background image

185HEDP

 

DUAL

 

PASS

 

Hardness

 

Reduc on

 

System

 

Owners Manual 

REVISION # 0 
REVISION DATE 

0

2

/

19

 54833-1 

1. Read

 

all

 

instruc ons

 

carefully

 

before

 

opera on.

2. Avoid

 

pinched

 

o

rings

 

during

 

installa on

 

by

 

applying

 

(provided

 

with

 

install

 

kit)

 

NSF

 

cer

fi

ed

 

lubri

cant

 

to

 

all

 

seals.

 

3. This

 

system

 

is

 

not

 

intended

 

for

 

trea ng

 

water

 

that

 

is

 

microbiologically

 

unsafe

 

or

 

of

 

unknown

 

quality

 

without

 

adequate

 

disinfec on

 

before

 

or

 

a er

 

the

 

system.

New Style Parallel Tank Connector 

Содержание 185HEDP

Страница 1: ...y before opera on 2 Avoid pinched o rings during installa on by applying provided with install kit NSF cer fied lubri cant to all seals 3 This system is not intended for trea ng water that is microbio...

Страница 2: ...treating water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to mini...

Страница 3: ...Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night t...

Страница 4: ...rate may affect capacity and efficiency performance The manufacturer reserves the right to make product improvements which may deviate from the specifications and Specifica ons WG185HEDP 100 WG185HED...

Страница 5: ...ot covered by the war ranty Put the softener in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to...

Страница 6: ...his could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This...

Страница 7: ...7 Installation...

Страница 8: ...or the full amount of time as dis played on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve...

Страница 9: ...daily use and the reserve ca pacity of the system SALT SETTING There are 3 settings to choose in the MENU SET TINGS These settings will determine the salt dosage and capacity for the system For SIM un...

Страница 10: ...of the parallel tank adaptor used in our dual tank products i e BIF BAF HTO HEDP etc has been redeveloped This new shorter version will also change the New flow directions OUT IN New Style Parallel T...

Страница 11: ...flows upwards in the tank 2 regenerating the media bed It then travels to tank 1 through the center of the distribution tube and flows upwards in tank 1 and then out to the drain Settle Rinse During...

Страница 12: ...ll pause on the Date and Time page for 5 seconds Then it will continually scroll through all of the system diagnostic display pages Depending on the Valve Type some pages will not be dis played To man...

Страница 13: ...70 of the required fresh water is added in Step 5 in the previ ous regenera on The default brine making me is 30 minutes 2 Brine The brine solu on is introduced slowly to the bo om of the tank flowin...

Страница 14: ...Use only crystal water softener salt Check the salt level monthly It is important to main tain the salt level above the water level To add salt simply lift the salt lid and add the salt directly into...

Страница 15: ...ontrol valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Re...

Страница 16: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Страница 17: ...a to form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid...

Страница 18: ...18 Brine Tank Res Up Feeder Assembly Optional Step 3 Install brine well Feed wick from feeder into the opening in the brine well cap...

Страница 19: ...19 Main Repair Parts Connectors A A A B D F E A C...

Страница 20: ...STON ASSEMBLY 60010035 INJECTOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032...

Страница 21: ...A19 1 5030013 O Ring 30 2 65 A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A2...

Страница 22: ...22 Power Head Exploded View...

Страница 23: ...3000426 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT85 Mounting B11 1 5031009 BNT85HE Brine Gear Upflow B12 1 5010023 Magnet 3 2 7 B13 1 505614...

Страница 24: ...24 Trouble Shooting...

Страница 25: ...t mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifications and n...

Отзывы: