background image

Water Tec Int’l. Inc.                                                                                                                                                           Version 02A

 

2

This manual includes the most common components and installation specifications.  Please keep 
in mind that Water Tec manufactures many units to customer specifications. If you do not find the 
information that you are looking for in this manual, please contact your local Water Tec dealer.

 

 

TABLE OF CONTENTS 

 

INTRODUCTION TO REVERSE OSMOSIS 

 

 

How Reverse Osmosis Works 

 

 

The Membrane 

 

 

Factors That Affect the Useful Life of a Membrane  

 

 

Effects of Temperature on the Reverse Osmosis Units  

 

 

Some Common Terms and Definitions Related to Reverse Osmosis   

 

 

The Reverse Osmosis System 

 

 

 

 

 

 

 

 

 

Purified Water Storage and Delivery 

 

 

 

 

 

 

 

II 

REVERSE OSMOSIS COMPONENT IDENTIFICATION   

 

      

 

 
III 

GENERAL SYSTEM DIAGRAMS 

 

 

The Compact RO  

 

(CP)   

 

 

 

 

 

 

 

 

The Wall Mount F.G. RO  

(WM)  

 

 

 

                   

 

 

The Wall Mount F.M. RO  

(WMXL) 

 

 

 

 

 

 

 

The Vertical RO   

 

(VXL) 

 

 

 

 

 

 

 

 

The Horizontal RO  

 

(HXXL) 

  

 

 

 

          

 

 

The Horizontal RO  

 

(X) 

 

 

 

 

 

 

 

 

IV 

REVERSE OSMOSIS SET-UP SPECIFICATIONS   

 

 

 

 

 

 

 

REVERSE OSMOSIS SET-UP  
  

 START -UP  

  

 TESTING PROCEDURES   

 

 

 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

               

 
VI 

MEMBRANE INSTALLATION 

 

 

 

 

 

 

 

 
VII 

TROUBLE SHOOTING GUIDE 

 

 

 

 

 

 

 

 

 
VIII  REVERSE OSMOSIS PRE-TREATMENT 

 

 

 

 

 

 

 

 

 

10 
11 
12 
13 
14 
15 
 
16 
 
17 
17 
17-18 
 
 
18 
 
19 
 
20 








 
7-9

 

Содержание CP

Страница 1: ...Water Tec Int l Inc Version 02A REVERSE OSMOSIS SYSTEMS OPERATING MANUAL MODELS CP WMXL WXL VXL HXL HXXL X Water Tec International Inc Tucson Arizona 85714 www water tec com...

Страница 2: ...Life of a Membrane Effects of Temperature on the Reverse Osmosis Units Some Common Terms and Definitions Related to Reverse Osmosis The Reverse Osmosis System Purified Water Storage and Delivery II RE...

Страница 3: ...the side of such membrane materials pure water will pass through leaving most of the impurities behind The rejection of the dissolved ionic material is a function of both molecular weight and ionic c...

Страница 4: ...the water production rate EFFECTS OF TEMPERATURE ON THE REVERSE OSMOSIS UNITS In system design it is very important to consider incoming water temperature The units are rated for a product flow at 77...

Страница 5: ...pressure usually to a vented storage tank In general the unit cannot be operated by opening and closing a valve at the product water line unless a special pressure relief is provided The reason for th...

Страница 6: ...l switches are available from your authorized Water Tec distributor The purified water in the storage tank is distributed to the use points by means of a moderate pressure high capacity centrifugal pu...

Страница 7: ...justing the Recycle Valve 8 located on the front control panel near the Waste Valve Proper recovery must be set according to unit s application 4 PERMEATE PRESSURE GAUGE 0 100 PSI liquid filled panel...

Страница 8: ...re filter is 5 microns This filter is used to catch any particles that may have been missed by the Pre Treatment or any particles that may be released by faulty Pre Treatment Leaving a dirty filter ca...

Страница 9: ...rol box Inlet line voltage routed through a 5 amp fuse and a 15 amp fuse for compacts 19 LIQUID LEVEL CONTROL RELAY AND SWITCH Connection leads are outside of the control box on the top or on the side...

Страница 10: ...Water Tec Int l Inc Version 02A 10 GENERAL SYSTEM DIAGRAMS CP 1 Incoming Feed Water 2 10 PS05 10 Pre Filter 3 10 C1 Pre Filter 4 10 CB10 10 Pre Filter 5 Recycle Needle Valve 1 5 6 7 8 2 3 4 9 10...

Страница 11: ...me 9 Electrical Control Box not shown 10 Rotary Vane Pump and Motor not shown GENERAL SYSTEMS DIAGRAM WM 1 Incoming Feed Water 5 Rotary Vane Pump Pre Filter supplied but not shown 2 Electrical Control...

Страница 12: ...re Tank Optional 4 Motor GENERAL SYSTEM DIAGRAM WMXL 1 Incoming Feed Water 2 Electrical Control Box 2a On Off Switch 2b Power On Indicator 2c Low Pressure Indicator 2d 5amp Fuse 2e OPTION Digital TDS...

Страница 13: ...ing Feed Water and Pre filter not shown 3 Electrical Control Box 3a On Off Switch 3b Power On Indicator 3c Low Pressure Indicator 3d 5amp Fuse 4 High Pressure Pump and Solenoid 5 Control Panel 5a Inco...

Страница 14: ...ntrol Box 3a On Off Switch 3b Power On Indicator 3c Low Pressure Indicator 3d 5amp Fuse 4 Control Panel 4a Permeate Flow Meter 4b Concentrate Flow Meter 4c Incoming Pressure Gauge 4d System Pressure G...

Страница 15: ...w Meter 7f Power Light 7g Low Pressure 7h Over Pressure 7i Fast Flush 7j Cleaning option 7k Power Switch 7l Clean Auto run Keyed Switch 8 Control Panel 8a Pre Filter Gauge 8b Post Filter Gauge 8c Pump...

Страница 16: ...onnections and Voltages All CP and WM Series standard units are 110v 60hz They have a standard 110v 3 prong plug WMXL VXL and HXL Series units are available in 110v 60hz or 220v 60hz single or three p...

Страница 17: ...Turn on the Incoming Feed Water q 5 The Incoming Pressure Gauge should rise above 20 PSI When the incoming pressure reaches approximately 20 PSI the Low Pressure Indicator will turn off q 6 After a d...

Страница 18: ...m the unit to product and waste as the unit drains After the short drain out period the flow should completely stop The Power On Indicator should remain on Reconnect the Liquid Level Switch wires The...

Страница 19: ...e clogged dirty Check replace Low Pressure Switch Check for power replace No high pressure Reject valve open too far Check adjust Reject bypass may be open Check adjust High pressure gauge may be brok...

Страница 20: ...used in areas with higher sediment content Dirty water can clog the pre filter of the R O causing an incoming pressure drop 2 Automatic backwashing carbon filter The reverse osmosis unit CANNOT tolera...

Отзывы: