background image

7

1

Push in grey collet to release tubing.

2

Tubing is secured in.

Push tubing straight in as far as it will go.

Grey Collet 

Tube

O-Ring

1

Pull tubing straight out.

2

To Attach Tubing 

To Release Tubing 

This product is outfitted with user friendly ‘Push In’ connectors.

Proper use of the connectors is shown in the diagrams.

It is most important that the tubing selected for use with these

connectors be of high quality, exact size and roundness, and with no
surface nicks or scratches. If it is necessary to cut the tubing, use a
plastic tubing cutter or sharp razor knife. Make a clean square cut. 

Should a leak occur at a ‘Push-In’ connector, the cause is usually

defective tubing. 

To Fix: • 

Relieve pressure

• Release tubing
• Cut off at least 1/4” from end.
• Reattach tubing
• Confirm connection is leak free.

‘Push-In’ Tubing Connector

Содержание CoolerMATE

Страница 1: ... 2001 CUNO Incorporated 98 9100 1101 Owner s Manual This Manual is for the Installation Operation and Maintenance of the WATER FACTORY SYSTEMS CoolerMATE Drinking Water Appliances ...

Страница 2: ...e 3 A Water Supply Connection 3 B Mounting the System 3 C Tubing Connections 4 D System Startup 4 IV System Maintenance 4 A Replacing Filter Cartridges 4 Installation Diagram 5 CM 1 CTO CM 2 CTO CM 2 Lead Plus 5 CMF 350 DWS 6 CMR 350 DWS 6 Push In Connectors 7 2 Not performance tested or certified by NSF ...

Страница 3: ...states that prohibit the use of saddle type valves Using self piercing saddle valve or other suitable assembly connect to the nearest cold water supply Refer to enclosed instructions for saddle valve if necessary B Mounting The System The CoolerMate filter system can be mounted to the back of most free standing converted bottled water coolers or inside specially designed POU coolers If necessary t...

Страница 4: ...nnector cut the tubing and install the in line ball valve provided It should be located so that it cannot be stepped on or crushed behind the cooler D System Start Up 1 Check that all connections are secure 2 Turn on primary feed valve at water supply and check for leaks If any leaks are noted turn off valve and correct before proceeding If a leak occurs at a Push In plastic fitting refer to speci...

Страница 5: ...l plumbing codes for any restrictions that may apply Massachusetts CMR 248 strictly prohibits the use of saddle type valves The feedwater connection must conform to applicable plumbing codes CoolerMATE Installation Diagram Models CM 1 CTO CM 2 CTO CM 2 Lead Plus 5 To Cooler Outlet Fitting with Flow Control Feedwater Inlet Ball Valve From Feedwater Source To Cooler Outlet Fitting with Flow Control ...

Страница 6: ... New Hampshire North Dakota Ohio Oregon and South Dakota Check your local plumbing codes for any restrictions that may apply Massachusetts CMR 248 strictly prohibits the use of saddle type valves The feedwater connection must conform to applicable plumbing codes 6 To Cooler Outlet Fitting with Flow Control Feedwater Inlet Ball Valve From Feedwater Source Model CMF 350 DWS To Cooler Outlet Fitting ...

Страница 7: ...the diagrams It is most important that the tubing selected for use with these connectors be of high quality exact size and roundness and with no surface nicks or scratches If it is necessary to cut the tubing use a plastic tubing cutter or sharp razor knife Make a clean square cut Should a leak occur at a Push In connector the cause is usually defective tubing To Fix Relieve pressure Release tubin...

Страница 8: ...CUNO Incorporated 400 Research Parkway Meriden CT 06450 USA Toll Free 1 800 733 1199 Worldwide 1 203 237 5541 Fax 1 203 238 8701 www waterfactorysystems com www cuno com ...