Maintenance

This manual is applicable to one of the following model numbers:

RC32-TM, RC40-TM, RC48-TM, RC64-TM, RC80-TM

With minimal care, your system is designed to serve you for many years. While con-
stant attention to your system is not necessary, the following suggestions will insure 
your system’s performance and your convenience and satisfaction.

MAINTENANCE

• Salt in the brine tank is used as a resin ‘cleaner’ to remove contaminants during 

the regeneration process. Check the salt level of the brine tank on a regular basis 
to make sure your system is using salt. Your REIONATOR™ will function properly 
whether the salt tank is near full or near empty, refi ll when necessary.

• Use only premium-grade regenerant salt that is designed specifi cally for use with 

water softeners and conditioners. Sodium (NaCl) salt may be used. Potassium (KCl) 
is recommended in most applications for superior taste, odor, aesthetic and envi-
ronmental benefi ts.

SERVICE ISSUES

• If the Triton control valve system display does not appear, check to make sure the 

system is plugged in and that there is power at the receptacle. If the unit does not 
respond with power present, contact your Water Tech Dealer.

• The manual bypass valve (which is located at the rear of the unit) is designed to 

isolate the unit from the plumbing for servicing or to shut off the water supply to 
the unit in the event of a leak at the conditioner. Consult the operating diagram on 
pages 11-12 of this manual for instructions to position your bypass valve for either 
service or isolation.

• If you experience an extended power outage (over an hour in length), you may need 

to reset the time of day on the Triton control valve. The internal battery is designed 
to retain the time of day for up to 24 hours. There is no need to reset any other 
part of the program as this is kept in non-volatile, permanent memory. Consult the 
programming instructions on page 10 of this manual for instructions to set the elec-
tronic time clock of the Triton control valve.

• If you experience a change in water quality:

1. First check to see if your brine tank is empty (see above). If necessary, 

add regenerant salt.

2. Check to see if your system has power (see above).
3. Check to see if the drain line has a kink that may be restricting fl ow during 

regeneration. Correct, if necessary, or contact your Water Tech Dealer.

2

Specifi cations

Water Tech recommends the use of Potassium Chloride (KCl) as a regenerant salt.

* The effi ciency is only valid at the stated salt dosage and maximum service fl ow.

1

 Softening effi ciency values based on NaCl as the regenerant salt.

2

 Softening capacity values based on NaCl as the regenerant salt.

Effi ciency rated softeners shall have a rated salt effi ciency of not less than 3350 grains 
of total hardness exchange per pound of salt, and shall not deliver more than its 
listed rating. 
MIN/MAX WORKING PRESSURE: 20-125 psi or 138-861 kPa
MIN/MAX OPERATING TEMPERATURE: 40°F-110°F or 4.4-43.3º C
MAX FLOW TO DRAIN DURING REGENERATION: 2.2 gpm or 8.3 l/min
INPUT VOLTAGE: 110-120VAC @ 60Hz
OPERATING VOLTAGE: 12VAC @ 60Hz

13

Model

*

1

 Softening Effi ciency 

@ Stated Salt Setting

(Grains Per Pound)

2

 Softening Capacity 

@ Stated Salt Setting 

(Grains Per Gallon)

Max. Recommended 

Hardness 

(Grains Per Gallon)

RC32-TM

4400 @ 3 lbs.

15,000 @ 3 lbs.

35

RC40-TM

4400 @ 4lbs.

19,200 @ 4 lbs.

45

RC48-TM

4790 @ 5lbs.

22,600 @ 5 lbs.

55

RC64-TM

4790 @ 6lbs.

30,500 @ 6 lbs.

35

RC80-TM

4790 @ 8lbs.

37,400 @ 8 lbs.

45

Model

Max. Recommended 

Flow Rate / 

Service Flow Rate 

(Gallons per minute)

Max. Flow to Drain 

During

Regeneration 

(Gallons per minute) @PSID

Total Bed Depth 

(FT3)

RC32-TM

8.8

2.2

7

0.981

RC40-TM

11.0

2.2

9

1.199

RC48-TM

11.0

2.2

9

1.417

RC64-TM

15.8

3.2

13

1.910

RC80-TM

17.4

4.2

15

2.350

Содержание REIONATOR Classic Series

Страница 1: ...rage as described above Cosmetic damage that does not affect the process functionality of the equipment is not covered Water Tech Industries makes every effort to ensure that all illustrations and spe...

Страница 2: ...4 Specifications The REIONATOR is a DIR demand initiated regeneration softener which complies with specific performance specifications intended to minimize the use of regenerant brine in its operation...

Страница 3: ...hours There is no need to reset any other part of the program as this is kept in non volatile permanent memory Consult the programming instructions on page 10 of this manual for instructions to set th...

Страница 4: ...stem or water quality issues DO enjoy all the benefits of your REIONATOR conditioned water DO NOT hang or stack items on your equipment This may cause an equipment im balance or put a strain on plumbi...

Страница 5: ...control valve during normal operation and this position also allows the control valve to isolate the media bed during the regeneration cycle Figure 2 Bypass Position The inlet and outlet handles point...

Страница 6: ...f a power outage lasting longer than two hours occurs the time of day will flash on and off which indicates the time of day should be reset All other inputs will be retained by the system and will not...

Страница 7: ...y for example a manual regeneration may be initiated to bring the system to full capacity To initiate a manual regeneration at the upcoming preset delayed regeneration time when the regeneration time...

Страница 8: ...ove air check in the brine well The extra gallon is an additional measure for evaporation or loss 6 3 2 gallons of water plus gallon Fill the brine tank with salt We recommend potassium chloride KCl i...

Отзывы: