background image

30119-33      Rev. 1.8/04-14

2

Copyright © 2001-2007 McCrometer.  All written material should not be changed or altered without permission of McCrometer.

The published technical data and instructions is subject to change 

without notice

. Contact your McCrometer representative for current technical data and instructions.

WARRANTY

This Warranty shall apply to and be limited to the original purchaser consumer of any McCrometer product. Meters or instruments defective because of 
faulty material or workmanship will be repaired or replaced, at the option of McCrometer, free of charge, FOB the factory in Hemet, California, within a 
period of one (1) year from the date of delivery.

Repairs or modifications by others than McCrometer or their authorized representatives shall render this Warranty null and void in the event that factory 
examination reveals that such repair or modification was detrimental to the meter or instrument.  Any deviations from the factory calibration require 
notification in writing to McCrometer of such recalibrations or this Warranty shall be voided.

In case of a claim under this Warranty, the claimant is instructed to contact McCrometer, 3255 W. Stetson Ave., Hemet, California 92545, and to provide 
an identification or description of the meter or instrument, the date of delivery, and the nature of the problem.

The Warranty provided above is the only Warranty made by McCrometer with respect to its products or any parts thereof and is made expressly in lieu 
of any other warranties, by course of dealing, usages of trade or otherwise, expressed or implied, including but not limited to any implied warranties 
of fitness for any particular purpose or of merchantability under the uniform commercial code.  It is agreed this Warranty is in lieu of and buyer hereby 
waives all other warranties, guarantees or liabilities arising by law or otherwise.  Seller shall not incur any other obligations or liabilities or be liable 
to buyer, or any customer of buyer for any anticipated or lost profits, incidental or consequential damages, or any other losses or expenses incurred by 
reason of the purchase, installation, repair, use or misuse by buyer or third parties of its products (including any parts repaired or replaced); and seller 
does not authorize any person to assume for seller any other liability in connection with the products or parts thereof.  This Warranty cannot be extended, 
altered or varied except by a written instrument signed by seller and buyer.

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

McCrometer reserves the right to make improvements and repairs on product components which are beyond the Warranty period at the manufacturer’s 
option and expense, without obligation to renew the expired Warranty on the components or on the entire unit. Due to the rapid advancement of meter 
design technology, McCrometer reserves the right to make improvements in design and material without prior notice to the trade.

All sales and all agreements in relation to sales shall be deemed made at the manufacturer’s place of business in Hemet, California and any dispute 
arising from any sale or agreement shall be interpreted under the laws of the State of California.

Содержание TR15

Страница 1: ...TENANCE MANUAL PARTS LIST FEATURING P C CARD MOUNTED OPTIC SWITCH SOLID STATE CONSTRUCTION CURRENT OUTPUT SIGNAL CUBTYPE ACTUATOR SEALED HOUSING OUTPUT SIGNAL CUPTYPE ACTUATOR SEALED HOUSING 3255WEST...

Страница 2: ...ages of trade or otherwise expressed or implied including but not limited to any implied warranties of fitness for any particular purpose or of merchantability under the uniform commercial code It is...

Страница 3: ...unication Lines 10 Printed Circuit Card 11 Replacing Printed Circuit Card XII INSPECTION XIII REASSEMBLY 1 Before Return ofTransmitter XIV INOPERATIVEINSTRUMENTEVALUATION 1 Check All Instruments andTr...

Страница 4: ...the meter is assembled but may be made in the field with the meter stopped i e noflow Dependinguponwhatsituationexists various steps for installation apply and the procedures are outlined below 1 REMO...

Страница 5: ...clevis shaft 28 so that the slot in the clevis coupling 36 is properly engaged with the cross pin in the driven clevis shaft 28 Secure the four mounting screws 37 12 TRANSMITTERWIRING canbeaccomplish...

Страница 6: ...the totalizer bonnet 1 onthetotalizerassembly 4 afterthedesiccantcapsule andthebasecupo ring 6 arereplacedandthenewo ring 6 has beencovered withathickcoatof siliconegrease Besure o ring 6 is on base c...

Страница 7: ...5 and coupling 36 are adjusted correctly and engaged properly with the driven clevis shaft 28 but the meter is not turning them then the meter is the likely cause of the problem 8 SWITCH ACTUATOR 23 i...

Страница 8: ...cup 23 is rotating and the transmitter is away from direct sunlight or other high energy light source replace the circuit card 12 Iftheloopcurrentiswithinasatisfactoryrange 3 00mA 23 00mA and varies...

Страница 9: ...the 115VAC line used for the instrument can be causing the trouble It is suggested the plug from the instrument be tempo rarily transferred to another AC outlet which is on another circuit It has bee...

Страница 10: ...the traditional precaution however other measures must be taken to minimize the effects of electromagnetic interference EMI and radio frequency interference RFI on the operation of the instrument Othe...

Страница 11: ...or checking pulse output at transmitter Black and white wires must be discon nected from transmitter terminal strip for this test Power must be removed from instrument before disconnecting wires BLACK...

Страница 12: ...D POWER SUPPLYVOLTAGE TR15 TR16 TRANSMITTER 4 20 mA OUTPUT WIREDTO A MODEL IN48 10 CHART RECORDER SOLD BEFORE 5 93 NOTE Connections for checking transmitter power supply voltage 24VDC Con nect voltmet...

Страница 13: ...TER 4 20 mA OUTPUT WIREDTO A MODEL IN41 10 CHART RECORDER IN36 1 POWER SUPPLY OUTPUT 24VDC INPUT 115VAC L1 N BLACK G N TB 2 L1 WHITE GRN RED TERM STRIP PULSE BLACK TR15 TR16 4 20mA WIRING DIAGRAM FORT...

Страница 14: ...4V DC power supply and 22 gauge wire we recommend a maximum loop of 5 250 feet Power Power supply Maximum Supply voltage resistance of for loop instruments in loop Variable 12 0VDC 175 Variable 15 0VD...

Страница 15: ...30119 33 Rev 1 8 04 14 15 NOTES...

Страница 16: ...nnet Complete Items 1 thru 6 Totalizer Bonnet Complete Items 1 thru 8 Totalizer Bonnet Assembly Totalizer Bonnet Lid with pin O ring Totalizer Bonnet Screw Bonnet Mounting Totalizer Sub Assembly Less...

Страница 17: ...30119 33 Rev 1 8 04 14 17 TOTALIZER TRANSMITTER MODELTR15...

Страница 18: ...icator Totalizer Bonnet Assembly Indicator Totalizer Bonnet Lid with Pin Screw Bonnet Mounting Screw Bonnet Mounting O ring O ring Bonnet Indicator Totalizer Mechanism Including Dial Specified and Gea...

Страница 19: ...30119 33 Rev 1 8 04 14 19 INDICATOR TOTALIZER TRANSMITTER MODELTR16...

Страница 20: ...1 8 04 14 SPECIFICATIONS INDEX A B RATIO CHANGE GEARS METER SIZE MODEL NO REGISTRATION INDICATOR DIAL GEARING REPAIR RECORD SERIAL NUMBER PURCHASE DATE ODOMETER READING NOTES DATE REPAIR METER LOCATIO...