Water Right UltroWater Скачать руководство пользователя страница 2

TABLE OF CONTENTS

 

Page

SECTION I. 

INTRODUCTION ...................................................................................3

SECTION II. 

SPECIFICATIONS  ................................................................................4

SECTION III. 

PREPARATION .....................................................................................5

 

A.  Major System Components .............................................................5

 

B.  Tools Recommended for Installation ...............................................7

 

C.  Site Selection For Major System Components ...............................7

SECTION IV. 

INSTALLATION STEPS ........................................................................8

 

A.  Faucet with Water Quality Monitor Installation ................................8

 

B.  Feed Water Saddle Valve Installation ...........................................10

 

C.  Drain Clamp Installation ................................................................10

 

D.  R.O. Manifold Assembly Installation .............................................11

 

E.  Position the Drinking Water Holding Tank 

 

 

and Make the Final Hose Connections .........................................12

 

F.  Start Up .........................................................................................12

SECTION V. 

OPERATION AND MAINTENANCE ...................................................12

 

A.  Normal Operation ..........................................................................12

 

B.  Changing Modules ........................................................................13

 

C.  Changing the In-Line Activated Carbon Post Filter .......................14

SECTION VI. 

TROUBLE SHOOTING GUIDE ...........................................................16

EXPLODED VIEW AND PARTS LIST ..................................................................................18

CAUTION:

The Centers for Disease Control and Prevention (CDC) and the Environmental Protection Agency (EPA) have issued guidance to people with severely 

weakened immune systems who may want to take extra precautions to reduce the risk of infection with Cryptosporidium from drinking water. This 

guidance pertains to people with HIV/AIDS, patients receiving treatment for cancer, recipients of organ or bone marrow transplants, transplant patients 

taking immunosuppressive drugs, and persons who have congenital immunodeficiencies.
The EPA has stated that they do not know the significance of drinking water compared to other possible sources of Cryptosporidium to determine how 

most people become infected. The CDC-EPA guidance suggests that immunosuppressed individuals discuss their risks with their health care provider.
This drinking water system is tested and Certified by NSF International to NSF/ANSI Standard 58 for cyst reduction. It meets the NSF/ANSI standard of 

reducing at least 99.95%* of cysts (including Cryptosporidium), however, because this is not 100%, immunosuppressed individuals should take the extra 

precaution of boiling their drinking water. According to the CDC-EPA, bringing water to a rolling boil for one minute is the most certain approach for killing 

Cryptosporidium.
All individuals should take adequate precautions when changing the filter cartridges, including wearing protective gloves, to avoid direct contact with the 

exhausted cartridges.
*For complete specifications, refer to the Performance Data Sheet.

Содержание UltroWater

Страница 1: ...rtified by NSF International against NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet R O Drinking Water System Model No UltroWater INSTALLATION OPERATION S...

Страница 2: ...rtains to people with HIV AIDS patients receiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital...

Страница 3: ...supply to prevent excess reject water from going to drain when the unit is not producing water WATER QUALITY MONITOR The optional Water Quality Monitor has been integrated into the faucet base for ins...

Страница 4: ...is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influen...

Страница 5: ...manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing TYPICAL ULTROWATER UNDER SINK INSTALLATION DIAGRAM The Water Qua...

Страница 6: ...ne housing sediment CARBON MODULE BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper air gap must be created please check with local plumbing codes see exam...

Страница 7: ...n area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the moun...

Страница 8: ...ink Center punch the hole to provide a starting point for the drill Start with a smaller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch C...

Страница 9: ...K 3 8 POLYTUBE TO DRAIN CLAMP BLACK 1 4 POLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fi...

Страница 10: ...When you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard Steel or Brass Tubing supply line The supply line shoul...

Страница 11: ...filter changes Mark the two locations the bracket can be used as a template Install the screws and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRIC...

Страница 12: ...rds the manifold Take the remaining housing and insert housing O ring into its groove Engage and firmly tighten housing hand tight only Remove the plug labeled ACTIVATED CARBON from the underside of t...

Страница 13: ...rval for changing the modules not the R O Membrane is every 6 to 12 months Typical T F C Membrane life expectancy is three years Local conditions may dictate more frequent changes NOTE If the R O Memb...

Страница 14: ...tube out of the fitting 4 Firmly reconnect the polytubes to the new Post Filter Refer to Fig 5 5 Slowly open the Feed Water Saddle Valve 6 When water begins dripping out of the Faucet in the following...

Страница 15: ...15...

Страница 16: ...e check The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Hold...

Страница 17: ...mbing Dissolved gasses in the Feed Water Pretreat Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Product Water section Drain Water overflows at the Dispensing...

Страница 18: ...18 MADE IN USA Exploded View Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 19 18 15 16 21 Nitrate Nitrite Test Kit 22 Water Quality Test Kit for systems without the Water Quality Monitor...

Страница 19: ...4 S3010 Housing 15 R7078 Optional Water Quality Monitor w Probes and Cover 16 S2116 6 Drain Restrictor 60 GPD 227 lpd 17 S7125X Activated Carbon Module 18 S1405 1 4 3 8 Fitting Wrench 19 S3072 Wrench...

Страница 20: ...for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose service life depends on fe...

Отзывы: