The Operating Menu….
Push any key to wake the display which will show the Home Page. You can then navigate from left to right to six menu pages:
OVERRIDE PAGE (LEFT ARROW KEY):
Pressing OK will allow unlimited use of water for a selected length of time up to 45 minutes.
The
controller will revert to normal operation after this time has ended.
The override can be cancelled at any time by using the left arrow key and
pressing OK when on this page.
HOME PAGE (ANY KEY):
This page is the first page to be displayed. Using the navigation keys, you can change the guard level between high and
low, open and close any valves and check the status of each channel. Each channel will show either:
•
OK:
Valve(s) open, no unusual water usage.
•
CLOSED:
Valve(s) manually closed, to do this press OK on selected channel.
•
HI CLOSE
: Only when the Series 7 is set to close the valve during high guard periods.
•
LEAK CLOSED:
Valve(s) automatically closed. Water limits have been exceeded and a leak has been detected.
Guard levels can be manually changed outside set times by pressing OK, guard level will then show either
MANUAL HI
or
MANUAL LOW.
MODE PAGE (RIGHT ARROW KEY):
The mode can be either
PERMANENT HIGH GUARD
or
NORMAL
where the guard levels change as
selected in the Guard menu.
POWER
display is either mains or backup battery. This page also displays the meter readings.
AUDIT PAGE (RIGHT ARROW KEY x 2):
The audit page records the maximum and minimum litres of water used in a period. Depending on the
system setting, the period can be 1/2 Hour, 1 Hour Guard Period or 24 Hour.
EVENTS LOG PAGE (RIGHT ARROW KEY x 3):
The events log page records all major events in reverse order. Each event is time and date
stamped and includes:
•
LEAK DETECTED
•
ACCESS GUARD MENU
•
USER OPENED VALVE 1
•
CONTROLLER STARTUP
SYSTEM INFORMATION (RIGHT ARROW KEY x 4):
This page displays system information and Waterguard contact details for customer support.
Power Loss….
In the event of any mains power loss the Series 7 is equipped with a backup battery which will continue to provide uninterrupted power for at least
12 months up to 5 years.
Maintenance….
This system requires minimal maintenance
.
In hard water areas it is recommended that any connected valves are dismantled and cleaned with
limescale remover every 12 months as build up can cause the valve operation to fail.
Reinstating the Water Supply….
Ensure to check for leaks before reinstating the water supply, if an alarm persists without a leak consider increasing litre allowance in the guard
menu:
1.
From the controller:
Access the Operating menu by pressing any button, navigate to the channel which has closed (LEAK CLOSED)
and press the OK button to open the valve.
2.
From the valve:
All solenoid valves up to 2” include a manual override. Ensure the override is adjusted by a competent person.
For unlimited water usage:
Access the Operating menu by pressing any button, push the left arrow button and OK to start manual override,
override time determined in Guard menu.