PREINSTALLATION INSTRUCTIONS FOR DEALERS:

BYPASS VALVE:

3

The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose,
exchange capacity and salt dose refill time.

The dealer

should read this page and guide the installer regarding hardness, day override, 

and time of regeneration, before installation.

For the installer

, the following must be used:

• Program Installer Settings: Hardness, Day Override (preset to 12 days), and Time of

Regeneration (preset to 2 a.m., with brine tank refill to occur four hours prior; see 
Operating Displays and Instructions for more details)

• Read Normal Operating Displays
• Set Time of Day
• Read Power Loss & Error Display
• Be sure system and installation are in compliance with all state and local laws and regulations.

For the homeowner

, please read operating displays and instructions.

WATER SOFTENERS:

During operation, the normal user displays are 

time of day

or 

gallons remaining before regeneration

will occur. 

Days remaining

is an optional display but is not normally used. Each of these can be viewed by pressing

NEXT

to scroll through them. When stepping through any displays or programming, if no buttons are

pressed within 5 minutes, the display returns to a normal user display. Any changes made prior to the 
5 minute time out are incorporated.

To quickly exit any Programming, Installer Settings, etc., press 

CLOCK

. Any changes made prior to 

the exit are incorporated. If desired, two regenerations within 24 hours are possible with a return to 
the preset program. To do a 

double regeneration

:

1. Press the 

REGEN

button once. “REGEN TODAY” will flash on the display.

2. Press and hold the 

REGEN

button for five seconds until a regeneration begins.

Once the valve has completed the immediate regeneration, the valve will regenerate one more time 
at the preset.

The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure 
in order to perform control valve repairs or maintenance. The 1" full flow bypass valve incorporates four
positions, including a diagnostic position that allows a service technician to have pressure to test a system
while providing untreated bypass water to the building. Be sure to install bypass valve onto main control
valve, before beginning plumbing. Or, make provisions in the plumbing system for a bypass. The bypass
body and rotors are glass-filled Noryl

®

and the nuts and caps are glass-filled polypropylene. All seals are

self-lubricating EPDM to help prevent valve seizing after long periods of non-use. Internal “O” Rings can
easily be replaced if service is required.

The bypass consists of two interchangeable plug valves that are operated independently by red arrow
shaped handles. The handles identify the direction of flow. The plug valves enable the bypass valve to
operate in four positions.

Содержание CSP-1044

Страница 1: ...CareSoft Pro Series Metered Water Softeners For Models CSP 844 CSP 948 CSP 1044 CSP 1054 CSP 1248 CSP 1354 For Cabinet Models CSPC 835 CSPC 935 CSPC 1035...

Страница 2: ...come when installed and operated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any qu...

Страница 3: ...ickly exit any Programming Installer Settings etc press CLOCK Any changes made prior to the exit are incorporated If desired two regenerations within 24 hours are possible with a return to the preset...

Страница 4: ...to the building while not allowing water to exit from the system to the building Fig 3 This allows the service technician to draw brine and perform other tests without the test water going to the buil...

Страница 5: ...to be unscrewed or tightened by hand or with the special plastic Service Wrench CV3193 01 If necessary pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten nuts or caps Do...

Страница 6: ...lamp or jumper wiring NOTE If replacing an existing softener also replace the ground clamps wire If removing a softener replace the piping with the same type of piping as the original to assure plumbi...

Страница 7: ...ilding structure Your softener is equipped with a brine tank safety float which greatly reduces the chance of an accidental brine overflow In the event of a malfunction however an overflow line connec...

Страница 8: ...S Set the amount of hardness in grains per gallon default 20 using the or buttons The allowable range is from 1 to 150 in 1 grain increments Note Increase the grains per gallon if soluble iron is pres...

Страница 9: ...displays One of the displays is always the current time of day The second display shows the current treated water flow rate through the system in Gallons Per Minute The third display is one of the fo...

Страница 10: ...thereafter see Start Up Instructions for regeneration sequence the water softener will deliver water but it will be untreated IMPORTANT With the Dry Salt Storage Feature the brine tank will refill 4 h...

Страница 11: ...er softener include a dry salt storage feature no water in brine tank between regeneration the manufacturer recommends the use of solar salt for best results The brine tank is manufactured for the use...

Страница 12: ...up it could result in a salty water complaint after the first regeneration During the first regeneration the unit will draw out the initial volume of brine regenerant and refill it with the correct pr...

Страница 13: ...any remaining debris and air from the system again 1 Full open a cold water faucet preferably at a laundry sink or bathtub without an aerator 2 Wait two to three minutes or until water runs clear then...

Страница 14: ...remove meter and check for debris D defective meter D replace meter E defective PC board E replace PC board Unit regenerates at wrong time of day A past power outage A reset time of day B incorrect t...

Страница 15: ...circuit board failure _______________ TWIN ALT SYSTEMS Error code 1006 motor ran too long Error code 1007 unexpected stall A valve has just been serviced 1001 A press NEXT and REGEN for 5 seconds or...

Страница 16: ...837 01 CareSoft Pro cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3851WN PC board 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV3002CC Drive assembly CV3186 T...

Страница 17: ...ston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4 20 HE...

Страница 18: ...on Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV315...

Страница 19: ...BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN n...

Страница 20: ...1 0 DLFC for 3 4 elbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162...

Страница 21: ...8 01 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve...

Страница 22: ...grid support 6 needed WC 1 CH1088 Optional Salt grid handle WC 1 CH1072 01 Optional 18 diameter salt grid 1 CH1080 Optional 24 diameter salt grid 1 3 CG21833CB1C00 18 x 33 brine tank black 1 CG21840C...

Страница 23: ...ion Qty 1 CG2197 01 Salt and tank cover must be ordered together 1 2 CG2724HP 01 Windsor cabinet white with black lids 1 3 CH1090 01 Optional salt grid for 8 diameter tank and 4 brine well 1 CH1090 02...

Страница 24: ...1 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assemb...

Страница 25: ...3375 Fitting 2 3 4 JOHN GUEST ELBOW Item No Part No Description Qty CV3007 15 3 4 John Guest elbow assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3790 Fittin...

Страница 26: ...ax Service PSI 8 6 14 1 15 0 Min to Max Working Pressure PSI 30 100 30 100 30 100 Min to Max Operating Temperature F 33 100 33 100 33 100 Max Flow to Drain During Regeneration GPM 1 3 1 7 2 2 Amount o...

Страница 27: ...ponent at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manne...

Страница 28: ...steps as shown to the right Access this mode by pressing NEXT and button simultaneously NOTE Hardness display shows nA if used as a filter If other displays do not appear refer to manual QUICK REFERE...

Отзывы: