background image

 

Page 

19

 of 

21

                                      

351 Ferrier Street • Markham, ON • L3R 5Z2 

PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186 

www.watchnetaccess.com / [email protected]

 

 

3.3.7 Board info 

 

 

 

Содержание WAC 1D2T MICRO/E

Страница 1: ...Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com WatchNET Access Integrated Security Management Software WAC 1D2T Micro Single Door Time Attendance Controller ...

Страница 2: ...g Diagram 8 2 4 RS485 Net Bus 10 2 5 TCP IP Network 10 Chapter3 Instructions 12 3 1 Clock Configuration 12 3 1 1 Edit Time 12 3 2 Card Configuration 13 3 2 1 Add Card 13 3 2 2 Delete Card 14 3 2 3 Del All Cards 15 3 3 System Configuration 15 3 3 1 Language Setting 15 3 3 2 Menu Password 16 3 3 3 Reader Settings 17 3 3 4 System Info Configuration 17 3 3 5 Network Configuration 18 3 3 6 Sleep Time 1...

Страница 3: ...to complete attendance The OLED screen will display time and staff ID information This system greatly improves the T A simplicity and offers cost saving on traditional tags When the WAC 1D2T MICRO works as an access controller the traditional keys are no longer needed Employees can enter their space by flashing authorized cards The WAC 1D2T MICRO can by itself control a door and both in and out re...

Страница 4: ...al while the OLED screen shows time and card number 2 1 Rex Button output 1 magnetic contact input 1 Wiegand 26 34 input output 2 auxiliary inputs 2 relay outputs 1 RS485 interface 1 door bell interface 3 Can connect to external Wiegand26 34 reader keypad reader included Entrance exit can be controlled by Card PIN or Card PIN 4 Customized OLED LOGO display menu with backlight showing the name and ...

Страница 5: ...te Frequency 125KHZ E EM 13 56MHZ M Mifare Read Range 3 15CM Outputs NC NO 30VDC 5A Power Supply 12VDC 10 200MA Dimension 117mm H x 86mm W x 22mm D 1 3 Application Mode 3 Application Modes Standalone Outdoor external reader indoor WAC 1D2T MICRO Indoor external reader outdoor WAC 1D2T MICRO Chapter2 Wiring Diagram 2 1 WAC 1D2T MICRO Appearance Figure 2 1 LED Green Blue Backlight Keypad Door bell C...

Страница 6: ...dicator Keypad NO Key Description NO Key Description 1 1 Numeral 1 7 7 Numeral 7 2 2 Numeral 2 8 8 Numeral 8 3 3 Numeral 3 9 9 Numeral 9 4 4 Numeral 4 10 0 Numeral 0 5 5 Numeral 5 11 Cancel Start 6 6 Numeral 6 12 Enter Confirm 2 2 Wiring Diagram Figure 2 2 Back of the reader J7 Reader signal output J2 Door bell J4 TCP IP interface J6 Door Contact Rex Button Auxiliary output J5 Reader interface J3 ...

Страница 7: ...con NO Connection Definition J1 1 GND Power supply J6 17 BUT Magnetic Rex Button Auxiliary output 2 12V 18 SEN J2 3 BELL Door bell 19 GND 4 BELL 20 IN1 J3 5 485 485 interface 21 IN2 6 485 22 GND J4 7 RX TCP IP interface J7 23 12V Reader signal output 8 RX 24 D0 9 TX 25 D1 10 TX 26 LED J5 11 12V External reader interface 27 GND 12 D0 28 BUZ 13 D1 J8 29 NC1 Relay output 14 LED 30 COM1 15 GND 31 NO1 ...

Страница 8: ...ectly connect to host PC via Ethernet port Customer can set all configurations when connected to host PC Moreover user authorization and exporting card events can also be done via AccessWatch3000 J5 External Reader Interfaces 12V External reader power supply Positive D0 Wiegand input D1 Wiegand output LED Indicator connector GND Ground BUZ Buzzer connector J6 Door Contact Rex Button Auxiliary Inpu...

Страница 9: ...et Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com Figure 2 4 Electronic Strike Lock Figure 2 5 Magnetic Lock Fail safe Figure 2 6 Cathode lock Fail secure ...

Страница 10: ...used to the device Figure 2 7 Twisted pair Twisted pair are used to connect controller to controller No GND is needed Series connection Terminals are connecting via series connection A multi bus RS485HUB is needed if customer needs parallel connection RS485 Single Point Ground If controller transmission line is with shielding or needs ground line then all controllers transmission line can be groun...

Страница 11: ...E 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com TCP IP Connector Figure 2 9 Sheet 2 2 Normal net cable to switch 图2 10 Crossed cable to PC Figure 2 11 RJ45 NO Connection 1 TX 2 TX 3 RX 6 RX 8 1 8 1 8 1 8 1 ...

Страница 12: ...cess com info watchnetinc com Chapter3 Instructions User Management PIN management Work mode and Time set are configured in the manage menu Menu structure is shown below Press 39 to enter manage menu when idle In the main menu works as cancel works as confirm 3 works as Up 9 works as down 3 1 Clock Configuration 3 1 1 Edit Time ...

Страница 13: ...Page 13 of 21 351 Ferrier Street Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com ...

Страница 14: ...Page 14 of 21 351 Ferrier Street Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com ...

Страница 15: ...Page 15 of 21 351 Ferrier Street Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com ...

Страница 16: ...Page 16 of 21 351 Ferrier Street Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com ...

Страница 17: ...Page 17 of 21 351 Ferrier Street Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com 3 3 4 System Info Configuration ...

Страница 18: ...Page 18 of 21 351 Ferrier Street Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com 3 3 5 Network Configuration 3 3 6 Sleep Time ...

Страница 19: ...Page 19 of 21 351 Ferrier Street Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com 3 3 7 Board info ...

Страница 20: ...Page 20 of 21 351 Ferrier Street Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com ...

Страница 21: ...Page 21 of 21 351 Ferrier Street Markham ON L3R 5Z2 PHONE 416 410 6865 TOLL FREE 1 866 331 3341 FAX 905 752 0186 www watchnetaccess com info watchnetinc com ...

Отзывы: