Corrosive Vapors and Possible Causes
Area
Likely Contaminants
Chlorinated swimming
pools and spas
Pool or spa cleaning chemicals. Acids,
such as hydrochloric or muriatic acid.
New construction and
remodeling areas
Glues and cements, construction
adhesives, paints, varnishes, and paint
and varnish strippers. Waxes and cleaners
containing calcium or sodium chloride.
Beauty parlors
Permanent wave solutions, bleaches,
aerosol cans containing
chlorocarbons or fluorocarbons.
Refrigeration plants or
various industrial finishing
and processing plants
Refrigerants, acids, glues and cements,
construction adhesives.
Dry cleaning and laundry
areas
Bleaches, detergents, or laundry soaps
containing chlorine.
Waxes and cleaners containing chlorine,
calcium or sodium chloride.
Table 5.
Chemicals should not be
stored near the heater
installation. Combustion
air can be contaminated
by corrosive chemical
fumes which can void
the warranty.
!
CAUTION
NOTE
Each 90-degree elbow reduces the maximum horizontal PVC air intake duct run by 3.6
metres and each 45-degree elbow in the PVC air intake duct run reduces the maximum
run by 1.8 metres. See the Table 5 above for the maximum lengths using 90-degree
elbows.
I pg 22
Section 3. Installation