15% on your cartridge under this program
ii. Lock in the current list price for up to 3 years
iii.Automatically enrolled in our extended lifetime warranty (ELW)
iv. Go to
www.waterlinetechnology.com
click on Cartridge
Replacement icon and then select to enroll on line or download
the enrollment form.
Y
Yo
ou
u m
ma
ay
y a
allsso
o cca
allll o
ou
urr o
offffiiccee a
att
1-800-522-3949
tto
o een
nrro
ollll iin
n eeiitth
heerr p
prro
og
grra
am
m..
3