Water Control Brassmaster Plus+ Скачать руководство пользователя страница 2

 

2

 

Specifications 

Feedwater   

! Do not use this system on water that is microbiologically unsafe or of unknown quality 

without adequate disinfection before or after the system. ! 

Minimum inlet pressure: 20 psig 
Maximum outlet pressure: 125 psig 
Minimum water temperature: 34 degrees F 
Maximum water temperature: 110 degrees F

 

 

Power 

Voltage: 120VAC 
Frequency: 60Hz 
Power consumption: 3 Watts Maximum 

 

Installation 

 

Location: Indoors (Protect from direct sunlight) 
Minimum ambient temperature: 34 degrees F 
Maximum ambient temperature: 122 degrees F 

 

Salt Capacity 

Cabinet models: 200lbs 

 

Two-Tank models: 300lbs 

 

Maximum Flow To Drain 

WBP27, WBPT27 (0.90 ft3 resin) – rated drain flow during regeneration – 2.0 gpm 
WBP35, WBPT35 (1.15 ft3 resin) – rated drain flow during regeneration – 2.0 gpm 
WBPT48 (1.5 ft3 resin) – rated drain flow during regeneration – 2.4 gpm 
WBPT60 (2.0 ft3 resin) – rated drain flow during regeneration – 4.0gpm 
 
 

 

This unit conforms to ANSI/NSF-44 for specific performance claims as verified and substantiated by 
test data.   

Содержание Brassmaster Plus+

Страница 1: ...Water Softening Systems Operation Maintenance Manual ...

Страница 2: ...n Location Indoors Protect from direct sunlight Minimum ambient temperature 34 degrees F Maximum ambient temperature 122 degrees F Salt Capacity Cabinet models 200lbs Two Tank models 300lbs Maximum Flow To Drain WBP27 WBPT27 0 90 ft3 resin rated drain flow during regeneration 2 0 gpm WBP35 WBPT35 1 15 ft3 resin rated drain flow during regeneration 2 0 gpm WBPT48 1 5 ft3 resin rated drain flow duri...

Страница 3: ...ne is drawn out of the brine cabinet and passed through the resin in a downward direction This rinses the resin and large amounts of sodium ions replace the hardness ions accumulated during service Slow Rinse After brine is completely removed from the brine cabinet into the resin tank the brine valve closes Water replaces any remaining brine from the resin flushing hardness ions removed from the r...

Страница 4: ...tioner inlet close it 2 Relieve water pressure in the conditioner by stepping the control into the backwash position momentarily Return the con trol to the service position 3 Unplug electrical cord from outlet 4 Disconnect brine tube and drain line connections at the injector body 5 Remove the two injector body mounting screws The injector and brine module can now be removed from the control valve...

Страница 5: ... tank and brine valve assembly J Salt bridge has formed J Refer to Breaking a Salt Bridge section in manu al K No water in brine tank K Ensure safety float is not stuck L Unit is plumbed backwards L Check that the unit is plumbed correctly M Water hardness has increased or is set incorrectly M Retest hardness and change settings N Water pressure is too low N Line pressure must be at least 20psi 3 ...

Страница 6: ... is plugged B Clean or replace injectors C Improper programming C Check programming and reset as needed D Line pressure is too low D Increase line pressure line pressure must be at least 20psi at all times 10 Drain Flows Continuously A Foreign material in control A Remove piston assembly and inspect bore re move foreign material check control in various ports 12 Loss of capacity A Increased raw wa...

Страница 7: ...7 Water Softener System Parts List Please contact Water Control CorporaƟon or your dealer for parts availability ...

Страница 8: ...alve Brine Tank Two Tank models Brine Tank Cabinet Models 15135 1 36523211 60002 Brine Well Air Check RT935 RT940 RT1035 RT1044 RT1054 RT1248 Resin Tank Model WBP27 Resin Tank Model WBPT27 Resin Tank Model WBP35 Resin Tank Model WBP35 Resin Tank Model WBPT48 Resin Tank Model WBPT60 60795 00 PE58 PE38 Distributor Assembly Drain Line Brine Line WRES1 Resin R8X See spec sheet for quantity ...

Отзывы: