WaterGroup Econoflo ECS20 Скачать руководство пользователя страница 10

Operation During A Power Failure 

In the event of a power failure, the valve will keep track of the time and day for 48 hours.  

The programmed settings are stored in a non-volatile memory and will not be lost during a 
power failure.  If power fails while the unit is in regeneration, the valve will finish regenera-

tion from the point it is at once power is restored.  If the valve misses a scheduled regen-
eration due to a power failure, it will queue a regeneration at the next regeneration time 

once power is restored. 

Main Display 

When power is supplied to the control, the screen will display TIME OF DAY, GALLONS RE-

MAINING, and DEALER NAME and PHONE NUMBER. 

The brine tank is equipped with a safety float which prevents your brine tank from overfill-

ing as a result of a malfunction such as a power failure.  

Safety Float 

New Sounds 

You may notice new sounds as your water softener operates. The regeneration cycle lasts 

up to 180 minutes. During this time, you may hear water running intermittently to the drain. 

About The System 

When the system capacity is near exhausted, a regeneration is necessary to restore the sys-

tem to full capacity.  The table below explains the regeneration steps. 

Regeneration Process 

Step

Name

Description

#1

Back

 

Wash

Fresh

 

water

 

is

 

introduced

 

to

 

the

 

bottom

 

of

 

the

 

tank

 

flowing

 

upwards

 

expanding

 

the

 

ion

 

exchange

 

resin

 

to

 

rinse

 

out

 

any

 

dirt

 

or

 

small

 

particles

 

to

 

the

 

drain

 

and

 

to

 

un

compact

 

the

 

bed

 

to

 

restore

 

full

 

service

 

flow

 

rates.

#2

Brine

The

 

brine

 

solution

 

is

 

introduced

 

slowly

 

from

 

the

 

top

 

of

 

the

 

tank

 

flowing

 

down

 

through

 

the

 

ion

 

exchange

 

resin

 

pushing

 

the

 

hardness

 

out

 

to

 

drain

 

and

 

restoring

 

system

 

capacity.

#4

Rinse

Fresh

 

water

 

is

 

introduced

 

from

 

the

 

top

 

of

 

the

 

tank

 

flowing

 

down

 

through

 

the

 

ion

 

exchange

 

resin

 

rinsing

 

any

 

excess

 

brine

 

solution

 

out

 

to

 

the

 

drain.

#5

Refill

Fresh

 

water

 

is

 

added

 

to

 

the

 

salt

 

tank

 

to

 

prepare

 

and

 

insure

 

fully

 

saturated

 

brine

 

for

 

the

 

next

 

regeneration.

  

10  

Содержание Econoflo ECS20

Страница 1: ...EFORE YOU BEGIN INSTALLATION READ THIS ENTIRE MANUAL THEN OBTAIN ALL THE MATERIALS AND TOOLS 1 Avoid pinched o rings during installation by applying provided with install kit NSF certified lubricant to all seals 2 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Tested and Certified by the...

Страница 2: ... water that is microbio logically unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire softener for any shipping damage or parts loss Also note dam age to the shipping cartons Contact the transportatio...

Страница 3: ... by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pressure may exceed the maximum Use a pressure reducing valve to reduce the pressure Softener resins may degrade in the pres ence of chlorine or chloramines above 2 ppm If you have chlorine or chloramines in excess of this amount you may experi ence reduced life of the resin ...

Страница 4: ...optional Nugget or pellet water softener salt is needed to fill the cabinet or brine tank Water Temperature Min 39 F Max 100 F Operating Pressure Min 35 PSI Max 125 PSI Voltage 110 volts standard Units contain 8 Super Capacity Ion Exchange Resin At the stated service flow rates the pressure drop through these devices will not exceed 15 psig Changing salt settings from factory setting may require c...

Страница 5: ...e war ranty Put the softener in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to plug the in cluded transformer into is needed within 6 feet of the softener The transformer has an attached 6 foot power cable Extension cables are available Be sure the electric outlet and transformer are in an in s...

Страница 6: ...is could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or floor drain This can be ran up overhead or down along the floor If running the drain line more than 20 ft overhead it is recommended to increase the hose size to 3 4 NEVER MAKE A DIRECT CONNEC TION INTO A WASTE DRAIN ...

Страница 7: ...Installation Twin Tank 7 ...

Страница 8: ...e RINSE position Check the drain line flow Allow the water to run for 3 4 minutes or until the water is clear 6 Press any button to advance to the REFILL position Check that the valve is filling wa ter into the brine tank Allow the valve to refill for the full amount of time as dis played on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advan...

Страница 9: ... MANUAL REGEN key again 1 Press SETTINGS to advance to the TIME of DAY TIME of DAY will flash Press Up and Down key to adjust the TIME of DAY Press and Hold UP or DOWN key to quickly ad vance the hours and minutes When desired time is displayed press SELECT to Ad vance to the HARDNESS setting 2 HARDNESS will flash Press the UP or DOWN key to adjust HARDNESS Min 1 Max 199 When desired hardness in g...

Страница 10: ...s your water softener operates The regeneration cycle lasts up to 180 minutes During this time you may hear water running intermittently to the drain About The System When the system capacity is near exhausted a regeneration is necessary to restore the sys tem to full capacity The table below explains the regeneration steps Regeneration Process Step Name Description 1 Back Wash Fresh water is intr...

Страница 11: ...ng the water heater This is why automatic regeneration is set for sometime during the night and manual regenerations should be performed when little or no water will be used in the household Normal regeneration time is 2 00 AM System Configuration Injector and Drain Line Flow Control Suggested Softener Valve Configurations Tank Size Diameter Injector Set Brine Line Flow Contol BLFC Drain Line Flow...

Страница 12: ...nly NUGGETor PELLET water softener salt Check the salt level monthly It is impor tant to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt directly into the brine tank Be sure the brine well cover is on and fill only to the height of the brine well Bridging Humidity or wrong type of salt may create a cavity between the water and the salt This ac ti...

Страница 13: ...y opening a cold soft water faucet 2 Using a screwdriver remove the two screws holding the injector cover to the control valve body 3 Carefully remove the assembly and disassemble as shown above The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Re move the injector throat the same way 4 Carefully flush all parts including the screen Use a mild...

Страница 14: ...Replacing Drain Line Flow Control DLFC 1 Remove the red clip that secures the drain line elbow 2 Remove the BLFC washer from the elbow fitting 3 Reassemble using the reverse procedure 14 ...

Страница 15: ... storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid Sanitizer Concentrate Item 50032 Softener Sanitizer 0 25 fl oz 24 Pack 1 Be sure to complete all installation steps including programming 2 For effective and complete sanitization Sani System Liquid Sanitizer Concentrate is rec ommended Pour...

Страница 16: ...uantity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP D 2 60010046 BYPASS SS CLIP E 2 60010047 BYPASS SS SCREW F 2 REPLACEMENT PARTS CONNECTORS 16 ...

Страница 17: ...Control Valve Exploded View 17 ...

Страница 18: ...18 05056044 Adaptor Clip 2 A19 05056090 Screw ST4 2 13 Hexagon with Washer 2 A20 21709003 Secure Clip 2 A21 05056140 Valve Connector 1 A22 05056065 O ring φ23 6 2 65 2 A23 21319006 Screw Adaptor 2 A24 26010103 O ring φ25 3 55 1 A25 07060007 Valve Bottom Connector 1 A26 13000426 Screw ST2 9 13 Large Wafer 2 A27 05056038 Drain Fitting 1 A28 26010003 O Ring φ18 2 65 1 A29 05056036 DLFC Button Retaine...

Страница 19: ...Power Head Exploded View 19 ...

Страница 20: ...T2 9 10 5 B16 5056504 Bnt165 Pcb 1 B17 5056500 Bnt165 Front Cover 1 5056505 Bnt165 Operation Label 1 5056506 Bnt165 Regen Label 1 B18 5056509 Screw ST2 9 10 CSK 2 B19 5056082 Screw M3 5 2 B20 5056510 Motor 12v 2rpm 1 11700005 Wire Connector 2 B21 5056045 Motor Mounting Plate 1 B22 5056501 Bnt165 Drive Gear 1 A04 5010081 Bnt65 Piston Rod 1 B23 5056002 Idler Gear 1 B24 5010031 Meter Assembly 1 50100...

Страница 21: ... flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean parts 4 Unit not drawing brine Check for vacuum leak in brine line connections 1 Drain line flow control is plugged Clean parts 2 Injector or screen is plugged Clean parts 3 Inlet pressure too low Incre...

Страница 22: ... a result of misuse misapplication neglect alteration accident installation or operation contrary to our printed instructions damage to ion exchange resin and seals caused by chlorine chloramines in the water supply or dam age caused by any force of nature is not covered in this warranty We will repair or replace defective parts if our warranty department determines it to be defective under the te...

Отзывы: