WaterCop PRO Скачать руководство пользователя страница 4

INSTALLATION GUIDE
Important!

Adherence to all local and municipal building, plumbing 

and electrical codes as they pertain to the installation of 

the WaterCop

®

 PRO System is of utmost importance. 

Codes  in  some  areas  may  require  that  a  licensed 

plumber be employed to do the installation, or that the 

proper  permits  be  obtained  prior  to  any  installation. 

Even if local codes do not require a licensed plumber to 

do the installation, it is necessary that the installer has 

a  professional  level  of  competence  in  both   plumbing 

and  electrical  skills  to   perform  the   installation.  These 

instructions assume this level of knowledge and skill. If 

in doubt, use a licensed  professional.

Common Displays on WaterCop

®

 PRO

Valve is open and all 

components functioning.

Water was turned off via local 

controls.

Flood sensor #1 (probe 1) 

detected water and turned valve 

off.

#2 hard wired sensor from 

monitoring station detected 

water and turned valve off.

Probe on sensor #3 (probe 2) 

is shorted. Water is still on. 

Probe needs to be checked 

and repaired to allow proper 

function.

Probe on sensor #2 is cut or 

disconnected. Water is still on. 

Probe needs to be repaired 

or replaced to allow proper 

function.

Monitoring station has lost 

power or is out of range.

Battery in sensor #2 is low and 

needs to be replaced.

These are the text display codes on both the WaterCop

®

 

PRO valve and monitoring station (optional).

4

WATERCOP

NORMAL

WATERFCOP

WATER IS OFF

! ALARM !

SENSOR #1 WET 1

! ALARM !

WIREPANEL WET 2

***ALERT***

SENSOR #3 SHT 2

***ALERT***

SENSOR #2 OPN 1

***ALERT***

WIREPANEL LOST?

***ALERT***

SENSOR #2 BAT

Flow Data

Valve Size Cv = Gpm flow @ 1 PSI pressure drop

1/2" NPT  

19

3/4" NPT 

34

1" NPT  

52

1-1/4” NPT 

77

For cold water applications.

FCC Information

This  equipment  has  been  tested  and  found  to 

comply  with  the  limits  for  a  class  B  digital  device, 

pursuant  to  part  15  of  the  FCC  Rules.  These  limits 

are designed to provide reasonable protection against 

harmful  interference  in  a  residential  installation.  This 

equipment  generates,  uses  and  can  radiate  radio 

frequency  energy  and  if  not  installed  and  used  in 

accordance  with  the  instructions,  may  cause  harmful 

interference to radio communications. However, there 

is  no  guarantee  that  interference  will  not  occur  in  a 

particular  installation.  If  this  equipment  does  cause 

harmful  interference  to  radio  or  television  reception, 

which can be determined by turning the equipment off 

and  on,  the  user  is  encouraged  to  try  to  correct  the 

interference by one or more of the following measures:

 Reorient or relocate the receiving antenna.

 Increase the separation between the equipment and 

receiver.

 Connect  the  equipment  into  an  outlet  on  a  circuit 

different from that to which the receiver is connected.

 Consult the dealer for help.

Operation  is  subject  to  the  following  two  conditions: 

(1)  this  device  may  not  cause  interference,  and  (2) 

this  device  must  accept  any  interference,  including 

interference  that  may  cause  undesired  operation  of 

the device.

The user is cautioned that changes and modification 

made to the equipment without the approval of the 

manufacturer  could  void  the  user’s  authority  to 

operate this equipment.

LIMITED WARRANTY

DynaQuip Controls Corporation warrants the electrical 

components  of  the  WaterCop

®

  PRO

 

System  to  be 

free from defects in material and workmanship under 

normal use and if properly installed for a period of two 

years from the date of  purchase. If found to be defective 

as mentioned above, it will be replaced or repaired if 

returned prepaid along with proof of date of purchase. 

This shall  constitute the sole remedy of the purchaser 

and the sole  liability of DynaQuip Controls Corporation. 

To the extent  permitted by law, the foregoing is exclusive 

and  in  lieu  of  all  other  warranties  or  representations 

whether  expressed  or  implied,  including  any  implied 

warranty of merchantability or fitness. In no event shall 

DynaQuip Controls Corporation be liable for special or 

 consequential damages.

The  WaterCop

®

  PRO

 

brass  ball  valve  has  a  lifetime 

warranty.

Содержание PRO

Страница 1: ...s of electricity Wireless sensors are addressable and supervised for conditions such as water detection power lost sensor short open and low battery Ten foot sensor cord allows optimal sensor placement Flood sensors can support one or two sensor wires Each WaterCop PRO actuator valve can support up to 45 wireless sensors Range Enhancing Repeater Enhances transmission range of wireless sensors Plug...

Страница 2: ...tration See Installation section for details on sensor installation Hard Wired Sensors Ten foot white cord with single sensor PRO sensors are easily secured to floor using mounting holes Sensors provide the same feedback to monitoring station as the wireless WaterCop PRO sensors Use hardwired censors for convenience or if conditions prevent wireless communication Sensors sold individually and can ...

Страница 3: ...e WaterCop PRO and the valve closes turning off the water source to protect the building from additional water damage The red indicator light will signal that the valve is now in the closed position The valve will remain closed until the unit is manually reset on the WaterCop PRO panel After the plumbing problem is fixed reset the WaterCop PRO by pressing open valve green circle on the face of the...

Страница 4: ...ection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to...

Страница 5: ...you will be able to place them in desired locations to monitor your home or business for water intrusion TO POWER AND PROGRAM WIRELESS SENSORS Powering Sensors Each wireless flood sensor is a battery operated or AC adaptable radio transmitter The units are shipped without batteries Two fresh AA lithium batteries or optional flood sensor AC adaptors are needed to power each unit To install batterie...

Страница 6: ... the WaterCop PRO near your main water line on a sturdy surface It is important that anyone who will be near the valve is aware of the safety precautions and does not insert any object into the valve or handle the valve during the test 2 At one of the locations you have chosen to monitor drop the sensor probe not the mounted transmitter into a cup of water Hold until you hear To add sensors 2 thro...

Страница 7: ...contain Sensors if purchased as part of kit Read Operating Instructions before any installation is attempted All sections of this Installation Guide and 7 accompanying Owner s Manual should be read and completely understood Review Location and Type of Main Supply Line The main supply line should enter the house in either the basement or a crawl space beneath the first floor The water main shut off...

Страница 8: ...Shift tube ends to install WaterCop PRO valve in line 10 Position the unit and tighten compression nuts Hold the fitting with one wrench while tightening the nut with the other Tighten both nuts 11 Plug unit into a proper power source and turn valve to open position open button green light 12 Unplug unit turn water back on and carefully check for leaks 13 Tighten fittings if needed to stop any lea...

Отзывы: