Page 5
WS1CT & WS1.25CT Manual
Installer Displays & Settings (1-99 Days Between Regeneration option)
Installer Displays & Settings (7 day option)
Step 1ID
- Access this mode by pressing SET and
▲
for approximately 3 seconds. The number
of days between regenerations may need to be varied based on usage and water conditions.
Step 2ID
- Set Regeneration Time Hour. Set the time for regeneration to start.
Press SET to go to the next step.
RETURN TO NORMAL MODE
Step 4ID
- Set number of Days between regeneration cycles. The allowable range is 1-99. Press
SET to go to Step 5ID. (This step will not appear if the 7-day clock option is selected.)
Step 3ID
- Set Regeneration Time Minutes. Press SET to go to the next step.
Step 1I7 -
Access this mode by pressing SET and
▲
for approximately 3 seconds. The number
of days between regenerations may need to be varied based on usage and water conditions.
Step 2I7-
Set Regeneration Time Hour. Set the time for regeneration to start.
Press SET to go to the next step.
Step 3I7 -
Set Regeneration Time Minutes. Press SET to go to the next step.
STEP 4I7
– Current Day of Week:
Set the current day of the week by using
▲
or
▼
(See chart at right for date codes).
Press SET to go to STEP 5I7.
(This step will not appear if the 99-day option is selected.)
Display
Day of Week
day 1
d1
Sunday
day 2
d2
Monday
day 3
d3
Tuesday
day 4
d4
Wednesday
day 5
d5
Thursday
day 6
d6
Friday
day 7
d7
Saturday
STEP 1ID
STEP 2ID
STEP 3ID
STEP 4ID
STEP 1I7
STEP 2I7
STEP 3I7
STEP 4I7
Step 5ID
- LCD Backlight Operation. Set the backlight to be normally ON or OFF. When set to
OFF, the backlight will go off after 5 minutes of no keypad activity. Press SET to exit Installer
Displays and Settings.
STEP 5ID