background image

Q: Can the Vectapure NX™ system be connected to an extra faucet? 

Yes.  Many installations will include an optional ¼” line to refrigerator icemakers or additional 
sink faucets.

  

See your dealer for

 

advice and parts

 

Q: What factors affect the quantity and the quality of the water produced? 

1.  Pressure: The greater the water system pressure, the greater the water quantity that will 

be produced.  60PSI is optimal, but system pressure  should never exceed 80PSI.  
Where water pressures are low (<40PSI), a booster pump on the raw water line can be 
added to increase production.   Your system is equipped  with a pressure regulating 
device that will, when installed, limit the raw water pressure delivered to the system to 
about 60PSI.  

2.  Temperature: Production increases with temperature, the optimal being 76F.  Never 

operate the system from the hot water line  or with water exceeding 85F, as this will 
damage the membrane. 

3.  Membrane type: Vectapure NX

TM

  system  uses  premium quality TFC (Thin Film 

Composite) membranes, specially chosen for household applications. 

4. 

TDS: The higher the Total Dissolved Solids in the raw water, the lower the output of 
product water.  

 

 

Q: How much water does the Vectapure NX™ system produce? 

RO4053HNX  systems use

 

membranes nominally rated for 75GPD;  RO405400NX

TM

  systems 

are rated for 400GPD.  Actual output will be dependent upon the factors explained above.  In 
optimal applications (with a booster pump) you may expect 60-70 gallons/320-400 gallons 
(400NX

TM

 systems) to be available over 24 hours. 

 

Q: Can the amount of water produced be increased?  

Filling a water pitcher for the refrigerator will allow more production overnight.   A larger holding 
tank (available from your dealer) will allow for more water to be on hand.  Booster pumps will 
also increase daily production. 

 

Q: What is the standard warranty with the Vectapure NX™ system? 

Every Vectapure NX™ system comes with a standard one-year limited warranty on all parts and 
repair labour.  A detailed warranty card is included with the unit.  

You may purchase and 

extended warranty if you wish -  see the enclosed Extended Warranty Program 
information sheet and enrolment form included in your package.  Call your dealer if you 
wish to have one sent to you

.  Normal filter cartridge replacement is excluded from your 

warranty. 

 

Q: What is the maintenance schedule for the Vectapure NX™ system? 

A good rule of thumb is to replace all pre-filters every three months.  This is critical to ensure 
that chlorine does not attack the membrane film.  The carbon post-filter should be changed 
every three to six months.  When the old cartridges have been removed, the system should be 
cleaned  and  sanitized  with chlorinated water before the new cartridges are installed. 

 

Dependent upon local water conditions, your membrane should have a life expectancy of 1-5 
years

.  

More severe water conditions (iron, hardness) may shorten this significantly; soft water 

sources may allow a membrane life of up to 8 years.

  

 

Q: When should the membrane be changed? 

If you notice gradually decreasing production from your system, differing taste to your drinking 
water or a white scale forming on

 

pans or dishes, it probably means that your membrane is 

deteriorating and is losing its effectiveness.   You may purchase a pocket TDS meter from your 
dealer - this is the best way to assure you system is operating efficiently. (The RO405400TNX 
models come with a TDS meter preinstalled). 

Содержание VECTAPURE NX RO4053HNX

Страница 1: ... THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN ANNUAL PREVENTATIVE MAINTENANCE INSPECTION BY A WATER PROFESSIONAL IS RECOMMENDED TO ENSURE TROUBLE FREE AND CONTINUOUS OPERATION ...

Страница 2: ...d a plastic tube As the raw water passes across the surface of the membrane only pure water molecules are allowed to pass through and collect in the tube while all other mineral and contaminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Vectapure NX RO system use Vectapure NX system uses 5 stages of treatment to produce your drinking w...

Страница 3: ...NS AND CHANGE FILTER CARTRIDGES AT RECOMMENDED INTERVALS Q What other contaminants does reverse osmosis remove The combined filtering and RO processes in your system will remove more than 98 of many organic compounds including THMs chloroforms DBCP lindane TCE trichloroethylene PCE tetrachloroethylene carbon tetrachloride and chlorine Conservatively Vectapure TFC membranes will remove the followin...

Страница 4: ...r will allow more production overnight A larger holding tank available from your dealer will allow for more water to be on hand Booster pumps will also increase daily production Q What is the standard warranty with the Vectapure NX system Every Vectapure NX system comes with a standard one year limited warranty on all parts and repair labour A detailed warranty card is included with the unit You m...

Страница 5: ...e 12 litre 3 2 gallon RO holding tank One Leak Stop flow interrupter One shock arrestor pressure regulator device Step 1 Selecting the System Location 1 This reverse osmosis system is designed for installation under a sink It can however be mounted anywhere within 20 feet of the faucet such as the basement or adjoining utility room Keep in mind that filter housings will need periodic replacement a...

Страница 6: ...7 10 PSI Adjust if necessary DO NOT EXCEED RECOMMENDED TANK INFLATION PRESSURE UNIT WILL FAIL TO OPERATE CORRECTLY 4 You will need the following tools An electric drill a carbide bit a carbide bit a 1 8 carbide bit a pencil a small adjustable crescent wrench a sharp knife X Acto type knife is best Teflon plumbing tape adjustable pliers a rat tail file a center punch a medium flat head screwdriver ...

Страница 7: ...inless sink go to Step 4 5 3 If you have a concrete sink with a thickness of less than 1 the faucet can be mounted directly to sink If the thickness exceeds 1 the faucet must be mounted directly on the countertop or a faucet with an extended shank must be used Tool substitution Use a 5 8 masonry bit to drill the concrete sink 4 If you have a porcelain enamel or ceramic sink it is strongly recommen...

Страница 8: ...e push on drain port using instructions in Step 8 below Do not attach poly tube at this time Figure 3 Step 6 Install the Tank Valve Preparing the Storage Tank 1 Wrap the threaded storage tank nipple with two wraps of Teflon tape Thread on tank shut off valve until snug Using the wrench turn an additional turn DO NOT OVER TIGHTEN Open tank valve to the fully open position Step 7 Mounting the RO Uni...

Страница 9: ...vice included in kit 2 Connect the black tube marked to drain to the Drain Saddle push on connection your black drain tube is pre attached to your RO Please note that the drain line flow restrictor has been installed INSIDE the black drain tube at the waste elbow on the membrane housing Place the storage tank in the location you have chosen for it Using the clear tube connect the system fitting ma...

Страница 10: ...oints if necessary 2 If a booster pump kit was installed insert the plug into a standard wall receptacle System pump will switch on and begin to operate 3 Close the storage tank valve and open the faucet Let the system operate for about 10 minutes or until product water drips out of faucet Check for leaks again and fix if necessary DO NOT USE ANY WATER FROM THE SYSTEM UNTIL THE NEXT STEP IS COMPLE...

Страница 11: ...on the cold water supply valve and faucet let system fill up with chlorinated water Wait until water flows from faucet then close faucet to allow tank to fill up Wait approximately 5 minutes 4 Turn the cold water supply valve OFF Allow the system to stand for 1 hour 5 Open the faucet and allow the system to completely drain Disconnect the elbow fittings from the cleaning housing and put the origin...

Страница 12: ...lose the faucet and allow the tank to fill up again Your Warranty Keep your bill of sale and your warranty certificate included in this kit This is needed to claim any parts or repair service during the warranty period Read the document completely for warranty claim instructions BE SURE TO RETURN THE VECTAPURE WARRANTY CARD LOCATED IN YOUR LITERATURE KIT THIS IS NECESSARY TO VALIDATE YOUR PRODUCT ...

Страница 13: ... EZT141414DT 19 Water supply adapter ROTF3814 NS Leak Stop flow interrupter LS141KAD NS TDS Monitor HMDM2 RO405400TNX only NS PRV shock arrestor REGP1414E Vectapure NXTM KEY DESCRIPTION PART NUMBER COMMENT KEY DESCRIPTION PART NUMBER COMMENT 1 Filter housing HA10W 10 Post carbon filter AIC10EZ 2 Cartridge 5 mic sediment PP1005 11 Check valve A4CV4 Cartridge Carbon CBC5CTO3 12 4 way shutoff valve R...

Страница 14: ...13 VECTAPURE NX RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT ...

Страница 15: ...14 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ...

Страница 16: ...15 VISIT THE WATERITE TECHNOLOGIES WEBSITE FOR INFORMATION CONSUMER ONLINE REPLACEMENT PARTS AND PRODUCT UPDATES AT www waterite com WATERITE INC Winnipeg Manitoba Canada www waterite com ...