PROBLEM
CAUSE
CORRECTION
1. Softener fails
to regenerate
A. electrical service to unit has been
interrupted
A. assure permanent electrical service
(check fuse, plug, pull chain or
switch)
B. timer is defective
B. replace timer
C. power failure
C. reset time of day
D. timer programming bad
D. check programming and reset
2. Hard water
A. bypass valve is open
A. close bypass valve
B. no salt in brine tank
B. add salt to brine tank and maintain
salt level above water level
C. injector screen plugged
C. clean injector screen
D. insufficient water flowing into
brine tank
D. check brine tank fill time and clean
brine line flow control if plugged
E. hot water tank hardness
E. repeated flushing of the hot water
tank as required
F. leak at distributor tube
F. make sure distributor tube is not
cracked, check “O” Ring and tube pilot
G. internal valve leak
G. replace seals and spacers and/or
piston
H. flow meter jammed
H. remove obstruction from meter
I. flow meter cable disconnected
I. check meter cable connection to
timer and meter
J. improper programming
J. reprogram the control for proper
regeneration type, inlet hardness,
capacity or flow meter size
3. Unit used too
much salt
A. improper salt setting
A. check salt usage and salt setting
B. excessive water in brine tank
B. see problem no. 7
C. improper programming
C. check programming, reset
4. Loss of water
pressure
A. iron buildup in line to water
conditioner
A. clean line to water conditioner
B. iron buildup in water conditioner
B. clean control head and increase
frequency of regeneration
C. inlet of control plugged due to
foreign material broken loose
from pipes
C. remove piston and clean
control head
5. Loss of
mineral
through
drain line
A. air in water system
A. assure that well system has proper
air eliminator control — check for
dry well condition
B. drain line flow control too large
B. check flow control —
change if needed
TROUBLESHOOTING GUIDE
: