6
6. Install new plumbing as shown in figure 1. Note: If installing a pre-filter, use a
5 micron filter and ensure the direction of water flow is correct.
Figure 2.
WARNING:
If soldering copper pipes, do not allow heat near plastic or nylon threads
or fittings.
7. Remove the electrical end caps. Note that the quartz sleeve has not been
factory installed.
Figure 3.
Slide the quartz sleeve into the chamber until about 1” (2.5 cm) protrudes
from the ends. Slide one of the supplied O-rings over the end. Tighten the