Water Control Corporation MEGAbite BRASSMASTER Скачать руководство пользователя страница 3

 



Flush the MEGAbite filter with water: 

Locate the nearest cold water faucet tap and open 

it. If there is a water softener installed downstream of the MEGAbite, close its bypass valve 

until this step is completed. Slowly open MEGAbite bypass valve and let water run to the 

open faucet tap until it runs clear. This will flush any media residual from the filter and pre-

pare the unit for service. Re-open water softener bypass (if installed). 

 

Start-Up Procedure  

Setting current time of day 

Setting Current Time / Day  

 

1.  Press either the Up or Down buttons to adjust current time of day by one digit. Push and 

hold either up or down set button to adjust current time of day display by several digits.  

Placing unit into service 

Normal 

Operation 

Mode Icon 



While in service, the Data Display alternates between time of day, 
volume remaining or days to regeneration. 



The Flow Indicator flashes when outlet flow is detected. 



The Faucet Icon flashes if a regeneration cycle has been queued. 

Содержание MEGAbite BRASSMASTER

Страница 1: ...Video Library https watercontrolinc com residential technical support residential technical videos BrassMaster technical videos demonstrate how to set up or remove the control module Replacement cont...

Страница 2: ...d bypass valve Overheating may cause damage to valve Turn supplied bypass valve to Bypass position and make connections to household water lines Leave unit in Bypass position until startup procedure 3...

Страница 3: ...service Re open water softener bypass if installed Start Up Procedure Setting current time of day Setting Current Time Day 1 Press either the Up or Down buttons to adjust current time of day by one di...

Страница 4: ...ity without disinfection before or after the system User programming User Programming Mode Steps Refer to chart above for user mode indications 1 Press the Up and Down buttons for five seconds while v...

Страница 5: ...iltration perfor mance Another infrequent issue can be the malfunction of the water inlet check valve due to fowling with dirt and debris Cleaning and unplugging a dirty air injector or an inlet check...

Страница 6: ...te Please contact your dealer or Water Control Corporation for module support For factory module support contact Water Control Corporation 7150 143rd Ave NW Ramsey MN 55303 Phone 1 866 405 1268 Fax 76...

Страница 7: ...ISCLAIMS ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHAT IS NOT COVERED BY THESE WARRANTIES 1 Conditions and damag...

Страница 8: ...8 Water Control Corporation 7150 143rd Ave NW Ramsey MN 55303 Phone 1 866 405 1268 Fax 763 427 5665 www watercontrolinc com 1221...

Отзывы: