How Your Econoflo MINI SXT Water Conditioner Works
Hard water enters your home through the main supply line, enters the softener and passes down through a resin mineral bed
which softens the water. An ion exchange process takes place in which the resin beads capture and hold calcium and magnesium,
the hardness minerals, while the water takes on sodium ions. The soft water then flows into your household water line.
In normal operation, the Time of Day display will alternate being viewed with the Volume Remaining display. This display
will be in gallons, liters or cubic meters. As treated water is used, the Volume Remaining display will count down from a
maximum value to zero or (---). Once this occurs, a regeneration cycle will be initiated at the Set Regeneration Time. Water
flow through the valve is indicated by the Flow Indicator that will flash in direct relationship to flow rate.
Example
833 Gallons of Treated
Water Remaining
0 Gallons of Treated
Water Remaining
Control Operation During Regeneration
In regeneration, the control will display a special regeneration display. In this display, the control will show the
current regeneration step number the valve is advancing to or has reached and the time remaining in that step. The
step number displayed will flash until the valve has completed driving into this regeneration step position. Once all
regeneration steps have been completed, the valve will return to Service and resume normal operation.
Example
Less than 6 minutes
remaining in Regen
Step Rapid Rinse
Pushing the Extra Cycle Button during a regeneration cycle will immediately advance the valve to the next cycle step
position and resume normal step timing.
1
5
Performance
*Items include brine tank grid.
EFC indicate cabinet model, EFT indicate twin tank model
Maximum Water Temperature = 110°F (43°C)
Maximum Operating Pressure = 100 PSIG (689 kPa)
Voltage = 24V / 60 Hz (120V to 24V wall mount transformer included)
Pipe Size = 3/4”
• At the stated service flow rates, the pressure drop through these devices will not exceed
15 psig.
• Changing salt settings from factory setting may require changing injector sizes to
achieve stated capacities
• The manufacturer reserves the right to make product improvements which may deviate
from the specifications and descriptions stated herein, without obligation to change
previously manufactured products or to note the change.
PM Indicator
PM Indicator
Flow Indicator
(Flashing with water flow)
Flow Indicator
(Flashing with water flow)
Model Number
Pipe
Size
(Inches)
Flow Rates USGPM
Capacity - Grains (ppm)
Mineral
Tank Size
(Inches)
Installation Space
W x D x H
(Inches)
Salt
Capacity
(lbs.)
Shipping
Weight
(lbs.)
Service Backwash @ 3 lbs
/cu.ft
@ 6 lbs/
cu.ft
@ 12 lbs
/cu.ft
EFCMINI-17SXT
3/4"
10
2
5,500
8,500
17,000
10X18
13.5 x 22.5 x 27
75
40
EFCMINI-22SXT
3/4"
10
2
7,000
11,000
22,000
10X18
13.5 x 22.5 x 27
75
40
Please Note:
Attach the supplied overflow fitting and drain tubing at the
pre-drilled hole on the side of the softener cabinet.