Water Ace R106 Скачать руководство пользователя страница 2

WA-25581A037

IMPORTANT INSTRUCTIONS BEFORE INSTALLATION

Failure to follow these instructions may cause serious bodily injury and/or property damage.

OPERATION INSTRUCTIONS

Add 1/2 teaspoon of light oil to pump inlet 
and outlet to aid priming. Attach suction hose 
provided to pump inlet. Attach garden hose to 
pump outlet. There must be a gasket in place 
to ensure that these connections are airtight, 
otherwise the pump will not prime.

STEP

1

WARNING:  To reduce risk of electrical shock, connect 
only to a properly grounded grounding-type receptacle.  
Read instructions before installing pump. This pump has 
not been investigated for use in swimming pool areas.

1. Before servicing your pump, BE CERTAIN pump power 
source is disconnected.

2. The Electric Sponge comes with a grounding conductor 
and a 3-prong ground-type plug. For maximum safety, plug 
into a 3-prong ground-type receptacle or extension cord. 
Extension cord thickness should equal or exceed pump power 
cord thickness.

3. Voltage of power supply must match the voltage of the 
pump. 

The R106 operates on 115V AC, 60 Hz only. The 

R107 operates on 12V DC only.

4. Pump operation will be seriously hindered or prevented if 
the inlet hose is over 15 feet long or if the vertical pumping 
distance exceeds 10 feet.

5. 

WARNING:

 The Electric Sponge is NOT a submersible 

pump. Keep pump and all power cords away from liquid.  
Also, the R107 pump (DC voltage) becomes very hot during 
operation. Do not handle the R107 during operation.

6. At times, an overload due to overheating, low voltage, 
jammed impeller, etc. may shut the pump off. Unplug the 
pump and wait at least ten minutes. The pump will cool and  
automatically reset. (115V model)

7. Packed with your pump are the following replacement 
parts: impeller, wear plates, O-ring, shaft seal, and two 
brush assemblies. See page 2 replacement instructions.

8. The following may cause severe damage to pump and will 
void warranty:
• Cutting off plug ground pin or using an adapter fi tting.
• Working on pump while plugged in.
• Pumping fl ammable or corrosive liquids.
• Running pump continuously for more than 1-1/2 hours.

Place the open end of inlet hose below water 
surface. The suction adapter may be used to pump 
shallow water or water with large particles. If using 
the suction adapter, connect the inlet hose to the 
suction adapter. The adapter is designed to accept 
the male end of a garden hose. Place the adapter 
near to the middle of the water to be pumped.  

STEP

2

Examine the inlet and outlet hoses to ensure there 
are no blockages or kinks or bends. The inlet hose 
should be no longer than 15 feet, and the vertical 
pumping distance should not exceed 10 feet.

STEP

3

COMPLETE PUMP SETUP

To Power

Source

Pump

Inlet Hose

Outlet Hose

(Not Included)

Suction Adapter 

Usage Optional

The Electric Sponge comes complete with pump,
replacement parts, 3/4" x 6' garden hose, and suction 
adapter. The R107 has color-coded battery clips for

With pump in a dry location, connect it to the power 
source. R106: Plug into a 3-prong ground-type AC 
receptacle. R107: Connect RED battery clip to the 
Positive terminal of a 12 volt battery and connect BLACK 
clip to Negative terminal, or any grounded object. Keep 
battery clip wires away from moving parts or hot spots 
of an engine. The setup should look like the drawing 
below. If pump fails to deliver water, disconnect from 
power source and repeat steps 1–4, or try lifting hose to 
aid in priming pump.

STEP

4

12V DC operation; the R106 has a 3-prong ground-type plug 
for 115V AC operation. The Electric Sponge may be used with 
or without suction adapter.

1

Содержание R106

Страница 1: ... OHIO 44805 1969 USA ONLY CONSUMER HOT LINE 1 800 942 3343 Monday Friday 7AM to 5 PM EST www waterace com INSTALLATION MANUAL Pgs 1 5 MULTI PURPOSE PUMPS POMPES POLYVALENTES MANUEL D INSTALLATION Pgs 6 9 MANUAL DE INSTALACIÓN Pgs 10 13 BOMBAS DE USO MÚLTIPLE WA 25581A037 Rev 12 20 05 ...

Страница 2: ...cked with your pump are the following replacement parts impeller wear plates O ring shaft seal and two brush assemblies See page 2 replacement instructions 8 The following may cause severe damage to pump and will void warranty Cutting off plug ground pin or using an adapter fitting Working on pump while plugged in Pumping flammable or corrosive liquids Running pump continuously for more than 1 1 2...

Страница 3: ...nerally good for the life of the pump If the seal leaks it is usually because the pump has handled abrasive liquids If the motor shaft is scored deep grooves the complete pump must be replaced Remove and inspect impeller parts as specified in the impeller replacement instructions Replace worn parts Remove two pump body mounting screws and slide pump body from motor Pry out seal retaining ring and ...

Страница 4: ... are worn See replacement instructions on page 2 Pump runs but stops 115 volt AC models only Motor has overheated motor overload trips out due to motor overload condition NOTE Overload protector will automatically reset about 10 minutes after tripping Disconnect from power supply and allow to cool Pump outlet hose is plugged or kinked Remove obstruction or kink Impeller is jammed with foreign mate...

Страница 5: ...ion use or service including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to WATER ACE as soon as possible after the discovery of any alleged defect WATER ACE will s...

Страница 6: ... tout liquide En outre la pompe R107 courant continu devient très chaude lorsqu elle fonctionne Vous ne devez donc pas manipuler une pompe R107 qui tourne 6 Il est possible que la pompe soit parfois arrêtée par une surcharge attribuable à une surchauffe une tension trop faible un impulseur engorgé etc Dans un tel cas débranchez la pompe et attendez au moins dix minutes La pompe peut alors refroidi...

Страница 7: ...a bague de retenue du joint de scellée et poussez le joint usé par l intérieur du corps de pompe Lubrifiez le nouveau joint avec une huile légère enfoncez le dans le corps de la pompe avec la lèvre vers l extérieur du moteur et enfoncez la bague de retenue du joint de scellée Remontez les composants de l impulseur dans le corps de la pompe Faites glisser le corps de la pompe sur le moteur en vous ...

Страница 8: ...laissez l équipement refroidir Le tuyau de refoulement de la pompe est bouché ou pincé Enlevez l obstruction ou le pli Des corps étrangers bloquent l impulseur Voir les instructions de remplacement en page 7 Il n est pas nécessaire de remplacer l impulseur s il n est pas endommagé Le moteur gronde mais il ne tourne pas puis il s arrête Des corps étrangers bloquent l impulseur Voir les instructions...

Страница 9: ...ns s y limiter aux produits ayant subi des pannes de fonctionnement causées par la corrosion la rouille ou par des corps étrangers qui se seraient introduits dans le système ou aux produits ayant fonctionné à des pressions dépassant les pressions maximales recommandées Toute demande de service au titre des présentes garanties devront être faites en retournant le produit défectueux au détaillant ou...

Страница 10: ...iente directa se calienta mucho durante su funcionamiento No manipule la bomba R107 durante su funcionamiento 6 En algunas ocasiones se podría apagar la bomba debido a una sobrecarga por sobrecalentamiento bajo voltaje un impulsor atascado etc Desenchufe la bomba y espere al menos diez minutos La bomba se enfriará y se reestablecerá automáticamente Modelo de 115 voltios 7 Las siguientes piezas de ...

Страница 11: ...sello y empuje el sello desgastado del vástago desde el interior del vástago de la bomba Lubrique el sello nuevo con aceite ligero empújelo dentro la carcasa de la bomba con el reborde viendo en dirección opuesta al motor y empuje el anillo de retención del sello hacia adentro Vuelva a ensamblar las piezas del impulsor dentro de la carcasa del la bomba Deslice la carcasa de la bomba por el vástago...

Страница 12: ...rgas del motor debido a una condición de sobrecarga del mismo NOTA el dispositivos de protección contra sobrecargas se reestablecerá automáticamente después de 10 minutos de haberse desconectado Desconecte del suministro eléctrico y permita que se enfríe La salida de la manguera está obstruida o está pinchada Elimine la obstrucción o la pinchadura El motor zumba pero no gira y eventualmente se apa...

Страница 13: ...una instalación operación mantenimiento o almacenamiento inadecuados ni tampoco debido a aplicaciones usos o servicios que no sean normales incluyendo pero sin limitarse a fallas operacionales provocadas por corrosión herrumbre u otros materiales extraños en el sistema o un funcionamiento a presiones que excedan los máximos recomendados Las solicitudes de servicio bajo esta garantía se deberán rea...

Отзывы: