background image

Danger

 

Danger

 

Danger

 

A1(Green) 

B1(Green/White) 

AC adaptor 

Light sensor 

    

Wide  Dynamic  Range  Camera 

 

WAT-233 

 

Operation Manual 

 

This  Operation  Manual  covers  safety,  camera  functions,  installation  and  the 
correct  operating  procedure  for  the  WAT-233.  First,  we  ask  you  to  read  this 
Operation Manual thoroughly, then install and operate the WAT-233 as advised. 
In addition, for future reference, we also advise safekeeping of this manual. 

 

Please contact the distributor or dealer from which the WAT-233 was purchased, 
if you do not understand the installation, operation or safety instructions laid out 
in  this  manual.  Not  understanding  the  contents  of  the  Operation  Manual 
sufficiently may cause damage to the camera. 

 

    

    

Guide to the Safety Symbols

                 

                 

                 

                 

 

 
 

The definitions of the symbols used in this operation manual are: 

 

When you do not adhere to or take notice of the “Danger” sign, it 
may lead to a serious accident such as death or injury caused by 
fire or electric shock. 

 

When you do not adhere to or take notice of the “Warning” sign, it 
may cause severe damage such as a physical injury. 

 

When you do not adhere to or take notice of the “Caution” sign, it 
may incur injury and cause damage to peripheral objects in the 
immediate surroundings. 

 

   

Cautions for Safety

           

           

           

           

         

       

       

       

       

     

    

The WAT-233 is designed to be used safely; however, if not used safely, it may 
lead to a physical accident caused by fire and electric shock. Therefore, please 
keep and read the “Cautions for safety” below for protection against accidents. 

 

 

Do not disassemble and/or modify the WAT-233.

 

 

    

Do not operate the WAT-233 with wet hands.

    

    

         

    

 

 

Use a stabilized power adaptor designed for DC+12V

±

±

±

±

10%, 

with a current capacity of more than 250mA for the WAT-233. 

The recommended voltage is DC+12V

±

10% 

 

Do not expose the WAT-233 to wetness or high moisture 

conditions. 

The WAT-233 is designed and approved for indoor use only. The 
WAT-233 is not water-resistant or waterproof. If the location of the 
camera is outdoors or in an outdoor like environment, we 
recommend that you use an outdoor camera housing. 

 

Protect the WAT-233 from condensation. 

Keep the WAT-233 dry at all times during storage and operation.

 

 

Should the camera not work properly, switch off the power 
immediately. Then check the camera according to the “Problems 
and Trouble shooting” section.

 

 

 

 

Avoid the striking of hard objects or dropping the WAT-233. 

The WAT-233 uses high quality electrical parts and precision 
components.

 

 

Do not connect any power supply directly to the video out 

terminal of the unit.

               

               

               

               

 

Do not connect the WAT-233 with any monitor using a video/power 
single transmission terminal. The WAT-233 is not designed for use 
with  this  type  of  equipment.  We  also  advise  you  to  read  the 
operation  manual  of  the  monitor  you  plan  to  use  before  any 
connections are made.

 

 

Do  not  install  the  WAT-233  in  a  position  subject  to  direct 

sunlight. 

Sunlight shinning directly onto the WAT-233 lens can cause 
damage to the CCD.

     

         

 

Select a stable place for installation of the WAT-233. 

Use  a  support  of  durable  strength  around  an  installation  position 
on a ceiling or wall when a camera stand or tripod is used.

 

 

Do not move the WAT-233 with the cables connected.

 

 

Before moving the WAT-233, always remove the video cable and 
power cable from the rear of the camera first.

 

 

Avoid using the WAT-233 near any strong electro- 
magnetic field. 

After installing into main equipment, if the WAT-233 is exposed to 
electromagnetic waves causing the monitored image to become 
distorted, we recommend the camera be shielded by appropriate 
protective casing.

    

    

Problems and Trouble Shooting

                                             

                                             

                                             

                                             

 

 
 

If any of the following problems occur when using the WAT-233,   

    

 

An optimal picture cannot be obtained, after checking that all the cables and 

connections are correctly in place

 

 

 

Smoke or any unusual odor emerges from the WAT-233 

 

• 

An  object  becomes  embedded  or  a  quantity  of  liquid  seeps  into  the  camera 
housing 

 

• 

More than the recommended voltage or/and amperage has been applied 
to the WAT-233 by mistake 

 

• 

Anything unusual occurring to any equipment connected to the WAT-233

 

    

Disconnect the camera immediately according to the following procedures: 

    

Switch off the main power supply to the camera.

   

 

 

Remove the power and video cables connected to the WAT-233. 

 

Contact the distributor or dealer from which the WAT-233 was purchased.

 

 

    

About EMC                             

                 

                 

                 

                 

 

 
 

The WAT-233 is in conformity with EMC test standards carried out by authorized 
organizations in Japan.

   

 

 

 

NTSC

   

FCC Part15 class B

   

 

P

 

A

 

L

   

 

EN61000-6-3/EN50130-4

 

 

Please use an auxiliary power supply (eg: UPS) to this camera to comply with 
EN50130-4 of EMC standards. 

 

Do not modify the WAT-233. A modified camera may not conform 
to EMC test standards. 

    

    

Contents   

                             

                             

                             

                             

 

           

           

           

           

 

 
 

Using the contents figures below, check to make sure all parts are present before 
use. 

 

    

    

Description of Parts

                                             

                                             

                                             

                                             

 

 

IMAGE SENSOR FRONT FACE 

The light receiving face of the image sensor 

(Dirt, water or oil deposits on the image sensor will cause an unclear picture on 
the  monitor.  Attach  the  lens  cap  to  protect  the  lens  and  the  CCD  from 
contamination and damage.) 

 

LENS MOUNT 

Mount for the lens (CS-mount) 

FINE FOCUS ADJUSTMENT SCREWS

 

There are 3 hex. adjustment screws each placed at intervals of 120

for fine   

focusing of the lens.

 

 

AUTO-IRIS SOCKET 

This socket is for the video/DC auto-iris lens cable connector.   

(Video/DC: Auto selected by the camera) 

 

TRIPOD MOUNTING SCREW HOLES 

Mounting holes for stands. The size of these threads are 1/4”, 20 threads, 4.5

±

0.2mm, which is the same as any standard camera tripod (U1/4”). 

 

VIDEO OUT (BNC) 

The terminal for composite video signal output 

 

I/O CONNECTOR 

The control terminal for the RS-232, ALARM and infrared cut filter changer. 

 

Y/C OUT 

The terminal for Y/C signal output.

 

 

POWER IN 

The terminal designed for connection with the DC-plug of the power adaptor. 

 

OSD(On Screen Display) CONNECTOR 

The terminal designed for connection with the remote control for setting   

the functions on the screen. 

 

OPERATION BUTTON 

The operation button for setting the functions on the screen. 

 

    

Power Supply             

                         

                         

                         

                         

   

    

 

 

Use  a  stabilized  power  adaptor  designed  for  DC+12V

±

10%,  with  a  current 

capacity of more than 250mA. 
Use  the  optional  DC  plug  if  the  shape  or  polarity  of  the  DC  plug  of  the  power 
adaptor to  be  used  is  not compatible  with the camera  (See the drawing  on  the 
right below). 

 

 

                                             

 

The wiring of the connector must be exact. 
Be  careful  not  to  touch  the  other  terminal  while  wiring. 
Protect  the  wiring  portion  by  using  insulation  tape  after 
wiring.  If  the  above  care  and  attention  is  not  adhered  to, 
damage to the WAT-233 and power adaptor may occur and 
may also cause fire. 

    

    

Auto-iris Lens                                                   

                           

                           

                           

                           

 

 

Before connecting the auto-iris lens, please make sure that the pin configuration 
is correct  by confirming  with  the  following  table. If the  configuration  of  your  iris 
connector  is  different  from  the  following,  the  plug  and  pins  will  need  to  be 
rewired. 

 

Pin No. 

EIAJ Video 

Auto-iris Lens 

Arrangement 

EIAJ DC 

Auto-iris Lens 

Arrangement 

 

Power 

Control

 

 

 

Not used 

Control

 

 

 

Iris signals 

Drive

 

 

 

Common (GND) 

Drive

 

 

    

    

Mechanical Back                                               

                           

                           

                           

                           

 

 

Mechanical Back(M.B) is the projection   
from the lens mount to the camera.   
Use a lens with a mechanical back that 
is less than 5.0mm to the WAT-233.

 

 
    
    
    
    

    

Set-up and Operation

                                 

                                 

                                 

                                 

 

 

1) Ensure that the power to the WAT-233 and the peripheral equipment is   

turned off before making any connections. 

 

2) Remove the lens mount cap from the WAT-233 and attach the CS- 

mount lens. Use the optional C-mount adaptor (34CMA-R) when a C-mount 
lens is used.   

 

3) Connect the iris control cable to 

AUTO-IRIS SOCKET on the WAT- 

233 when an auto-iris lens is being used. 

 

4) Connect 

VIDEO OUT on the WAT-233 with the monitor, using a   

coaxial cable with 75

Ω

  impedance, such as an RG-59 or an RG-6/U.   

If  the  monitor  has  an  S-terminal,  high  resolution  imaging  is  possible  by 
connecting with 

Y/C OUT. 

The 

Y/C OUT can be used together with the 

VIDEO OUT. 

Select a monitor with the same television system as the WAT-233 NTSC or 
PAL. A monitor with more than 700TV lines is recommended. 

5) Insert the power plug of the power adaptor into 

POWER IN on the   

back panel of the WAT-233. Confirm that the power adaptor is not connected 
to the power supply before insertion of the power plug into 

POWER IN. 

 

6) Turn on the power to the WAT-233, monitor and all other allied   

equipment. When a picture cannot be obtained on the monitor, or a problem 
occurs,  check  and  follow  the  procedure  mentioned  in  the

Problems  and 

Trouble Shooting

section. 

 

7) After following the procedure below and the picture is still out of focus, open 

the  iris  fully  and  loosen 

FINE  FOCUS  ADJUSTMENT  SCREWS  with  the 

hex. wrench and move the lens forwards until a clear picture is obtained. 

 

Manual Lens 

Adjust  the  focus  and  iris  to  the  best  position

 

on the lens. 

Video Auto-iris Lens 

Adjust  the  focus  on  the  lens/camera,  then 
adjust the focus on the lens. . 

DC Auto-iris Lens 

Adjust the iris level on the camera, then adjust 
the focus on the lens.   

 

  

 

When using a DC Auto-Iris lens, adjustments to the iris level can be done 
by  changing  the  level  in  the  OSD  menu  by  use  of  the  remote  control 
(RC-01) included. Please refer to the User’s Manual. 

 

8) When detailed settings are required or an adequate image is not   

obtained, connect the remote control(RC-01) to 

OSD(On Screen   

Display) CONNECTOR, then set the functions on the screen by   

OPERATION BUTTON. 

 

9) When controlling the RS-485, alarm output and infrared cut-filter   

changer, connect to 

I/O CONNECTOR after wiring using the attached   

cable. See the pin configuration as follows.   

 
 
 
 
 
 
 
 
 

 

PIN 
No. 

Cable 

color 

Title 

Function 

A1 

Green 

D/N EXT CTL(+) 

B1 

Green/ 

White 

D/N EXT CTL(-) 

DAY/NIGHT external control 

(Photo coupler input, Polar) 

A2 

Purple 

D/N STATE OUT(1) 

B2 

Purple/ 

White 

D/N STATE OUT(2) 

DAY/NIGHT state output 

(Photo MOS relay output, Nonpolar) 

A3 

Orange 

ALARM (1) 

B3 

Orange/ 

White 

ALARM (2) 

Motion detection alarm out 

(Photo MOS relay output, Nonpolar) 

A4 

NC 

 

B4 

Black 

GND 

Camera GND   

A5 

Gray 

RXD (+) 

Data input   

from the camera side 

B5 

Gray/ 
White 

RXD (-) 

RS-485 

(non-isolated) 

Data input   

from the camera side 

 

External DAY/NIGHT control terminal 

 

When EXT mode DAY/NIGHT image setting is selected, the camera mode can 
be changed from DAY to NIGHT (IR-cut filter removed) by an applied voltage of 3 
to 12V between the terminals A1 and B1 (current value: 1mA at 3V and 6mA at 
12V).  By  connecting  a  light  sensor  as  indicated  in  the  diagram  below, 
DAY/NIGHT  modes  can  be  controlled  according  to  the  lighting  condition  of  the 
monitored  object.  Please  make  sure  the  electrical  polarity  is  correct  when 
connecting the cables.

 

 

 
 

 
 

 

 
 

 

Warning

DC+12V

COMMON(GND)

 

Caution

 

Warning

 

Caution

 

Warning

 

Caution

+

-

Отзывы: