TROUBLESHOOTING CHECKLIST 

(CAUTION: SHUT OFF POWER TO PUMP)

PROBLEM

POSSIBLE CAUSES

Pump does not run or hums.

  •  Line circuit breaker is off, or fuse is blown or loose.
  •  Water level in sump has not reached turn-on level as indicated in installation drawing.
  •  Pump cord is not making contact in receptacle.
  •  Float is stuck. It should operate freely in basin.
  •  If all of the above are OK, then the motor winding may be open.

Pump runs but does not deliver 
water.

  •  Check valve is installed backward. Arrow on valve should point in direction of fl ow.
  •  Discharge shutoff valve (if used) may be closed.
  •  Pump is air-locked. Start and stop several times by plugging and unplugging cord. Check for 

clogged vent hole in pump case.

  •  Impeller or volute openings are fully or partially clogged. Remove pump and clean.
  •  Inlet holes in pump base are clogged. Remove pump and clean the openings.
  •  Vertical pumping distance is too high. Reduce distance or resize pump.

Pump runs and pumps out 
sump, but does not stop.

  •  Float is stuck in up position. Be sure fl oat operates freely in basin.
 • Defective 

fl oat switch. Replace with fl oat switch RSMA for R2SA, R3S and R5S-1.

  •  Defective vertical switch. Replace with vertical switch RVS for R3V and R5V.

Pump runs but delivers only a 
small amount of water.

  •  Pump is air-locked. Start and stop several times by plugging and unplugging cord. Check for 

clogged vent hole in pump case.

  •  Vertical pumping distance is too high. Reduce distance or resize pump.
  •  Inlet holes in pump base are clogged. Remove pump and clean the openings.
  •  Impeller or volute openings are fully or partially clogged. Remove pump and clean.
  •  Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. 

Remove pump and clean.

Fuse blows or circuit breaker 
trips when pump starts.

  •  Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. 

Remove pump and clean.

  •  Motor stator may be defective.
  •  Fuse size or circuit breaker may be too small. Must be 15 amps.
  •  Impeller or volute openings are fully or partially clogged. Remove pump and clean.

Motor runs for a short time, 
then stops.

  •  Inlet holes in pump base are clogged. Remove pump and clean the openings.
  •  Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. 

Remove pump and clean.

  •  Motor stator may be defective.
  •  Impeller or volute openings are fully or partially clogged. Remove pump and clean.

NOTES:

3

Содержание R5V

Страница 1: ...iday 7AM to 5 PM EST www waterace com INSTALLATION MANUAL Pgs 1 4 SUBMERSIBLE SUMP PUMPS POMPES DE PUISARD SUBMERSIBLES MANUEL D INSTALLATION Pgs 5 8 MANUAL DE INSTALACI N Pgs 9 13 BOMBAS DE SUMIDERO...

Страница 2: ...V and made of plastic fiberglass or concrete 8 The following may cause severe damage to pump and will void warranty Using an extension cord Cutting off the ground pin or using an adapter fitting Worki...

Страница 3: ...cle Minimum height of 4 feet above floor Discharge piping can be PVC or galvanized steel 1 1 2 for R2SA R3S R3V R5S 1 R5V The head vertical distance to discharge should not exceed values shown in char...

Страница 4: ...A for R2SA R3S and R5S 1 Defective vertical switch Replace with vertical switch RVS for R3V and R5V Pump runs but delivers only a small amount of water Pump is air locked Start and stop several times...

Страница 5: ...or service including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for...

Страница 6: ...osse d puisement doit tre a r e conform ment aux normes locales de plomberie Les pompes d puisement Water Ace ne sont pas con ues et ne doivent pas tre install es dans des endroits consid r s comme da...

Страница 7: ...ent de la pompe 1 1 2 po pour mod les R2SA R3S R3V R5S 1 et R5V TAPE 1 TAPE 2 TAPE 3 TAPE 4 TAPE 5 Sur l adaptateur collez un morceau de 15 po 38 1 cm de tuyau en PVC Utilisez un tuyau de diam tre app...

Страница 8: ...ueux Remplacez le par un interrupteur vertical RVS mod le R3V et R5V La pompe fonctionne mais avec un d bit tr s faible Une poche d air bloque la pompe Faites la arr ter et d marrer plusieurs fois en...

Страница 9: ...s y limiter aux produits ayant subi des pannes de fonctionnement caus es par la corrosion la rouille ou par des corps trangers qui se seraient introduits dans le syst me ou aux produits ayant fonctio...

Страница 10: ...la bomba deber limpiar el dep sito del sumidero de agua escombros o sedimentos ADVERTENCIA Deber ventilar el dep sito del sumidero tal y como lo establezcan los c digos locales sobre plomer a Las bomb...

Страница 11: ...flujo de agua apuntando en la direcci n opuesta a la bomba Ponga la bomba dentro del dep sito Coloque una abrazadera en el tubo de descarga y los accesorios de PVC que necesite para fijarlos al extre...

Страница 12: ...i n a tierra Altura m nima de 1 22 metros por encima del piso Interruptor del flotador M nimo de 30 5 cm APV 115 M nimo de 35 5 cm AP 2SA AP 115 AP 165 La tuber a de drenaje podr ser de PVC o de acero...

Страница 13: ...3S y R5S 1 Interruptor vertical defectuoso Reempl celo con el interruptor vertical RVS para el modelo R3V y R5V La bomba funciona pero bombea s lo una peque a cantidad de agua Es posible que se haya f...

Страница 14: ...stalaci n operaci n mantenimiento o almacenamiento inadecuados ni tampoco debido a aplicaciones usos o servicios que no sean normales incluyendo pero sin limitarse a fallas operacionales provocadas po...

Отзывы: