Winterization Procedures 

BrassMaster / BrassMaster Plus+ Series water softeners have been specially designed for use in 

seasonal residences. Storage should be in an environment where temperatures are maintained 

above freezing.  

Storage and Removal Procedures: 

1.  Complete a regeneration cycle by holding down the “Extra Cycle Button.” Allow the unit to 

complete a full regeneration cycle. 

2.  Turn bypass valve to the “Bypass” position. 

3.  Hold  down  the  “Extra  Cycle  Button”  to  go  back  into  the  regeneration  mode.  Press  the 

“Extra  Cycle  Button”  to  advance  through  each  step  until  you  return  to  the  Time  of  Day.  

The pressure is now relieved in the system. 

4.  Disconnect power and drain line connections. 

5.  Remove stainless steel retainer tabs on the water softener side of the bypass valve with a 

standard screwdriver, and separate this connection. The water softener is now ready for re-

moval and storage. If the softener will be in freezing conditions, carefully remove the con-

trol  unit  and  place  in  a  warm  environment.  Keep  distributor  tube  in  place  at  all  times.  

Siphon water out of distributor tube.   

 

To re-install your BrassMaster / BrassMaster Plus+ unit,  

refer to “

Placing unit into service

” in the Installation / Operation Manual.

 

http://watercontrolinc.com/product-manuals/

 