![WaterCop WPACT12V Series Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/watercop/wpact12v-series/wpact12v-series_owners-manual-and-installation-manual_874867007.webp)
7
Programming Wireless Sensors
Plug the WaterCop® Pro power supply into a nearby
115 VAC outlet.
Depending upon the position of the
valve, the Actuator may initially turn the valve when
first powered.
BE EXTREMELY CAREFUL TO KEEP
FINGERS AND OTHER ITEMS OUT OF THE VALVE.
The display will read WaterCop NORMAL.
•
To add sensor #1, Press MODE twice (DEVICE ADD
will display on the LCD).
•
Press CLOSE once (DEVICE #1
ID= will display on
the LCD).
•
Short (using a conductive metal surface) one sensor
probe on each sensor by touching the leads with metal.
Do not get the sensor wet – it must be shorted.
The
sensor will beep and the LCD will display SEN #2
SHORT 2, then remove the short and LCD will display
DEVICE STATUS SENSOR #1 OK!
•
To add sensors #2 through #45:
If time has passed,
the Water Control Panel LCD will revert to ready mode
displaying
WaterCop NORMAL.
To add more sensors,
you will need to return to program mode and repeat
steps used to add sensor #1. If LCD screen reads
SENSOR #1 OK!, push CLOSE to add the next
wireless sensor.
•
Repeat above steps for all of your wireless sensors,
taking care to program them in the same order as
labeled.
When finished, Press MODE three times to
return to the NORMAL mode.
To Remove Sensors
If you need to remove a wireless sensor for any reason,
follow these instructions:
•
Press MODE three times (DEVICE REMOVE will
display on the LCD).
•
Press CLOSE to cycle through the loaded sensors to
choose the sensor(s) you wish to remove.
•
Press OPEN to remove the selected sensor from the
Water Control Panel’s memory.
•
Press MODE one more time to return to the main
screen (WaterCop NORMAL).
•
Hardwired sensors can be removed, however the unit
will need to be reset and all sensors reprogrammed.
Pre-Installation Testing of
WaterCop
®
Pro
Although each unit is pre-tested at the factory, it is
highly recommended that the unit be tested prior to
installation to ensure proper operation in your home.
Operating the valve before connecting it to the water
line will not damage it.
USE CAUTION!
The valve closes with
enough force to cut off a finger. Be
extremely careful to keep fingers and
other items out of the valve.
Wiring Instructions
Water Control Panel
The WaterCop® Pro Actuator comes with a 25', 50'
or 75' cable for wiring into the Water Control Panel.
Following the color code in the wiring diagram, wire
each colored wire into the appropriate terminal.
To wire the Water Control Panel into an alarm system,
wire the two terminals titled ALARM into the security
system. The ALARM relay is a dry contact relay and
will only trip if water is detected or dead battery sensor
has turned the water off and the audial alarm turns on.
It will trip off when the valve is opened after water is no
longer detected. The TROUBLE relay will trip if there is
a short, low battery, or open situation.
If the power cord was removed from its terminals, the
positive wire is the one with the stripe on the insulation.
Do not reverse the polarity of the power cable.
Do not reverse the polarity if using optional adapter! The
positive lead is the one with the stripe on the insulation.