Operation

Priming the DuroJet Convertible Shallow Well Jet Pumps

To prevent damage to the pump, do not start motor until pump has been filled with water.

1.  Remove prime plug.

2.  Fill pump and piping completely full of cold water.

3.  Replace the prime plug.

4.  Open a faucet to vent the system.

5.   Start the motor. Water will be pumped within a few minutes. If the pump fails to prime within 5 minutes, stop the motor 

and refill the pump with cold water. The priming time is proportional to the amount of air in the inlet pipe. Refill as often 

as necessary.

6.  Let the system operate for several minutes to flush all pipes.

7.   Close the faucet and allow the pump to build pressure in the tank. When the pressure reaches the cut-out setting, the 

motor will stop.

The system is now in operation and will automatically cycle on demand.

Disconnect power and release all pressure from the system before attempting to install, service, relocate or perform 

any maintenance. Lock the power disconnect in the open position. Tag the power disconnect to prevent unexpected 

application of power.

CAuTioN! Protect pump from freezing during winter conditions.

Draining the DuroJet Convertible Shallow Well Jet Pump

Drain openings are provided on all models. To drain the pump:

1.  Remove the drain fitting and the prime plug to vent the system.

2.  Drain all piping to a point below the freeze line.

Priming and Setting the DuroJet Convertible Deep Well Jet Pumps

When using DuroJet pumps on deep well applications, longer tube for ejector assembly is required. WaterGroup’s part 

number for the long tube is (#302922).

1.  Remove prime plug from the pump discharge.

2.  Fill pump and piping completely full of cold water.

3.  Replace the prime plug 

4.  Make sure that the long tube is replaced with short tube in the ejector assembly.

5.  Start the pump. When the pump is properly primed, a high pressure will show immediately on the gauge.

6.   If no pressure is shown, stop the pump and repeat Steps 1 - 3. Several attempts may be required before the pump is 

primed.

7.   The pressure obtained in Step 6 will be the minimum operating pressure of the pump. 

8.   When the correct pressure is set, close the faucets. Pressure will rise to close the pressure switch and the pump will stop 

automatically.

9.    With the pump primed and set, check operation by opening and closing faucets as necessary, allowing the pump to cycle 

automatically.

NoTe:

 Systems with long offset lines or driven well points may take several attempts to prime. If your pump does not prime 

within one or two minutes, repeat Steps 1 to 3. When the pump is primed and running, check operation by opening and 

closing faucets as necessary, allowing the pump to cycle automatically.

Disconnect power and release all pressure from the system before attempting to install, service, relocate or perform 

any maintenance. Lock the power disconnect in the open position. Tag the power disconnect to prevent unexpected 

application of power.

CAuTioN! Protect pump from freezing during winter conditions.

Содержание 6330

Страница 1: ...n pump body or for deep well installation for water level up to 80 feet with 1 1 4 pipes and injector down in the well A pressure switch and pressure gauge are standard features The pump starts when the pressure drops to a cut in setting 30 psi and cut out setting 50 psi The DuroJet Convertible Jet Pump can be mounted to either a pre charged horizontal pressure tank or used with a pre charged free...

Страница 2: ...e and void the warranty 10 Do not run the pump dry or damage will occur 11 The unit should be connected to a grounded circuit equipped with a ground fault interrupter device 12 Before installing the pump have the electrical outlet checked by a licensed or certified electrician to make sure the outlet is properly grounded 13 Make sure the line voltage and frequency of electrical current supply agre...

Страница 3: ...h setting is 30 psi cut in and 50 psi cut out Wells A new well should be pumped clear of sand before installing the pump Sand will damage the pumping parts and seal The drawdown level of the well should not exceed the maximum rated depth for the pump The capacity of the pump will be reduced and a loss of prime may occur Location Select a location as close to the water supply as possible Be sure to...

Страница 4: ...rating Driven Well or Sandpoint Well 1 Drive the point several feet below the water table Note A packer type foot valve can be installed in the well This type of foot valve allows the well to be filled with water when priming and makes the inlet pipe much easier to test for leaks Follow the manufacturer s instructions when installing the packer type foot valve As an alternative an in line check va...

Страница 5: ...s down in the well This pump is designed for pumping potable water in applications where the water level is up to 80 feet Drilled Well 1 Assemble the foot valve to the ejector The short tube in the ejector assembly needs to be replaced with long tube 302922 2 Connect suction pipe and drive line to the ejector as shown in the diagram on the following page 3 Install the assembly so foot valve is sub...

Страница 6: ...ed The pump should be connected to a separate electrical circuit directly for the main electrical service panel Do not use an extension cord 4 It is mandatory that a permanent ground connection be made from the pump motor to the grounding bar at the service panel Do not connect the pump motor to a power supply until the pump is permanently grounded The ground wire should be copper and at least as ...

Страница 7: ...roJet Convertible Deep Well Jet Pumps When using DuroJet pumps on deep well applications longer tube for ejector assembly is required WaterGroup s part number for the long tube is 302922 1 Remove prime plug from the pump discharge 2 Fill pump and piping completely full of cold water 3 Replace the prime plug 4 Make sure that the long tube is replaced with short tube in the ejector assembly 5 Start ...

Страница 8: ...Open a faucet nearest the tank and allow all water to drain from the tank 2 Measure the tank precharge at the valve stem using a tire gauge 3 If necessary adjust the precharge with an air pump to 2 PSI below the cut in pressure of the pump Lubrication The bearings used in the pumps are lifetime lubricated at the factory and require no additional lubrication Diagnosing Waterlogged Tanks Conventiona...

Страница 9: ...J750 1 10 302911 PLUG DRAIN PRIME DCJ500 750 1 4 18NPT 2 11 302912 O RING DIFFUSER DCJ500 750 OD 34 5 3 5 1 12 302913 O RING HOUSING DCJ500 750 OD 154 5 3 5 1 13 302914 ADAPTER PRESSURE SWITCH DCJ500 750 1 14 302915 NUT ADAPTER PRESSURE SWITCH DCJ500 750 1 15 302916 ADAPTER PRESSURE TUBE DCJ500 750 1 4 18NPT 1 16 302917 PRESSURE SWITCH DCJ500 750 1 17 302918 MECHANICAL SEAL DCJ500 750 1 19 302920 ...

Страница 10: ... 12 2 6 1 0 5 60 0 15 17 3 11 8 5 9 0 5 60 0 16 16 5 11 4 5 7 0 4 60 0 18 15 2 11 1 5 5 0 1 60 0 20 14 7 10 5 5 1 57 0 22 13 4 9 8 4 9 55 0 24 12 9 9 3 4 5 53 0 25 11 5 8 1 4 4 53 0 26 11 1 7 9 4 1 28 10 9 7 6 3 8 30 10 7 6 9 3 7 3 4 HP Jet Pump Lift in Feet 30 40 50 60 70 80 Capacity in USGPM at 20 psi 6 6 6 5 4 3 Capacity in USGPM at 30 psi 6 6 5 4 3 2 Capacity in USGPM at 40 psi 5 4 3 2 1 Capac...

Страница 11: ... and impeller b Check water level in well to see actual pumping level Measure vertical distance to pump and compare to tolerance for pump type c See No 2c above d Compare minimum pressure on which capacity is based with operating pressure shown on gauge e Replace suction and drive lines with larger diameter pipe f Inspect for wear on impeller nose or internal blockage a Nozzle or impeller clogged ...

Страница 12: ...will be made or a replacement pump or part will be supplied free of charge The serial number of the pump must be supplied This warranty does not obligate the manufacturer to bear the cost of field labor or transportation in connection with the replacement or repair of defective parts or units nor shall it apply to any product upon which repairs or alterations have been made unless authorized by th...