WaterCop WPACT12V Series Скачать руководство пользователя страница 7

7

Programming Wireless Sensors 
Plug the WaterCop® Pro power supply into a nearby 
115 VAC outlet.

 

Depending upon the position of the 

valve, the Actuator may initially turn the valve when 
first powered.

 

BE EXTREMELY CAREFUL TO KEEP 

FINGERS AND OTHER ITEMS OUT OF THE VALVE.

 

The display will read WaterCop NORMAL.

  To add sensor #1, Press MODE twice (DEVICE ADD  

  will display on the LCD).

 Press CLOSE once (DEVICE #1

 

ID= will display on  

  the LCD).

  Short (using a conductive metal surface) one sensor  

  probe on each sensor by touching the leads with metal.

  

 

Do not get the sensor wet – it must be shorted.

 

The  

  sensor will beep and the LCD will display SEN #2  
  SHORT 2, then remove the short and LCD will display  
  DEVICE STATUS SENSOR #1 OK!

  To add sensors #2 through #45:

 

If time has passed,  

  the Water Control Panel LCD will revert to ready mode  
 displaying 

WaterCop NORMAL.

 

To add more sensors,  

  you will need to return to program mode and repeat  
  steps used to add sensor #1. If LCD screen reads   
  SENSOR #1 OK!, push CLOSE to add the next  
  wireless sensor.

  Repeat above steps for all of your wireless sensors,  

  taking care to program them in the same order as  
 labeled.

 

When finished, Press MODE three times to  

  return to the NORMAL mode.

 

To Remove Sensors 
If you need to remove a wireless sensor for any reason, 
follow these instructions:

 Press MODE three times (DEVICE REMOVE will    

  display on the LCD).

 Press CLOSE to cycle through the loaded sensors to  

  choose the sensor(s) you wish to remove.

 Press OPEN to remove the selected sensor from the  

  Water Control Panel’s memory.

 Press MODE one more time to return to the main   

  screen (WaterCop NORMAL).

  Hardwired sensors can be removed, however the unit  

  will need to be reset and all sensors reprogrammed.

 
 
 
 

Pre-Installation Testing of 
WaterCop

®

 Pro

Although each unit is pre-tested at the factory, it is 
highly recommended that the unit be tested prior to 
installation to ensure proper operation in your home. 
Operating the valve before connecting it to the water 
line will not damage it.

USE CAUTION!

 

The valve closes with 

enough force to cut off a finger. Be 
extremely careful to keep fingers and 
other items out of the valve.

Wiring Instructions

Water Control Panel 
The WaterCop® Pro Actuator comes with a 25', 50' 
or 75' cable for wiring into the Water Control Panel. 
Following the color code in the wiring diagram, wire 
each colored wire into the appropriate terminal.

To wire the Water Control Panel into an alarm system, 
wire the two terminals titled ALARM into the security 
system. The ALARM relay is a dry contact relay and 
will only trip if water is detected or dead battery sensor 
has turned the water off and the audial alarm turns on. 
It will trip off when the valve is opened after water is no 
longer detected. The TROUBLE relay will trip if there is 
a short, low battery, or open situation.

If the power cord was removed from its terminals, the 
positive wire is the one with the stripe on the insulation. 
Do not reverse the polarity of the power cable.

Do not reverse the polarity if using optional adapter! The 
positive lead is the one with the stripe on the insulation.

 

WARNING!

Содержание WPACT12V Series

Страница 1: ...Owner s Manual and Installation Guide The proven leader in household leak protection WaterCop is there when you re not ...

Страница 2: ...splay with back light provides instant feedback of sensor alarm and trouble conditions as well as open close status of the brass valve On Off push buttons for local control of the brass valve Audible alarm sounds when any sensor detects flooding Internal mounting bracket mounts to standard wall boxes for aesthetics and cord management AC DC power converter with 20 cord included Cabling of 25 50 or...

Страница 3: ...rass Valve Full port NSF ANSI 372 approved lead free brass 125 psi cold water designed for placement on incoming water main Wireless Sensor Power using 2 AA alkaline batteries or optional AC DC power converter sold separately Batteries will provide backup power to sensors upon loss of electricity Wireless sensors are addressable and supervised for conditions such as water detection sensor short op...

Страница 4: ...ight will signal that the valve is now in the closed position The valve will remain closed until the unit is manually reset through the manual override handle or the OPEN button on the Water Control Panel After the plumbing problem is fixed reset the WaterCop Pro by pressing the OPEN green circle on the face of the Water Control Panel NOTE If major repairs are needed to correct the plumbing system...

Страница 5: ...SEN 2 TEMP 1 ALERT SEN 3 SHORT 2 ALERT SEN 2 OPEN 1 ALERT SEN 2 LOW BAT ALARM SEN 2 DEAD BAT Valve is open and all components functioning properly Water was turned off via local controls Wireless Sensor 1 Probe 1 detected water and turned the valve off Hardwired Sensor from Water Control Panel detected water and turned the valve off Temperature Probe on Sensor 2 has detected ambient temperature wa...

Страница 6: ...e the leak is located or warn you if a sensor requires service low batteries It is important that you introduce each wireless sensor to the WaterCop Pro Water Control Panel and document the sensor the transmitter and the sensor probe together not just the probe number on the transmitter Once placed in location you will also note this information on the Sensor Location Log included Once the wireles...

Страница 7: ...to remove Press OPEN to remove the selected sensor from the Water Control Panel s memory Press MODE one more time to return to the main screen WaterCop NORMAL Hardwired sensors can be removed however the unit will need to be reset and all sensors reprogrammed Pre Installation Testing of WaterCop Pro Although each unit is pre tested at the factory it is highly recommended that the unit be tested pr...

Страница 8: ...to the actual position you noticed Green Open Red Closed Grasp both sides of the housing not the valve with the valve pointing away from you for safety Being very careful not to have your fingers or other objects near the valve openings press the OPEN or CLOSE buttons whichever has the unlit light next to it You will hear the motor change the valve position Again look into the threaded end of the ...

Страница 9: ...l does not make the valve close physically remove it from its installed location and place it next to the Water Control Panel Repeat test If the sensor operates properly when it is closer to the Water Control Panel but not when it is installed at its remote location try moving the sensor to a different position or try a different wireless sensor Some possible causes of signal reduction are steel c...

Страница 10: ...nt the battery power reaches a critically low status a CLOSE signal will be transmitted to the WaterCop valve as a precaution After replacing batteries re test each unit in its regular location Periodic testing of sensors is required to monitor proper power and function Installation Procedure Indoor vs Outdoor Selection of WaterCop Pro Valve Installation Sites The WaterCop ready Ball Valve should ...

Страница 11: ...tance from end to end of valve assembly once fittings are secure For tube outside diameter subtract for tube outside diameter subtract from your valve assembly measurement This is the length of the section of tubing to be cut out of the existing line The piece of existing tubing is shorter than the measured length so that the tube ends extend into the compression fittings 3 Select the location for...

Страница 12: ...he WaterCop Pro to return water service Unplug the Water Control Panel from its power source The valve may be manually operated by turning the manual override handle in the direction indicated on the Actuator General Safety Information Warnings and Precautions The motorized drive unit case is not capable of supporting any loads Do not attempt to use the unit as a step This will cause damage to the...

Отзывы: